Zhang et al., 2020 - Google Patents
Investigation of a simple coded-aperture based multi-narrow beam x-ray luminescence computed tomography systemZhang et al., 2020
View PDF- Document ID
- 2086273386729438625
- Author
- Zhang Y
- Guo Q
- Zhang L
- Li J
- Gao F
- Jiang J
- Zhou Z
- Publication year
- Publication venue
- Review of Scientific Instruments
External Links
Snippet
The purpose of this paper is to introduce and study a multi-narrow beam X-ray Luminescence Computed Tomography (XLCT) system based on a simple coded aperture. The proposed XLCT system is studied through simulations of x rays and diffuse light …
- 238000002591 computed tomography 0 title abstract description 9
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01N—INVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
- G01N23/00—Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons
- G01N23/02—Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons by transmitting the radiation through the material
- G01N23/04—Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons by transmitting the radiation through the material and forming a picture
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/29—Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
- G01T1/2914—Measurement of spatial distribution of radiation
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01N—INVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
- G01N2223/00—Investigating materials by wave or particle radiation
- G01N2223/40—Imaging
- G01N2223/419—Imaging computed tomograph
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
-
- G—PHYSICS
- G21—NUCLEAR PHYSICS; NUCLEAR ENGINEERING
- G21K—TECHNIQUES FOR HANDLING PARTICLES OR IONISING RADIATION NOT OTHERWISE PROVIDED FOR; IRRADIATION DEVICES; GAMMA RAY OR X-RAY MICROSCOPES
- G21K1/00—Arrangements for handling particles or ionizing radiation, e.g. focusing or moderating
- G21K1/06—Arrangements for handling particles or ionizing radiation, e.g. focusing or moderating using diffraction, refraction or reflection, e.g. monochromators
-
- G—PHYSICS
- G21—NUCLEAR PHYSICS; NUCLEAR ENGINEERING
- G21K—TECHNIQUES FOR HANDLING PARTICLES OR IONISING RADIATION NOT OTHERWISE PROVIDED FOR; IRRADIATION DEVICES; GAMMA RAY OR X-RAY MICROSCOPES
- G21K7/00—Gamma- or X-ray microscopes
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Wang et al. | From synchrotron radiation to lab source: advanced speckle-based X-ray imaging using abrasive paper | |
Schropp et al. | Hard x-ray nanobeam characterization by coherent diffraction microscopy | |
JP6529968B2 (en) | X-ray grating phase contrast imaging apparatus and method | |
Li et al. | Full-field fan-beam x-ray fluorescence computed tomography with a conventional x-ray tube and photon-counting detectors for fast nanoparticle bioimaging | |
Zhang et al. | Method for improving the spatial resolution of narrow x-ray beam-based x-ray luminescence computed tomography imaging | |
Astolfo et al. | Large field of view, fast and low dose multimodal phase-contrast imaging at high x-ray energy | |
Zamir et al. | Recent advances in edge illumination x-ray phase-contrast tomography | |
Zhang et al. | X-ray luminescence computed tomography using a focused x-ray beam | |
Lakshmanan et al. | Design and implementation of coded aperture coherent scatter spectral imaging of cancerous and healthy breast tissue samples | |
Arfelli et al. | A Gaussian extension for diffraction enhanced imaging | |
Arhatari et al. | X-ray phase-contrast computed tomography for soft tissue imaging at the imaging and medical beamline (IMBL) of the Australian synchrotron | |
Wu et al. | Prototype system of noninterferometric phase-contrast computed tomography utilizing medical imaging components | |
Vernekohl et al. | Reduced acquisition time for L‐shell x‐ray fluorescence computed tomography using polycapillary x‐ray optics | |
Wagermaier et al. | Understanding Hierarchy and Functions of Bone Using Scanning X‐ray Scattering Methods | |
Zhang et al. | Investigation of a simple coded-aperture based multi-narrow beam x-ray luminescence computed tomography system | |
CN109709127A (en) | Low scattered x-ray fluorescence CT imaging method | |
Zhang et al. | Full-field fan-beam x-ray fluorescence computed tomography system design with linear-array detectors and pinhole collimation: a rapid Monte Carlo study | |
Schrapp et al. | Data fusion in neutron and X-ray computed tomography | |
Lun et al. | Fast three-dimensional focused x-ray luminescence computed tomography | |
Fu et al. | Analysis and correction of dynamic geometric misalignment for nano-scale computed tomography at BSRF | |
Kern et al. | Design for a coherent-scatter imaging system compatible with screening mammography | |
Lakshmanan et al. | Experimental implementation of coded aperture coherent scatter spectral imaging of cancerous and healthy breast tissue samples | |
Lun et al. | X-ray luminescence imaging for small animals | |
Hagen et al. | Quantitative edge illumination x-ray phase contrast tomography | |
Feng et al. | X-ray fluorescence microtomography based on polycapillary-focused X-rays from laboratory source |