[go: up one dir, main page]
More Web Proxy on the site http://driver.im/

Chowdhury et al., 2019 - Google Patents

Optimal design and modeling of server cabinets with in-row coolers and air conditioning units in a modular data center

Chowdhury et al., 2019

Document ID
15326516841143151920
Author
Chowdhury U
Hendrix W
Craft T
James W
Sutaria A
Agonafer D
Publication year
Publication venue
International Electronic Packaging Technical Conference and Exhibition

External Links

Snippet

In a data center, electronic equipment such as server and switches dissipate heat and the corresponding cooling systems contribute to typically 25–35% of total energy consumption. The heat load continues to increase as there is a greater need for miniaturization and …
Continue reading at asmedigitalcollection.asme.org (other versions)

Classifications

    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/20709Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
    • H05K7/20718Forced ventilation of a gaseous coolant
    • H05K7/20745Forced ventilation of a gaseous coolant within rooms for removing heat from cabinets, e.g. by air conditioning device
    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/20536Modifications to facilitate cooling, ventilating, or heating for racks or cabinets of standardized dimensions, e.g. 19-inch electronic racks
    • H05K7/20554Forced ventilation of a gaseous coolant
    • H05K7/20572Forced ventilation of a gaseous coolant within cabinets for removing heat from sub-racks, e.g. plenum
    • H05K7/20581Cabinets including a drawer for fans
    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/20536Modifications to facilitate cooling, ventilating, or heating for racks or cabinets of standardized dimensions, e.g. 19-inch electronic racks
    • H05K7/20554Forced ventilation of a gaseous coolant
    • H05K7/2059Forced ventilation of a gaseous coolant within rooms for removing heat from cabinets, e.g. by air conditioning device
    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/20536Modifications to facilitate cooling, ventilating, or heating for racks or cabinets of standardized dimensions, e.g. 19-inch electronic racks
    • H05K7/20554Forced ventilation of a gaseous coolant
    • H05K7/20563Forced ventilation of a gaseous coolant within sub-racks for removing heat from electronic boards
    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/20009Modifications to facilitate cooling, ventilating, or heating using a gaseous coolant in electronic enclosures
    • H05K7/20136Forced ventilation, e.g. by fans
    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/2089Modifications to facilitate cooling, ventilating, or heating for power electronics, e.g. for inverters for controlling motor
    • H05K7/20909Forced ventilation, e.g. on heat dissipaters coupled to components
    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/20218Modifications to facilitate cooling, ventilating, or heating using a liquid coolant without phase change in electronic enclosures
    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/14Mounting supporting structure in casing or on frame or rack
    • H05K7/1422Printed circuit boards receptacles, e.g. stacked structures, electronic circuit modules or box like frames

Similar Documents

Publication Publication Date Title
JP6258450B2 (en) Cold train encapsulation for server farm cooling system
EP2484187B1 (en) Modular system for data center
JP5301009B2 (en) Data center cooling
EP3146816B1 (en) Modular data center row infrastructure
TWI624752B (en) Data center having a cold row encapsulation structure for cooling servers and method thereof
US9772610B2 (en) Modular data center
JP5209584B2 (en) Modular data center
US20100216388A1 (en) Systems and Methods for Closed Loop Heat Containment with Cold Aisle Isolation for Data Center Cooling
Chowdhury et al. Optimal design and modeling of server cabinets with in-row coolers and air conditioning units in a modular data center
US9158345B1 (en) Managing computer performance
US20100248609A1 (en) Assembly For Providing A Downflow Return Air Supply
Onyiorah et al. Effectiveness of rack-level containment in removing data center hot-spots
Baer Emerging cooling requirements & systems in telecommunications spaces
Huang et al. RACK‐LEVEL COOLING AND SERVER‐LEVEL COOLING
Coles et al. Rack-Level Cooling and Cold Plate Cooling
Chowdhury Cooling Efficiency Improvement of a Data Center Using Optimized Cabinet Design and Hybrid Cooling with High Inlet Conditions of Single-Phase Coolant and Air
Dong et al. Micro-environment strategy for efficient cooling in telecommunication base stations
AU2015203315B2 (en) Modular system for data center
Dong et al. Towards Greener Telecommunication Base Stations Through Micro-Environment Strategy
Roncoli Venegas Data Center Design and Airflow Management (Insight into Increasing Performance and Efficiency)
Mynampati Alternative cooling technologies for telecommunication data centers: Air cooling and rear door heat exchangers