Jonsson et al., 1994 - Google Patents
Optimized reduction of the magnetic field near Swedish 400 KV lines by advanced control of shield wire currents. Test results and economic evaluationJonsson et al., 1994
- Document ID
- 17255261272948670453
- Author
- Jonsson U
- Larsson A
- Sjodin J
- Publication year
- Publication venue
- IEEE Transactions on Power Delivery
External Links
Snippet
The design of existing Swedish 400 kV lines is described, especially as regards parameters influencing the characteristics of the magnetic field. Field reduction possibilities by introducing controlled shield wire currents on the relatively new delta configuration are …
- 230000001603 reducing 0 title abstract description 23
Classifications
-
- H—ELECTRICITY
- H01—BASIC ELECTRIC ELEMENTS
- H01F—MAGNETS; INDUCTANCES; TRANSFORMERS; SELECTION OF MATERIALS FOR THEIR MAGNETIC PROPERTIES
- H01F38/00—Adaptations of transformers or inductances for specific applications or functions
- H01F38/20—Instruments transformers
- H01F38/22—Instruments transformers for single phase ac
- H01F38/28—Current transformers
- H01F38/30—Constructions
-
- H—ELECTRICITY
- H01—BASIC ELECTRIC ELEMENTS
- H01F—MAGNETS; INDUCTANCES; TRANSFORMERS; SELECTION OF MATERIALS FOR THEIR MAGNETIC PROPERTIES
- H01F38/00—Adaptations of transformers or inductances for specific applications or functions
- H01F38/02—Adaptations of transformers or inductances for specific applications or functions for non-linear operation
- H01F38/023—Adaptations of transformers or inductances for specific applications or functions for non-linear operation of inductances
-
- H—ELECTRICITY
- H02—GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
- H02J—CIRCUIT ARRANGEMENTS OR SYSTEMS FOR SUPPLYING OR DISTRIBUTING ELECTRIC POWER; SYSTEMS FOR STORING ELECTRIC ENERGY
- H02J3/00—Circuit arrangements for ac mains or ac distribution networks
- H02J3/18—Arrangements for adjusting, eliminating, or compensating reactive power in networks
- H02J3/1821—Arrangements for adjusting, eliminating, or compensating reactive power in networks using shunt compensators
-
- H—ELECTRICITY
- H01—BASIC ELECTRIC ELEMENTS
- H01F—MAGNETS; INDUCTANCES; TRANSFORMERS; SELECTION OF MATERIALS FOR THEIR MAGNETIC PROPERTIES
- H01F27/00—Details of transformers or inductances, in general
- H01F27/34—Special means for preventing or reducing unwanted electric or magnetic effects, e.g. no-load losses, reactive currents, harmonics, oscillations, leakage fields
-
- H—ELECTRICITY
- H01—BASIC ELECTRIC ELEMENTS
- H01F—MAGNETS; INDUCTANCES; TRANSFORMERS; SELECTION OF MATERIALS FOR THEIR MAGNETIC PROPERTIES
- H01F27/00—Details of transformers or inductances, in general
- H01F27/28—Coils; Windings; Conductive connections
- H01F27/32—Insulating of coils, windings, or parts thereof
- H01F2027/329—Insulation with semiconducting layer, e.g. to reduce corona effect
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Jonsson et al. | Optimized reduction of the magnetic field near Swedish 400 KV lines by advanced control of shield wire currents. Test results and economic evaluation | |
Meliopoulis | Power system grounding and transients: an introduction | |
US7489485B2 (en) | Method and equipment for the protection of power systems against geomagnetically induced currents | |
Lahtinen et al. | GIC occurrences and GIC test for 400 kV system transformer | |
Chen et al. | Analysis of multi-grounded four-wire distribution systems considering the neutral grounding | |
Zheng et al. | Effects of system characteristics on geomagnetically induced currents | |
Yamazaki et al. | Requirements for power line magnetic field mitigation using a passive loop conductor | |
Li et al. | A revised model for calculating HV cable sheath current under short-circuit fault condition and its application for fault location—Part 1: The revised model | |
Liang et al. | A single-phase-to-ground fault detection method based on the ratio fluctuation coefficient of the zero-sequence current and voltage differential in a distribution network | |
Tang et al. | Analysis of electromagnetic interference on DC line from parallel AC line in close proximity | |
Alexander et al. | Estimation of Power losses caused by supraharmonics | |
Sueker | Power electronics design: a practitioner's guide | |
US5360998A (en) | Magnetic field minimization in power transmission | |
Mohan et al. | Harmonics and switching transients in the presence of geomagnetically-induced currents | |
Stipetic et al. | LF signal injection for earth-fault localization in unearthed distribution network | |
Li et al. | Electromagnetic interference caused by a power system network on a neighboring pipeline | |
Ke et al. | Grounding techniques and induced surge voltage on the control signal cables | |
Yuze et al. | Calculation of induced voltage and current on a crossing transmission line under uhv ac transmission lines | |
Holbert et al. | Magnetic fields produced by underground residential distribution system | |
Van Waes et al. | Safety aspects of GSM systems on high-voltage towers: an experimental analysis | |
Davarpanah et al. | Practical solutions for ground grid circulating currents caused by air‐core reactor | |
El-Refaie et al. | Electromagnetic field interference between high voltage transmission lines and nearby metallic gas pipelines | |
Benato et al. | Resonance phenomena on line-to-ground fault current harmonics in MV networks | |
Mackow et al. | Simulation of secondary arc on 400-kV transmission system consisting of overhead line section and power cable section | |
Yang et al. | Analysis of Electromagnetic Field Compatibility (EMC) Compliance of HVDC Converter Station |