Yang et al., 2004 - Google Patents

Performance of three air distribution systems in VOC removal from an area source

Yang et al., 2004

View PDF
Document ID
3515006936347105442
Author
Yang X
Srebric J
Li X
He G
Publication year
Publication venue
Building and Environment

External Links

Snippet

Building-related health complaints and symptoms represent a significant occupational health problem. Elevated concentrations of various types of indoor pollutants, frequently associated with inadequate ventilation, have been implicated as a potential cause. The …
Continue reading at www.academia.edu (PDF) (other versions)

Classifications

    • FMECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
    • F24HEATING; RANGES; VENTILATING
    • F24FAIR-CONDITIONING, AIR-HUMIDIFICATION, VENTILATION, USE OF AIR CURRENTS FOR SCREENING
    • F24F11/00Control or safety systems or apparatus
    • F24F11/0009Electrical control or safety systems or apparatus
    • F24F11/001Control systems or circuits characterised by their inputs, e.g. using sensors

Similar Documents

Publication Publication Date Title
Yang et al. Performance of three air distribution systems in VOC removal from an area source
Pei et al. Effect of sensor position on the performance of CO2-based demand controlled ventilation
Rim et al. Ventilation effectiveness as an indicator of occupant exposure to particles from indoor sources
Chung et al. Effect of ventilation pattern on room air and contaminant distribution
Novoselac et al. Impact of placement of portable air cleaning devices in multizone residential environments
Amai et al. Experimental study on air change effectiveness in mixing ventilation
Lee et al. Effect of internal partitioning on indoor air quality of rooms with mixing ventilation—basic study
Kabanshi et al. Experimental evaluation of an intermittent air supply system–Part 1: Thermal comfort and ventilation efficiency measurements
He et al. Removal of contaminants released from room surfaces by displacement and mixing ventilation: modeling and validation
Cao et al. Modelling and experimental study of performance of the protected occupied zone ventilation
Qin et al. Effects of ceiling exhaust location on thermal comfort and age of air in room under impinging jet supply scheme
Sekhar et al. Impact of airflow profile on indoor air quality—a tropical study
Han et al. Evaluation of the ventilation mode in an ISO class 6 electronic cleanroom by the AHP-entropy weight method
Yang et al. A coupled airflow and source/sink model for simulating indoor VOC exposures
Jurelionis et al. Combined air heating and ventilation increases risk of personal exposure to airborne pollutants released at the floor level
Murga et al. Decreasing inhaled contaminant dose of a factory worker through a hybrid Emergency Ventilation System: Performance evaluation in worst-case scenario
Mikeska et al. Full scale measurements and CFD simulations of diffuse ceiling inlet for ventilation and cooling of densely occupied rooms
Qin et al. Transmission mitigation of COVID-19: Exhaled contaminants removal and energy saving in densely occupied space by impinging jet ventilation
Jin et al. Experimental study of ventilation performance in laboratories with chemical spills
Raftery et al. Laboratory testing of a displacement ventilation diffuser for underfloor air distribution systems
Kwok et al. Impact of shaft design to thermal comfort and indoor air quality of floors using BIM technology
Qin et al. Mitigation of breathing contaminants: Exhaust location optimization for indoor space with impinging jet ventilation supply
Yang et al. Prediction of short-term and long-term VOC emissions from SBR bitumen-backed carpet under different temperatures/Discussion
Liu et al. Numerical simulation of inter-flat air cross-contamination under the condition of single-sided natural ventilation
Noh et al. Effect of the airflow rate of a ceiling type air-conditioner on ventilation effectiveness in a lecture room