Liebmann et al., 2014 - Google Patents
Patient radiation protection covers for head CT scans–A clinical evaluation of their effectivenessLiebmann et al., 2014
View HTML- Document ID
- 9848597947576506700
- Author
- Liebmann M
- Lüllau T
- Kluge A
- Poppe B
- Von Boetticher H
- Publication year
- Publication venue
- RöFo-Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
External Links
Snippet
Purpose: Although the use of thyroid shields for patients for head CT examinations is reasonable and even required by German regulations, so far available shields are often not used due to difficult applicability. New shields that are easier to use and therefore may gain …
- 238000011156 evaluation 0 title abstract description 4
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/032—Transmission computed tomography [CT]
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/58—Testing, adjusting or calibrating devices for radiation diagnosis
- A61B6/582—Calibration
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/04—Positioning of patients; Tiltable beds or the like
- A61B6/0407—Tables or beds
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/48—Diagnostic techniques
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1048—Monitoring, verifying, controlling systems and methods
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/42—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for detecting radiation specially adapted for radiation diagnosis
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/44—Constructional features of the device for radiation diagnosis
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/20—Measuring radiation intensity with scintillation detectors
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/54—Control of devices for radiation diagnosis
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Mail et al. | The influence of bowtie filtration on cone‐beam CT image quality | |
Ofori et al. | Estimation of adult patient doses for selected X-ray diagnostic examinations | |
Schafer et al. | Antiscatter grids in mobile C‐arm cone‐beam CT: effect on image quality and dose | |
Qiang et al. | Estimation of effective dose of dental X-ray devices | |
Descamps et al. | Measurements of the dose delivered during CT exams using AAPM Task Group Report No. 111 | |
Matsubara et al. | Assessment of an organ‐based tube current modulation in thoracic computed tomography | |
Liebmann et al. | Patient radiation protection covers for head CT scans–A clinical evaluation of their effectiveness | |
Ngaile et al. | Estimation of patient organ doses from CT examinations in Tanzania | |
Mundi et al. | Diagnostic reference level for adult brain computed tomography scans: A case study of a tertiary health care center in Nigeria | |
McMillan et al. | Size‐specific, scanner‐independent organ dose estimates in contiguous axial and helical head CT examinations | |
Bibbo et al. | Diagnostic reference levels of paediatric computed tomography examinations performed at a dedicated Australian paediatric hospital | |
Perisinakis et al. | The effect of head size/shape, miscentering, and bowtie filter on peak patient tissue doses from modern brain perfusion 256‐slice CT: How can we minimize the risk for deterministic effects? | |
Rana et al. | Dosimetry of adult and pediatric patients for common digital radiography examinations | |
Wang et al. | Bismuth Pelvic X‐Ray Shielding Reduces Radiation Dose Exposure in Pediatric Radiography | |
Tamam et al. | Occupational and patients effective radiation doses in dental imaging | |
Kim | The development of bismuth shielding to protect the thyroid gland in radiations environment | |
Huda et al. | In‐patient to isocenter KERMA ratios in CT | |
Boissonnat et al. | Performance of automatic exposure control on dose and image quality: comparison between slot‐scanning and flat‐panel digital radiography systems | |
Hauri et al. | No increase in effective dose from half compared to full rotation pelvis cone beam CT | |
Trevisan et al. | Measurements of computed tomography dose index for clinical scans | |
Corredoira et al. | Biplane interventional pediatric system with cone‐beam CT: dose and image quality characterization for the default protocols | |
Jung et al. | Effect of jaw size in megavoltage CT on image quality and dose | |
Oliveira et al. | Kerma profile measurements in CT chest scans–a comparison of methodologies | |
Huda | A radiation exposure index for CT | |
Correia et al. | Characterization of a lead breast shielding for dose reduction in computed tomography |