Olson et al., 1979 - Google Patents

Performance characteristics of a translate-rotate head scanner with xenon detectors

Olson et al., 1979

Document ID
9429336548447015953
Author
Olson A
High M
Publication year
Publication venue
Optical Engineering

External Links

Snippet

The performance and dosimetric characteristics of the first US-installed hybrid head scanner developed commercially by CGR Medical Corporation have been evaluated. Using a translate-rotate motion with a xenon gas detector array, the scanner produces excellent low …
Continue reading at www.spiedigitallibrary.org (other versions)

Classifications

    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/02Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
    • A61B6/03Computerised tomographs
    • A61B6/032Transmission computed tomography [CT]
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/58Testing, adjusting or calibrating devices for radiation diagnosis
    • A61B6/582Calibration
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/20Measuring radiation intensity with scintillation detectors
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/48Diagnostic techniques
    • A61B6/482Diagnostic techniques involving multiple energy imaging
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N23/00Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons
    • G01N23/02Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons by transmitting the radiation through the material
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N2223/00Investigating materials by wave or particle radiation
    • G01N2223/60Specific applications or type of materials

Similar Documents

Publication Publication Date Title
Shikhaliev et al. Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application
Åslund et al. Scatter rejection in multislit digital mammography
EP1737346B1 (en) Dynamic dose control for computed tomography
US20120230576A1 (en) Extended low contrast detectability for radiographic imaging systems
US4225789A (en) Device for computer tomography
JP6031618B2 (en) X-ray imaging apparatus, X-ray imaging method, and monitoring method of X-ray imaging apparatus
JP2020511641A (en) X-ray detection system based on photon counting
US9903964B2 (en) Method to calibrate a photon detector, absorption filter assembly and imaging apparatus
Cho et al. Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging
EP0338233B1 (en) Apparatus for measuring the peak voltage applied to a radiation source
Fuchs et al. Direct comparison of a xenon and a solid-state CT detector system: measurements under working conditions
Workman et al. Signal, noise and SNR transfer properties of computed radiography
McCullough Specifying and evaluating the performance of computed tomography (CT) scanners
Khodajou-Chokami et al. A novel method for measuring the mtf of ct scanners: A phantom study
Hsieh Investigation of the slice sensitivity profile for step‐and‐shoot mode multi‐slice computed tomography
Perisinakis et al. The effect of x‐ray beam quality and geometry on radiation utilization efficiency in multidetector CT imaging
Kengyelics et al. Physical imaging performance of a compact computed radiography acquisition device
Cai et al. Scatter correction using beam stop array algorithm for cone-beam CT breast imaging
Olson et al. Performance characteristics of a translate-rotate head scanner with xenon detectors
Grätz et al. Time-gated x-ray tomography
Sabol et al. Mammographic scanning equalization radiography
Shaw et al. Effectiveness of antiscatter grids in digital radiography: a phantom study
Willson Principles of CT
Cacak et al. Performance evaluation of a fourth-generation computed tomography (CT) scanner
Wagner et al. Computed Radiography-A Low Dose X-Ray Imaging System