Vinke et al., 2009 - Google Patents

Optimization of digital time pickoff methods for LaBr 3-SiPM TOF-PET detectors

Vinke et al., 2009

View PDF
Document ID
10651240758697795277
Author
Vinke R
Seifert S
Schaart D
Schreuder F
De Boer M
Van Dam H
Beekman F
Löhner H
Dendooven P
Publication year
Publication venue
2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)

External Links

Snippet

The relatively new inorganic scintillator LaBr 3: Ce is well suited for time-of-flight positron emission tomography (TOF-PET), since it has short scintillation decay time, high light yield and very good energy resolution. Silicon photomultipliers (SiPMs) show low noise, high gain …
Continue reading at research.rug.nl (PDF) (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/161Application in the field of nuclear medicine, e.g. in vivo counting
    • G01T1/164Scintigraphy
    • G01T1/1641Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
    • G01T1/1647Processing of scintigraphic data
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/20Measuring radiation intensity with scintillation detectors
    • G01T1/2008Measuring radiation intensity with scintillation detectors using a combination of different types of scintillation detectors, e.g. phoswich
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/20Measuring radiation intensity with scintillation detectors
    • G01T1/2018Scintillation-photodiode combination
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/20Measuring radiation intensity with scintillation detectors
    • G01T1/2006Measuring radiation intensity with scintillation detectors using a combination of a scintillator and photodetector which measures the means radiation intensity
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/29Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
    • G01T1/2914Measurement of spatial distribution of radiation
    • G01T1/2985In depth localisation, e.g. using positron emitters; Tomographic imaging (longitudinal and transverse section imaging; apparatus for radiation diagnosis sequentially in different planes, steroscopic radiation diagnosis)
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/24Measuring radiation intensity with semiconductor detectors
    • G01T1/241Electrode arrangements, e.g. continuous or parallel strips or the like
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/17Circuit arrangements not adapted to a particular type of detector
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01JMEASUREMENT OF INTENSITY, VELOCITY, SPECTRAL CONTENT, POLARISATION, PHASE OR PULSE CHARACTERISTICS OF INFRA-RED, VISIBLE OR ULTRA-VIOLET LIGHT; COLORIMETRY; RADIATION PYROMETRY
    • G01J1/00Photometry, e.g. photographic exposure meter

Similar Documents

Publication Publication Date Title
Lecoq et al. SiPM applications in positron emission tomography: toward ultimate PET time-of-flight resolution
Schaart et al. A novel, SiPM-array-based, monolithic scintillator detector for PET
Kuhn et al. Design of a lanthanum bromide detector for time-of-flight PET
US10234572B2 (en) Multiple spatial resolution scintillation detectors
Schaart et al. LaBr3: Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving time
US8791514B2 (en) Providing variable cell density and sizes in a radiation detector
Kang et al. A dual-ended readout detector using a meantime method for SiPM TOF-DOI PET
Song et al. A sub-millimeter resolution PET detector module using a multi-pixel photon counter array
US20180038966A1 (en) Universal readout for silicon photomultiplier based detectors
Moses et al. Factors influencing timing resolution in a commercial LSO PET camera
Spanoudaki et al. Use of single photon counting detector arrays in combined PET/MR: Characterization of LYSO-SiPM detector modules and comparison with a LSO-APD detector
Vinke et al. Optimization of digital time pickoff methods for LaBr 3-SiPM TOF-PET detectors
CN110632641B (en) Positron imaging method and system for double-readout PET detector
Kwon et al. Signal encoding method for a time-of-flight PET detector using a silicon photomultiplier array
Huber et al. Characterization of a 64 channel PET detector using photodiodes for crystal identification
Kim et al. Time-of-flight PET detector based on multi-pixel photon counter and its challenges
Henseler et al. SiPM performance in PET applications: An experimental and theoretical analysis
Yeom et al. Readout electronics and data acquisition of a positron emission tomography time-of-flight detector module with waveform digitizer
Nakamori et al. Development of a gamma-ray imager using a large area monolithic 4× 4 MPPC array for a future PET scanner
Wiener et al. DOI determination by rise time discrimination in single-ended readout for TOF PET imaging
Zatcepin et al. Detectors in positron emission tomography
Binder et al. Performance evaluation of a staggered three-layer DOI PET detector using a 1 mm LYSO pitch with PETsys TOFPET2 ASIC: comparison of HAMAMATSU and KETEK SiPMs
US8384037B2 (en) Use of crystal location in nuclear imaging apparatus to minimize timing degradation in a photodetector array
Canot et al. Fast and efficient detection of 511 keV photons using Cherenkov light in PbF2 crystal, coupled to a MCP-PMT and SAMPIC digitization module
Moses Photodetectors for nuclear medical imaging