Hamill et al., 2024 - Google Patents
Energy‐based scatter estimation in clinical PETHamill et al., 2024
View HTML- Document ID
- 9069933926116792274
- Author
- Hamill J
- Cabello J
- Surti S
- Karp J
- Publication year
- Publication venue
- Medical Physics
External Links
Snippet
Background Scatter correction (SC) is essential in PET for accurate quantitative imaging. The state‐of‐the‐art SC method is single‐scatter simulation (SSS). Although this method is usually robust and accurate, it can fail in some situations, for example when there is motion …
- 238000000034 method 0 abstract description 47
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/161—Application in the field of nuclear medicine, e.g. in vivo counting
- G01T1/164—Scintigraphy
- G01T1/1641—Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
- G01T1/1647—Processing of scintigraphic data
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/161—Application in the field of nuclear medicine, e.g. in vivo counting
- G01T1/164—Scintigraphy
- G01T1/1641—Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
- G01T1/1648—Ancillary equipment for scintillation cameras, e.g. reference markers, devices for removing motion artifacts, calibration devices
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T11/00—2D [Two Dimensional] image generation
- G06T11/003—Reconstruction from projections, e.g. tomography
- G06T11/005—Specific pre-processing for tomographic reconstruction, e.g. calibration, source positioning, rebinning, scatter correction, retrospective gating
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/29—Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
- G01T1/2914—Measurement of spatial distribution of radiation
- G01T1/2985—In depth localisation, e.g. using positron emitters; Tomographic imaging (longitudinal and transverse section imaging; apparatus for radiation diagnosis sequentially in different planes, steroscopic radiation diagnosis)
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T11/00—2D [Two Dimensional] image generation
- G06T11/003—Reconstruction from projections, e.g. tomography
- G06T11/006—Inverse problem, transformation from projection-space into object-space, e.g. transform methods, back-projection, algebraic methods
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2211/00—Image generation
- G06T2211/40—Computed tomography
- G06T2211/424—Iterative
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/10—Image acquisition modality
- G06T2207/10072—Tomographic images
- G06T2207/10104—Positron emission tomography [PET]
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/10—Image acquisition modality
- G06T2207/10072—Tomographic images
- G06T2207/10084—Hybrid tomography; Concurrent acquisition with multiple different tomographic modalities
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/30—Subject of image; Context of image processing
- G06T2207/30004—Biomedical image processing
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/032—Transmission computed tomography [CT]
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/037—Emission tomography
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Tong et al. | Image reconstruction for PET/CT scanners: past achievements and future challenges | |
Alessio et al. | Application and evaluation of a measured spatially variant system model for PET image reconstruction | |
Berker et al. | Attenuation correction in emission tomography using the emission data—a review | |
Zaidi et al. | Scatter modelling and compensation in emission tomography | |
Rahmim et al. | Resolution modeling in PET imaging: theory, practice, benefits, and pitfalls | |
Iriarte et al. | System models for PET statistical iterative reconstruction: A review | |
Beekman et al. | Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation | |
Liu et al. | Comparison of 3-D reconstruction with 3D-OSEM and with FORE+ OSEM for PET | |
Bowsher et al. | Bayesian reconstruction and use of anatomical a priori information for emission tomography | |
Carlier et al. | 90Y‐PET imaging: exploring limitations and accuracy under conditions of low counts and high random fraction | |
Llacer et al. | Statistical analysis of maximum likelihood estimator images of human brain FDG PET studies | |
Chun et al. | Correction for collimator-detector response in SPECT using point spread function template | |
Gaitanis et al. | PET image reconstruction: A stopping rule for the MLEM algorithm based on properties of the updating coefficients | |
Cloquet et al. | Non-Gaussian space-variant resolution modelling for list-mode reconstruction | |
US11361478B2 (en) | Partial volume correction in multi-modality emission tomography | |
Aguiar et al. | Geometrical and Monte Carlo projectors in 3D PET reconstruction | |
Khateri et al. | Implementation of cylindrical PET scanners with block detector geometry in STIR | |
US10102650B2 (en) | Model-based scatter correction for non-parallel-hole collimators | |
D′ Ambrosio et al. | Attenuation correction for small animal PET images: a comparison of two methods | |
Mahani et al. | Spinning slithole collimation for high-sensitivity small animal SPECT: Design and assessment using GATE simulation | |
Hamill et al. | Energy‐based scatter estimation in clinical PET | |
Peterson et al. | Monte Carlo-based quantitative pinhole SPECT reconstruction using a ray-tracing back-projector | |
Perez et al. | Towards quantification of functional breast images using dedicated SPECT with non-traditional acquisition trajectories | |
Khalil | Emission tomography and image reconstruction | |
Hamill | Phantom evaluation of energy-based scatter estimation in an SiPM PET scanner |