Olson et al., 1979 - Google Patents
Performance characteristics of a translate-rotate head scanner with xenon detectorsOlson et al., 1979
- Document ID
- 9429336548447015953
- Author
- Olson A
- High M
- Publication year
- Publication venue
- Optical Engineering
External Links
Snippet
The performance and dosimetric characteristics of the first US-installed hybrid head scanner developed commercially by CGR Medical Corporation have been evaluated. Using a translate-rotate motion with a xenon gas detector array, the scanner produces excellent low …
- 229910052724 xenon 0 title abstract description 14
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/032—Transmission computed tomography [CT]
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/58—Testing, adjusting or calibrating devices for radiation diagnosis
- A61B6/582—Calibration
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/20—Measuring radiation intensity with scintillation detectors
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/48—Diagnostic techniques
- A61B6/482—Diagnostic techniques involving multiple energy imaging
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01N—INVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
- G01N23/00—Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons
- G01N23/02—Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons by transmitting the radiation through the material
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01N—INVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
- G01N2223/00—Investigating materials by wave or particle radiation
- G01N2223/60—Specific applications or type of materials
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Shikhaliev et al. | Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application | |
Åslund et al. | Scatter rejection in multislit digital mammography | |
EP1737346B1 (en) | Dynamic dose control for computed tomography | |
US20120230576A1 (en) | Extended low contrast detectability for radiographic imaging systems | |
US4225789A (en) | Device for computer tomography | |
JP6031618B2 (en) | X-ray imaging apparatus, X-ray imaging method, and monitoring method of X-ray imaging apparatus | |
JP2020511641A (en) | X-ray detection system based on photon counting | |
US9903964B2 (en) | Method to calibrate a photon detector, absorption filter assembly and imaging apparatus | |
Cho et al. | Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging | |
EP0338233B1 (en) | Apparatus for measuring the peak voltage applied to a radiation source | |
Fuchs et al. | Direct comparison of a xenon and a solid-state CT detector system: measurements under working conditions | |
Workman et al. | Signal, noise and SNR transfer properties of computed radiography | |
McCullough | Specifying and evaluating the performance of computed tomography (CT) scanners | |
Khodajou-Chokami et al. | A novel method for measuring the mtf of ct scanners: A phantom study | |
Hsieh | Investigation of the slice sensitivity profile for step‐and‐shoot mode multi‐slice computed tomography | |
Perisinakis et al. | The effect of x‐ray beam quality and geometry on radiation utilization efficiency in multidetector CT imaging | |
Kengyelics et al. | Physical imaging performance of a compact computed radiography acquisition device | |
Cai et al. | Scatter correction using beam stop array algorithm for cone-beam CT breast imaging | |
Olson et al. | Performance characteristics of a translate-rotate head scanner with xenon detectors | |
Grätz et al. | Time-gated x-ray tomography | |
Sabol et al. | Mammographic scanning equalization radiography | |
Shaw et al. | Effectiveness of antiscatter grids in digital radiography: a phantom study | |
Willson | Principles of CT | |
Cacak et al. | Performance evaluation of a fourth-generation computed tomography (CT) scanner | |
Wagner et al. | Computed Radiography-A Low Dose X-Ray Imaging System |