Vinke et al., 2009 - Google Patents
Optimization of digital time pickoff methods for LaBr 3-SiPM TOF-PET detectorsVinke et al., 2009
View PDF- Document ID
- 10651240758697795277
- Author
- Vinke R
- Seifert S
- Schaart D
- Schreuder F
- De Boer M
- Van Dam H
- Beekman F
- Löhner H
- Dendooven P
- Publication year
- Publication venue
- 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC)
External Links
Snippet
The relatively new inorganic scintillator LaBr 3: Ce is well suited for time-of-flight positron emission tomography (TOF-PET), since it has short scintillation decay time, high light yield and very good energy resolution. Silicon photomultipliers (SiPMs) show low noise, high gain …
- 238000005457 optimization 0 title abstract description 4
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/161—Application in the field of nuclear medicine, e.g. in vivo counting
- G01T1/164—Scintigraphy
- G01T1/1641—Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
- G01T1/1647—Processing of scintigraphic data
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/20—Measuring radiation intensity with scintillation detectors
- G01T1/2008—Measuring radiation intensity with scintillation detectors using a combination of different types of scintillation detectors, e.g. phoswich
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/20—Measuring radiation intensity with scintillation detectors
- G01T1/2018—Scintillation-photodiode combination
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/20—Measuring radiation intensity with scintillation detectors
- G01T1/2006—Measuring radiation intensity with scintillation detectors using a combination of a scintillator and photodetector which measures the means radiation intensity
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/29—Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
- G01T1/2914—Measurement of spatial distribution of radiation
- G01T1/2985—In depth localisation, e.g. using positron emitters; Tomographic imaging (longitudinal and transverse section imaging; apparatus for radiation diagnosis sequentially in different planes, steroscopic radiation diagnosis)
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/24—Measuring radiation intensity with semiconductor detectors
- G01T1/241—Electrode arrangements, e.g. continuous or parallel strips or the like
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/17—Circuit arrangements not adapted to a particular type of detector
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01J—MEASUREMENT OF INTENSITY, VELOCITY, SPECTRAL CONTENT, POLARISATION, PHASE OR PULSE CHARACTERISTICS OF INFRA-RED, VISIBLE OR ULTRA-VIOLET LIGHT; COLORIMETRY; RADIATION PYROMETRY
- G01J1/00—Photometry, e.g. photographic exposure meter
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Lecoq et al. | SiPM applications in positron emission tomography: toward ultimate PET time-of-flight resolution | |
Schaart et al. | A novel, SiPM-array-based, monolithic scintillator detector for PET | |
Kuhn et al. | Design of a lanthanum bromide detector for time-of-flight PET | |
US10234572B2 (en) | Multiple spatial resolution scintillation detectors | |
Schaart et al. | LaBr3: Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving time | |
US8791514B2 (en) | Providing variable cell density and sizes in a radiation detector | |
Kang et al. | A dual-ended readout detector using a meantime method for SiPM TOF-DOI PET | |
Song et al. | A sub-millimeter resolution PET detector module using a multi-pixel photon counter array | |
US20180038966A1 (en) | Universal readout for silicon photomultiplier based detectors | |
Moses et al. | Factors influencing timing resolution in a commercial LSO PET camera | |
Spanoudaki et al. | Use of single photon counting detector arrays in combined PET/MR: Characterization of LYSO-SiPM detector modules and comparison with a LSO-APD detector | |
Vinke et al. | Optimization of digital time pickoff methods for LaBr 3-SiPM TOF-PET detectors | |
CN110632641B (en) | Positron imaging method and system for double-readout PET detector | |
Kwon et al. | Signal encoding method for a time-of-flight PET detector using a silicon photomultiplier array | |
Huber et al. | Characterization of a 64 channel PET detector using photodiodes for crystal identification | |
Kim et al. | Time-of-flight PET detector based on multi-pixel photon counter and its challenges | |
Henseler et al. | SiPM performance in PET applications: An experimental and theoretical analysis | |
Yeom et al. | Readout electronics and data acquisition of a positron emission tomography time-of-flight detector module with waveform digitizer | |
Nakamori et al. | Development of a gamma-ray imager using a large area monolithic 4× 4 MPPC array for a future PET scanner | |
Wiener et al. | DOI determination by rise time discrimination in single-ended readout for TOF PET imaging | |
Zatcepin et al. | Detectors in positron emission tomography | |
Binder et al. | Performance evaluation of a staggered three-layer DOI PET detector using a 1 mm LYSO pitch with PETsys TOFPET2 ASIC: comparison of HAMAMATSU and KETEK SiPMs | |
US8384037B2 (en) | Use of crystal location in nuclear imaging apparatus to minimize timing degradation in a photodetector array | |
Canot et al. | Fast and efficient detection of 511 keV photons using Cherenkov light in PbF2 crystal, coupled to a MCP-PMT and SAMPIC digitization module | |
Moses | Photodetectors for nuclear medical imaging |