Maltz et al., 2008 - Google Patents

Focused beam‐stop array for the measurement of scatter in megavoltage portal and cone beam CT imaging

Maltz et al., 2008

View PDF
Document ID
191671875810389715
Author
Maltz J
Gangadharan B
Vidal M
Paidi A
Bose S
Faddegon B
Aubin M
Morin O
Pouliot J
Zheng Z
Svatos M
Bani‐Hashemi A
Publication year
Publication venue
Medical physics

External Links

Snippet

We describe a focused beam‐stop array (BSA) for the measurement of object scatter in imaging systems that utilize x‐ray beams in the megavoltage (MV) energy range. The BSA consists of 64 doubly truncated tungsten cone elements of maximum diameter that are …
Continue reading at www.academia.edu (PDF) (other versions)

Classifications

    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/58Testing, adjusting or calibrating devices for radiation diagnosis
    • A61B6/582Calibration
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/02Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
    • A61B6/03Computerised tomographs
    • A61B6/032Transmission computed tomography [CT]
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/103Treatment planning systems
    • A61N5/1031Treatment planning systems using a specific method of dose optimization
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/48Diagnostic techniques
    • A61B6/482Diagnostic techniques involving multiple energy imaging
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06TIMAGE DATA PROCESSING OR GENERATION, IN GENERAL
    • G06T11/002D [Two Dimensional] image generation
    • G06T11/003Reconstruction from projections, e.g. tomography
    • G06T11/005Specific pre-processing for tomographic reconstruction, e.g. calibration, source positioning, rebinning, scatter correction, retrospective gating
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/1048Monitoring, verifying, controlling systems and methods
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/42Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for detecting radiation specially adapted for radiation diagnosis
    • A61B6/4291Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for detecting radiation specially adapted for radiation diagnosis the detector being combined with a grid or grating

Similar Documents

Publication Publication Date Title
Wang et al. Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter–Part II: System modeling, scatter correction, and optimization
Jarry et al. Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations
Niu et al. Shading correction for on‐board cone‐beam CT in radiation therapy using planning MDCT images
Zhu et al. Scatter correction for cone‐beam CT in radiation therapy
Mail et al. The influence of bowtie filtration on cone‐beam CT image quality
Jia et al. A GPU tool for efficient, accurate, and realistic simulation of cone beam CT projections
Tzedakis et al. The effect of overscanning on patient effective dose from multidetector helical computed tomography examinations
Maltz et al. Algorithm for X-ray scatter, beam-hardening, and beam profile correction in diagnostic (kilovoltage) and treatment (megavoltage) cone beam CT
Wendling et al. Accurate two‐dimensional IMRT verification using a back‐projection EPID dosimetry method
Saito Potential of dual‐energy subtraction for converting CT numbers to electron density based on a single linear relationship
Maltz et al. Focused beam‐stop array for the measurement of scatter in megavoltage portal and cone beam CT imaging
Chen et al. Characterization of scatter in cone‐beam CT breast imaging: Comparison of experimental measurements and Monte Carlo simulation
McKenney et al. Experimental validation of a method characterizing bow tie filters in CT scanners using a real‐time dose probe
Wang et al. Scatter correction for cone‐beam computed tomography using moving blocker strips: a preliminary study
Granton et al. A combined dose calculation and verification method for a small animal precision irradiator based on onboard imaging
Yagi et al. Gemstone spectral imaging: determination of CT to ED conversion curves for radiotherapy treatment planning
Ritschl et al. Robust primary modulation‐based scatter estimation for cone‐beam CT
Hupfer et al. Dosimetry concepts for scanner quality assurance and tissue dose assessment in micro‐CT
Lazos et al. Impact of flat panel‐imager veiling glare on scatter‐estimation accuracy and image quality of a commercial on‐board cone‐beam CT imaging system
Alexeev et al. Two‐dimensional antiscatter grid: A novel scatter rejection device for Cone‐beam computed tomography
Li et al. Implementation of dual‐energy technique for virtual monochromatic and linearly mixed CBCTs
Mettivier et al. Cone‐beam breast computed tomography with a displaced flat panel detector array
Sun et al. Correction for patient table‐induced scattered radiation in cone‐beam computed tomography (CBCT)
Myronakis et al. Low‐dose megavoltage cone‐beam computed tomography using a novel multi‐layer imager (MLI)
Petit et al. Calibration of megavoltage cone‐beam CT for radiotherapy dose calculations: correction of cupping artifacts and conversion of CT numbers to electron density