[go: up one dir, main page]
More Web Proxy on the site http://driver.im/

Hnayno et al., 2022 - Google Patents

Performance analysis of new liquid cooling topology and its impact on data centres

Hnayno et al., 2022

View PDF
Document ID
5983122466395204943
Author
Hnayno M
Chehade A
Klaba H
Bauduin H
Polidori G
Maalouf C
Publication year
Publication venue
Applied Thermal Engineering

External Links

Snippet

A large amount of the energy consumed by data centres is related to the cooling demand. The use of optimised liquid cooling technology enables one to increase the water inlet temperature and the water temperature difference of a data centre. Accordingly, the energy …
Continue reading at www.sciencedirect.com (PDF) (other versions)

Classifications

    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/20709Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
    • H05K7/20718Forced ventilation of a gaseous coolant
    • H05K7/20745Forced ventilation of a gaseous coolant within rooms for removing heat from cabinets, e.g. by air conditioning device
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F1/00Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
    • G06F1/16Constructional details or arrangements
    • G06F1/20Cooling means
    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/20536Modifications to facilitate cooling, ventilating, or heating for racks or cabinets of standardized dimensions, e.g. 19-inch electronic racks
    • H05K7/20554Forced ventilation of a gaseous coolant
    • H05K7/2059Forced ventilation of a gaseous coolant within rooms for removing heat from cabinets, e.g. by air conditioning device
    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/20218Modifications to facilitate cooling, ventilating, or heating using a liquid coolant without phase change in electronic enclosures

Similar Documents

Publication Publication Date Title
Hnayno et al. Performance analysis of new liquid cooling topology and its impact on data centres
Nadjahi et al. A review of thermal management and innovative cooling strategies for data center
Ding et al. Principles of loop thermosyphon and its application in data center cooling systems: A review
Zhang et al. Recent advancements on thermal management and evaluation for data centers
Kandasamy et al. Two-phase spray cooling for high ambient temperature data centers: Evaluation of system performance
Li et al. Current status and future trends in data-center cooling technologies
Capozzoli et al. Cooling systems in data centers: state of art and emerging technologies
US7024573B2 (en) Method and apparatus for cooling heat generating components
US8934250B2 (en) Immersion-cooling of selected electronic component(s) mounted to printed circuit board
US9357675B2 (en) Pump-enhanced, immersion-cooling of electronic component(s)
US9095889B2 (en) Thermoelectric-enhanced air and liquid cooling of an electronic system
Tian et al. A combined cooling solution for high heat density data centers using multi-stage heat pipe loops
Gupta et al. Waste heat recovery in a data center with an adsorption chiller: Technical and economic analysis
Ling et al. Experimental investigation on the thermal performance of water cooled multi-split heat pipe system (MSHPS) for space cooling in modular data centers
He et al. Performance optimization of server water cooling system based on minimum energy consumption analysis
Xue et al. Data center energy conservation study utilizing loop heat pipes as a chip-level cooling technique and its industrial application
Shrigondekar et al. Investigations on performance of single-phase immersion cooling system
Lee et al. Numerical and experimental investigations on thermal management for data center with cold aisle containment configuration
He et al. Effects of different water-cooled heat sinks on the cooling system performance in a data center
Gao et al. Comparative analysis of different in row cooler management configurations in a hybrid cooling data center
Chen et al. Experimental research and energy effectiveness analysis on chip-level two-stage loop thermosyphon system for data centre free cooling
Shalom Simon et al. CFD analysis of Heat capture ratio in a hybrid cooled server
Amalfi et al. Design of passive two-phase thermosyphons for server cooling
Alkrush et al. Data Centers Cooling: A Critical Review of Techniques, Challenges, and Energy Saving Solutions.
Wu et al. Full-scale two-phase liquid immersion cooing data center system in tropical environment