Photon dose calculations for three-dimensional radiation treatment planningPurdy, 1992
- Document ID
- 13023791898560041280
- Author
- Purdy J
- Publication year
- Publication venue
- Seminars in radiation oncology
External Links
Snippet
I n the treatment of cancer with radiation, the radiation oncologist is faced with the problem of prescribing a treatment regime that either cures or controls the disease, but does not inflict serious complications to the patient. The difficulty of this task is illustrated by the dose …
- 238000004364 calculation method 0 abstract description 37
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/103—Treatment planning systems
- A61N5/1031—Treatment planning systems using a specific method of dose optimization
- A61N2005/1034—Monte Carlo type methods; particle tracking
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1048—Monitoring, verifying, controlling systems and methods
- A61N5/1075—Monitoring, verifying, controlling systems and methods for testing, calibrating, or quality assurance of the radiation treatment apparatus
- A61N2005/1076—Monitoring, verifying, controlling systems and methods for testing, calibrating, or quality assurance of the radiation treatment apparatus using a dummy object placed in the radiation field, e.g. phantom
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1048—Monitoring, verifying, controlling systems and methods
- A61N5/1049—Monitoring, verifying, controlling systems and methods for verifying the position of the patient with respect to the radiation beam
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N2005/1085—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy characterised by the type of particles applied to the patient
- A61N2005/1087—Ions; Protons
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1042—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy with spatial modulation of the radiation beam within the treatment head
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N2005/1085—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy characterised by the type of particles applied to the patient
- A61N2005/109—Neutrons
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N2005/1092—Details
- A61N2005/1095—Elements inserted into the radiation path within the system, e.g. filters or wedges
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1077—Beam delivery systems
-
- G—PHYSICS
- G21—NUCLEAR PHYSICS; NUCLEAR ENGINEERING
- G21K—TECHNIQUES FOR HANDLING PARTICLES OR IONISING RADIATION NOT OTHERWISE PROVIDED FOR; IRRADIATION DEVICES; GAMMA RAY OR X-RAY MICROSCOPES
- G21K1/00—Arrangements for handling particles or ionizing radiation, e.g. focusing or moderating
- G21K1/02—Arrangements for handling particles or ionizing radiation, e.g. focusing or moderating using diaphragms, collimators
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Purdy | Photon dose calculations for three-dimensional radiation treatment planning | |
Hogstrom et al. | Dosimetric evaluation of a pencil-beam algorithm for electrons employing a two-dimensional heterogeneity correction | |
Kawrakow et al. | 3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC) | |
Boellaard et al. | New method to obtain the midplane dose using portal in vivo dosimetry | |
Arnfield et al. | The impact of electron transport on the accuracy of computed dose | |
Neuenschwander et al. | MMC-a high-performance Monte Carlo code for electron beam treatment planning | |
Reynaert et al. | Monte Carlo treatment planning for photon and electron beams | |
Fippel et al. | Electron beam dose calculations with the VMC algorithm and the verification data of the NCI working group | |
Popple et al. | Comprehensive evaluation of a commercial macro Monte Carlo electron dose calculation implementation using a standard verification data set | |
WO1998052646A1 (en) | The evaluated teletherapy source library | |
Cheng et al. | Systematic verification of a three‐dimensional electron beam dose calculation algorithm | |
Sterpin et al. | Monte Carlo evaluation of the convolution/superposition algorithm of Hi‐Art™ tomotherapy in heterogeneous phantoms and clinical cases | |
Lujan et al. | Quantization of setup uncertainties in 3‐D dose calculations | |
Zhang et al. | Comprehensive evaluation and clinical implementation of commercially available Monte Carlo dose calculation algorithm | |
Hartmann-Siantar et al. | Lawrence Livermore National Laboratorys PEREGRINE project | |
Evans | Computerized treatment planning systems for external photon beam radiotherapy | |
US5418715A (en) | Method of electron beam radiotherapy | |
McCurdy et al. | Photon scatter in portal images: accuracy of a fluence based pencil beam superposition algorithm | |
Han et al. | A study of the shielding used to reduce leakage and scattered radiation to the fetus in a pregnant patient treated with a 6-MV external X-ray beam | |
Venables et al. | Three-dimensional distribution of radiation within the breast: an intercomparison of departments participating in the START trial of breast radiotherapy fractionation | |
Hasani et al. | A Monte Carlo evaluation of dose distribution of commercial treatment planning systems in heterogeneous media | |
Saroj et al. | Does fluence smoothing reduce the complexity of the intensity-modulated radiation therapy treatment plan? A dosimetric analysis | |
Ayyangar et al. | Experimental verification of a three‐dimensional dose calculation algorithm using a specially designed heterogeneous phantom | |
Harms et al. | Abutment of high energy electron fields | |
Seuntjens et al. | Comparison of measured and calculated dose distributions in lung after electron beam treatment of the chest wall |