Kandasamy et al., 2022 - Google Patents

Two-phase spray cooling for high ambient temperature data centers: Evaluation of system performance

Kandasamy et al., 2022

Document ID
8948611133242877
Author
Kandasamy R
Ho J
Liu P
Wong T
Toh K
et al.
Publication year
Publication venue
Applied Energy

External Links

Snippet

A lab-scale spray cooled rack system with a server and simulated heaters, operating with near-ambient temperature coolant of approximately 30° C, was developed for data center cooling application. This system has significant energy saving potential as it eliminates the …
Continue reading at www.sciencedirect.com (other versions)

Classifications

    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/20709Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
    • H05K7/20763Liquid cooling without phase change
    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/20709Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
    • H05K7/20718Forced ventilation of a gaseous coolant
    • H05K7/20745Forced ventilation of a gaseous coolant within rooms for removing heat from cabinets, e.g. by air conditioning device
    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/20218Modifications to facilitate cooling, ventilating, or heating using a liquid coolant without phase change in electronic enclosures
    • H05K7/20272Accessories for moving fluid, for expanding fluid, for connecting fluid conduits, for distributing fluid, for removing gas or for preventing leakage, e.g. pumps, tanks or manifolds
    • HELECTRICITY
    • H01BASIC ELECTRIC ELEMENTS
    • H01LSEMICONDUCTOR DEVICES; ELECTRIC SOLID STATE DEVICES NOT OTHERWISE PROVIDED FOR
    • H01L23/00Details of semiconductor or other solid state devices
    • H01L23/34Arrangements for cooling, heating, ventilating or temperature compensation; Temperature sensing arrangements
    • H01L23/46Arrangements for cooling, heating, ventilating or temperature compensation; Temperature sensing arrangements involving the transfer of heat by flowing fluids
    • H01L23/473Arrangements for cooling, heating, ventilating or temperature compensation; Temperature sensing arrangements involving the transfer of heat by flowing fluids by flowing liquids
    • HELECTRICITY
    • H01BASIC ELECTRIC ELEMENTS
    • H01LSEMICONDUCTOR DEVICES; ELECTRIC SOLID STATE DEVICES NOT OTHERWISE PROVIDED FOR
    • H01L23/00Details of semiconductor or other solid state devices
    • H01L23/34Arrangements for cooling, heating, ventilating or temperature compensation; Temperature sensing arrangements
    • H01L23/46Arrangements for cooling, heating, ventilating or temperature compensation; Temperature sensing arrangements involving the transfer of heat by flowing fluids
    • H01L23/467Arrangements for cooling, heating, ventilating or temperature compensation; Temperature sensing arrangements involving the transfer of heat by flowing fluids by flowing gases, e.g. air

Similar Documents

Publication Publication Date Title
Kandasamy et al. Two-phase spray cooling for high ambient temperature data centers: Evaluation of system performance
Khalaj et al. A Review on efficient thermal management of air-and liquid-cooled data centers: From chip to the cooling system
US9750159B2 (en) Pump-enhanced, immersion-cooling of electronic compnent(s)
US8934250B2 (en) Immersion-cooling of selected electronic component(s) mounted to printed circuit board
US8713957B2 (en) Thermoelectric-enhanced, vapor-condenser facilitating immersion-cooling of electronic component(s)
US8369091B2 (en) Interleaved, immersion-cooling apparatus and method for an electronic subsystem of an electronics rack
US8964390B2 (en) Sectioned manifolds facilitating pumped immersion-cooling of electronic components
CN107924896B (en) Cooling system for electronic equipment
US9061383B2 (en) Heat sink structure with a vapor-permeable membrane for two-phase cooling
JP5671659B2 (en) Cooling unit
US8934245B2 (en) Heat conveying structure for electronic device
US8184436B2 (en) Liquid-cooled electronics rack with immersion-cooled electronic subsystems
US9095942B2 (en) Wicking and coupling element(s) facilitating evaporative cooling of component(s)
US8345423B2 (en) Interleaved, immersion-cooling apparatuses and methods for cooling electronic subsystems
US20140071627A1 (en) Coolant drip facilitating partial immersion-cooling of electronic components
US10912229B1 (en) Cooling system for high density racks with multi-function heat exchangers
US20130105120A1 (en) Multi-fluid, two-phase immersion-cooling of electronic component(s)
US20110315355A1 (en) Immersion-cooling apparatus and method for an electronic subsystem of an electronics rack
Hnayno et al. Performance analysis of new liquid cooling topology and its impact on data centres
JP6565611B2 (en) Information processing device
Shrigondekar et al. Investigations on performance of single-phase immersion cooling system
US9095078B2 (en) Actively controlling coolant-cooled cold plate configuration
Wu et al. Full-scale two-phase liquid immersion cooing data center system in tropical environment
Shahi et al. A METHODOLOGY FOR THERMAL CHARACTERIZATION OF HIGH-POWER LIQUID-COOLED SERVERS
US20230180428A1 (en) High power density server with hybrid thermal management