Nute et al., 2018 - Google Patents

Development of a dual‐energy computed tomography quality control program: characterization of scanner response and definition of relevant parameters for a fast …

Nute et al., 2018

View HTML
Document ID
11675138741871726667
Author
Nute J
Jacobsen M
Stefan W
Wei W
Cody D
Publication year
Publication venue
Medical physics

External Links

Snippet

Purpose A prototype QC phantom system and analysis process were developed to characterize the spectral capabilities of a fast kV‐switching dual‐energy computed tomography (DECT) scanner. This work addresses the current lack of quantitative oversight …
Continue reading at www.ncbi.nlm.nih.gov (HTML) (other versions)

Classifications

    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/02Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
    • A61B6/03Computerised tomographs
    • A61B6/032Transmission computed tomography [CT]
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/58Testing, adjusting or calibrating devices for radiation diagnosis
    • A61B6/582Calibration
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/48Diagnostic techniques
    • A61B6/482Diagnostic techniques involving multiple energy imaging
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06TIMAGE DATA PROCESSING OR GENERATION, IN GENERAL
    • G06T11/002D [Two Dimensional] image generation
    • G06T11/003Reconstruction from projections, e.g. tomography
    • G06T11/005Specific pre-processing for tomographic reconstruction, e.g. calibration, source positioning, rebinning, scatter correction, retrospective gating
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/40Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for generating radiation specially adapted for radiation diagnosis
    • A61B6/4007Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for generating radiation specially adapted for radiation diagnosis characterised by using a plurality of source units
    • A61B6/4014Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for generating radiation specially adapted for radiation diagnosis characterised by using a plurality of source units arranged in multiple source-detector units
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/50Clinical applications
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B5/00Detecting, measuring or recording for diagnostic purposes; Identification of persons
    • A61B5/05Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F19/00Digital computing or data processing equipment or methods, specially adapted for specific applications
    • G06F19/30Medical informatics, i.e. computer-based analysis or dissemination of patient or disease data
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N23/00Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons
    • G01N23/02Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons by transmitting the radiation through the material

Similar Documents

Publication Publication Date Title
Kalender et al. Application‐and patient size‐dependent optimization of x‐ray spectra for CT
Hua et al. Accuracy of electron density, effective atomic number, and iodine concentration determination with a dual‐layer dual‐energy computed tomography system
Nute et al. Development of a dual‐energy computed tomography quality control program: characterization of scanner response and definition of relevant parameters for a fast‐kVp switching dual‐energy computed tomography system
Carney et al. Method for transforming CT images for attenuation correction in PET/CT imaging
Saito Potential of dual‐energy subtraction for converting CT numbers to electron density based on a single linear relationship
Hansen et al. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark
Sahbaee et al. Patient‐based estimation of organ dose for a population of 58 adult patients across 13 protocol categories
Solomon et al. Relating noise to image quality indicators in CT examinations with tube current modulation
Wang et al. Correlation between CT attenuation value and iodine concentration in vitro: Discrepancy between gemstone spectral imaging on single‐source dual‐energy CT and traditional polychromatic X‐ray imaging
Brady et al. How to appropriately calculate effective dose for CT using either size-specific dose estimates or dose-length product
Mei et al. Bone mineral density measurements in vertebral specimens and phantoms using dual-layer spectral computed tomography
Pevsner et al. Effect of motion on tracer activity determination in CT attenuation corrected PET images: a lung phantom study
Qi et al. Extraction of tumor motion trajectories using PICCS‐4DCBCT: a validation study
Robar et al. Novel technology allowing cone beam computed tomography in 6 seconds: a patient study of comparative image quality
Gallivanone et al. A Partial Volume Effect Correction Tailored for 18F‐FDG‐PET Oncological Studies
Moore et al. Developments in and experience of kilovoltage X-ray cone beam image-guided radiotherapy
Siewerdsen et al. Cone‐beam CT dose and imaging performance evaluation with a modular, multipurpose phantom
Shi et al. Library based x‐ray scatter correction for dedicated cone beam breast CT
Ohkubo et al. An effective method to verify line and point spread functions measured in computed tomography
Rodriguez et al. CT reconstruction techniques for improved accuracy of lung CT airway measurement
Taasti et al. Theoretical and experimental analysis of photon counting detector CT for proton stopping power prediction
Zhong et al. Deep learning image reconstruction algorithm reduces image noise while alters radiomics features in dual-energy CT in comparison with conventional iterative reconstruction algorithms: a phantom study
van Straten et al. Automated bone removal in CT angiography: Comparison of methods based on single energy and dual energy scans
Ai et al. HU deviation in lung and bone tissues: characterization and a corrective strategy
Li et al. Accuracy of dual‐energy computed tomography for the quantification of iodine in a soft tissue‐mimicking phantom