Watson et al., 2004 - Google Patents
Advances in scatter correction for 3D PET/CTWatson et al., 2004
- Document ID
- 13541935990261800923
- Author
- Watson C
- Casey M
- Michel C
- Bendriem B
- Publication year
- Publication venue
- IEEE Symposium Conference Record Nuclear Science 2004.
External Links
Snippet
We report on several significant improvements to the implementation of image-based scatter correction for 3D PET and PET/CT. Among these advances are: a new algorithm to scale the estimated scatter sinogram to the measured data, thereby largely compensating for external …
- 238000004422 calculation algorithm 0 abstract description 11
Classifications
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T11/00—2D [Two Dimensional] image generation
- G06T11/003—Reconstruction from projections, e.g. tomography
- G06T11/005—Specific pre-processing for tomographic reconstruction, e.g. calibration, source positioning, rebinning, scatter correction, retrospective gating
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/032—Transmission computed tomography [CT]
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/10—Image acquisition modality
- G06T2207/10072—Tomographic images
- G06T2207/10104—Positron emission tomography [PET]
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/30—Subject of image; Context of image processing
- G06T2207/30004—Biomedical image processing
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/10—Image acquisition modality
- G06T2207/10072—Tomographic images
- G06T2207/10084—Hybrid tomography; Concurrent acquisition with multiple different tomographic modalities
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/58—Testing, adjusting or calibrating devices for radiation diagnosis
- A61B6/582—Calibration
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2211/00—Image generation
- G06T2211/40—Computed tomography
- G06T2211/424—Iterative
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T5/00—Image enhancement or restoration, e.g. from bit-mapped to bit-mapped creating a similar image
- G06T5/001—Image restoration
- G06T5/002—Denoising; Smoothing
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/48—Diagnostic techniques
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T7/00—Image analysis
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/29—Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
- G01T1/2914—Measurement of spatial distribution of radiation
- G01T1/2985—In depth localisation, e.g. using positron emitters; Tomographic imaging (longitudinal and transverse section imaging; apparatus for radiation diagnosis sequentially in different planes, steroscopic radiation diagnosis)
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Watson et al. | Advances in scatter correction for 3D PET/CT | |
Alessio et al. | Application and evaluation of a measured spatially variant system model for PET image reconstruction | |
Ljungberg et al. | Comparison of four scatter correction methods using Monte Carlo simulated source distributions | |
Conti | Why is TOF PET reconstruction a more robust method in the presence of inconsistent data? | |
Zbijewski et al. | Efficient Monte Carlo based scatter artifact reduction in cone-beam micro-CT | |
US6631284B2 (en) | Combined PET and X-ray CT tomograph | |
El Fakhri et al. | Relative impact of scatter, collimator response, attenuation, and finite spatial resolution corrections in cardiac SPECT | |
Chang et al. | Effects of injected dose, BMI and scanner type on NECR and image noise in PET imaging | |
US20090110256A1 (en) | System and method for image-based attenuation correction of pet/spect images | |
Zoccarato et al. | Comparative analysis of iterative reconstruction algorithms with resolution recovery for cardiac SPECT studies. A multi-center phantom study | |
US9928617B2 (en) | System and method for multi-modality time-of-flight attenuation correction | |
Teimoorisichani et al. | A CT‐less approach to quantitative PET imaging using the LSO intrinsic radiation for long‐axial FOV PET scanners | |
Cade et al. | Use of measured scatter data for the attenuation correction of single photon emission tomography without transmission scanning | |
Daube-Witherspoon et al. | Influence of time-of-flight kernel accuracy in TOF-PET reconstruction | |
Miwa et al. | Evaluation of scatter limitation correction: a new method of correcting photopenic artifacts caused by patient motion during whole-body PET/CT imaging | |
Kinahan et al. | Statistical image reconstruction in PET with compensation for missing data | |
Song et al. | Motion‐compensated image reconstruction vs postreconstruction correction in respiratory‐binned SPECT with standard and reduced‐dose acquisitions | |
Cheng et al. | Investigation of practical initial attenuation image estimates in TOF‐MLAA reconstruction for PET/MR | |
WO2012066443A1 (en) | Fast computation of the sensitivity matrix in iterative algorithms | |
Namías et al. | Patient and scanner-specific variable acquisition times for whole-body PET/CT imaging | |
Gustafsson et al. | Evaluation of attenuation corrections using Monte Carlo simulated lung SPECT | |
Cuddy‐Walsh et al. | Patient‐specific estimation of spatially variant image noise for a pinhole cardiac SPECT camera | |
Dennerlein et al. | Geometric jitter compensation in cone-beam CT through registration of directly and indirectly filtered projections | |
Kalantari et al. | Attenuation correction in 4D‐PET using a single‐phase attenuation map and rigidity‐adaptive deformable registration | |
Tang et al. | Use of x-ray CT-defined regions of interest for the determination of SPECT recovery coefficients |