Sanchez et al., 2006 - Google Patents
Effects of artifact rejection and Bayesian weighting on the auditory brainstem response during quiet and active behavioral conditionsSanchez et al., 2006
View PDF- Document ID
- 8883511608047484091
- Author
- Sanchez J
- Gans D
- Publication year
- Publication venue
- American journal of audiology
External Links
Snippet
Purpose To evaluate the effects of 2 noise reduction techniques on the auditory brainstem response (ABR). Method ABRs of 20 normal hearing adults were recorded during quiet and active behavioral conditions using 2 stimulus intensity levels. Wave V amplitudes and …
- 230000000694 effects 0 title abstract description 20
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/72—Signal processing specially adapted for physiological signals or for diagnostic purposes
- A61B5/7235—Details of waveform analysis
- A61B5/7253—Details of waveform analysis characterised by using transforms
- A61B5/7257—Details of waveform analysis characterised by using transforms using Fourier transforms
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/04—Detecting, measuring or recording bioelectric signals of the body of parts thereof
- A61B5/0402—Electrocardiography, i.e. ECG
- A61B5/0452—Detecting specific parameters of the electrocardiograph cycle
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/04—Detecting, measuring or recording bioelectric signals of the body of parts thereof
- A61B5/0476—Electroencephalography
- A61B5/0484—Electroencephalography using evoked response
- A61B5/04845—Electroencephalography using evoked response acoustically or auditory
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/04—Detecting, measuring or recording bioelectric signals of the body of parts thereof
- A61B5/0476—Electroencephalography
- A61B5/048—Detecting the frequency distribution of signals
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/12—Audiometering Evaluation or the auditory system, not limited to hearing capacity
- A61B5/121—Audiometering Evaluation or the auditory system, not limited to hearing capacity evaluating hearing capacity
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/72—Signal processing specially adapted for physiological signals or for diagnostic purposes
- A61B5/7225—Details of analog processing, e.g. isolation amplifier, gain or sensitivity adjustment, filtering, baseline or drift compensation
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/68—Arrangements of detecting, measuring or recording means, e.g. sensors, in relation to patient
- A61B5/6801—Arrangements of detecting, measuring or recording means, e.g. sensors, in relation to patient specially adapted to be attached to or worn on the body surface
- A61B5/6813—Specially adapted to be attached to a specific body part
- A61B5/6814—Head
- A61B5/6815—Ear
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/04—Detecting, measuring or recording bioelectric signals of the body of parts thereof
- A61B5/0488—Electromyography
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/72—Signal processing specially adapted for physiological signals or for diagnostic purposes
- A61B5/7203—Signal processing specially adapted for physiological signals or for diagnostic purposes for noise prevention, reduction or removal
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/48—Other medical applications
- A61B5/4806—Sleep evaluation
- A61B5/4818—Sleep apnoea
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/05—Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves
- A61B5/053—Measuring electrical impedance or conductance of a portion of the body
- A61B5/0531—Measuring skin impedance
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/08—Detecting, measuring or recording devices for evaluating the respiratory organs
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B7/00—Instruments for auscultation
- A61B7/02—Stethoscopes
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N1/00—Electrotherapy; Circuits therefor
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Koka et al. | Electrocochleography in cochlear implant recipients with residual hearing: comparison with audiometric thresholds | |
Small et al. | Multiple auditory steady-state response thresholds to bone-conduction stimuli in young infants with normal hearing | |
Sininger et al. | Evaluation of speed and accuracy of next-generation auditory steady state response and auditory brainstem response audiometry in children with normal hearing and hearing loss | |
Tichko et al. | Frequency-dependent fine structure in the frequency-following response: The byproduct of multiple generators | |
Korczak et al. | Effects of sensorineural hearing loss and personal hearing aids on cortical event-related potential and behavioral measures of speech-sound processing | |
Martin et al. | The effects of decreased audibility produced by high-pass noise masking on N1 and the mismatch negativity to speech sounds/ba/and/da | |
Aoyagi et al. | Reliability of 80-Hz amplitude-modulation-following response detected by phase coherence | |
Small et al. | Artifactual responses when recording auditory steady-state responses | |
US6602202B2 (en) | System and methods for objective evaluation of hearing using auditory steady-state responses | |
Prieve et al. | Identification of conductive hearing loss in young infants using tympanometry and wideband reflectance | |
Hatton et al. | The efficiency of the single-versus multiple-stimulus auditory steady state responses in infants | |
Choi et al. | Envelope following responses elicited by English sentences | |
Easwar et al. | Test-retest variability in the characteristics of envelope following responses evoked by speech stimuli | |
BinKhamis et al. | Speech auditory brainstem responses: Effects of background, stimulus duration, consonant–vowel, and number of epochs | |
Ménard et al. | Relationship between loudness growth function and auditory steady-state response in normal-hearing subjects | |
Koka et al. | An objective estimation of air-bone-gap in cochlear implant recipients with residual hearing using electrocochleography | |
Ozdek et al. | Comparison of pure tone audiometry and auditory steady-state responses in subjects with normal hearing and hearing loss | |
Mertes et al. | Concurrent measures of contralateral suppression of transient-evoked otoacoustic emissions and of auditory steady-state responses | |
Dzulkarnain et al. | Effects of different electrode configurations on the narrow band level-specific CE-Chirp and tone-burst auditory brainstem response at multiple intensity levels and frequencies in subjects with normal hearing | |
Kapul et al. | Pure-tone audiometer | |
Polonenko et al. | Optimizing parameters for using the parallel auditory brainstem response to quickly estimate hearing thresholds | |
Kirby et al. | Effects of nonlinear frequency compression on ACC amplitude and listener performance | |
Sanchez et al. | Effects of artifact rejection and Bayesian weighting on the auditory brainstem response during quiet and active behavioral conditions | |
Mishra et al. | Stability of the medial olivocochlear reflex as measured by distortion product otoacoustic emissions | |
Beck et al. | Auditory steady-state response (ASSR): a beginner's guide |