Ayyangar et al., 1993 - Google Patents

Experimental verification of a three‐dimensional dose calculation algorithm using a specially designed heterogeneous phantom

Ayyangar et al., 1993

Document ID
2926254777354522869
Author
Ayyangar K
Palta J
Sweet J
Suntharalingam N
Publication year
Publication venue
Medical physics

External Links

Snippet

A solid heterogeneous phantom made up of 25‐and 50‐mm cubes of materials with different electron densities was used to verify the accuracy of a three‐dimensional (3‐D) dose calculation algorithm. This algorithm uses 3‐D information obtained from contiguous CT …
Continue reading at aapm.onlinelibrary.wiley.com (other versions)

Classifications

    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/1048Monitoring, verifying, controlling systems and methods
    • A61N5/1075Monitoring, verifying, controlling systems and methods for testing, calibrating, or quality assurance of the radiation treatment apparatus
    • A61N2005/1076Monitoring, verifying, controlling systems and methods for testing, calibrating, or quality assurance of the radiation treatment apparatus using a dummy object placed in the radiation field, e.g. phantom
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/103Treatment planning systems
    • A61N5/1031Treatment planning systems using a specific method of dose optimization
    • A61N2005/1034Monte Carlo type methods; particle tracking
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N2005/1092Details
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/1001X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy using radiation sources introduced into or applied onto the body; brachytherapy
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/02Dosimeters
    • G01T1/026Semiconductor dose-rate meters

Similar Documents

Publication Publication Date Title
Arnfield et al. The impact of electron transport on the accuracy of computed dose
Wang et al. A patient‐specific Monte Carlo dose‐calculation method for photon beams
McNutt et al. Calculation of portal dose using the convolution/superposition method
Aspradakis et al. Experimental verification of convolution/superposition photon dose calculations for radiotherapy treatment planning
Bragg et al. Dosimetric verification of the anisotropic analytical algorithm for radiotherapy treatment planning
Popple et al. Comprehensive evaluation of a commercial macro Monte Carlo electron dose calculation implementation using a standard verification data set
Cheng et al. Systematic verification of a three‐dimensional electron beam dose calculation algorithm
Purdy Photon dose calculations for three-dimensional radiation treatment planning
Huyskens et al. Midplane dose determination using in vivo dose measurements in combination with portal imaging
Davidson et al. Heterogeneity dose calculation accuracy in IMRT: Study of five commercial treatment planning systems using an anthropomorphic thorax phantom
Masterson et al. Interinstitutional experience in verification of external photon dose calculations
Kontaxakis Maximum likelihood image reconstruction in positron emission tomography (PET):\sConvergence characteristics and stopping rules
Spirydovich et al. High density dental materials and radiotherapy planning: comparison of the dose predictions using superposition algorithm and fluence map Monte Carlo method with radiochromic film measurements
Wang et al. Experimental verification of a CT‐based Monte Carlo dose‐calculation method in heterogeneous phantoms
Samuelsson et al. Dose accuracy check of the 3D electron beam algorithm in a treatment planning system
Lewis et al. Use of Monte Carlo computation in benchmarking radiotherapy treatment planning system algorithms
Ayyangar et al. Experimental verification of a three‐dimensional dose calculation algorithm using a specially designed heterogeneous phantom
Ramsey et al. Dosimetric verification of two commercially available three‐dimensional treatment planning systems using the TG 23 test package
El-Khatib et al. Evaluation of lung dose correction methods for photon irradiations of thorax phantoms
McShan et al. Dosimetric verification of a 3‐D electron pencil beam dose calculation algorithm
Mayer et al. Two‐dimensional film dosimetry application in heterogeneous materials exposed to megavoltage photon beams
Linthout et al. Evaluation of dose calculation algorithms for dynamic arc treatments of head and neck tumors
El‐Khatib et al. Accuracy of lung dose calculations for large‐field irradiation with 6‐MV x rays
Kruszyna‐Mochalska et al. Development of a quasi‐humanoid phantom to perform dosimetric and radiobiological measurements for out‐of‐field doses from external beam radiation therapy
Galvin Calculation and prescription of dose for total body irradiation