Tsui et al., 1990 - Google Patents

The geometric transfer function for cone and fan beam collimators

Tsui et al., 1990

Document ID
8872694939580269385
Author
Tsui B
Gullberg G
Publication year
Publication venue
Physics in Medicine & Biology

External Links

Snippet

Geometric response functions are derived for both cone and fan beam collimators for the scintillation camera. The formulation is based on an effective response function which is determined by the geometric response of a single hole. The technique provides an accurate …
Continue reading at iopscience.iop.org (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/161Application in the field of nuclear medicine, e.g. in vivo counting
    • G01T1/164Scintigraphy
    • G01T1/1641Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
    • G01T1/1648Ancillary equipment for scintillation cameras, e.g. reference markers, devices for removing motion artifacts, calibration devices
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/29Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation

Similar Documents

Publication Publication Date Title
Tsui et al. The geometric transfer function for cone and fan beam collimators
Gullberg et al. Estimation of geometrical parameters and collimator evaluation for cone beam tomography
EP1760457B1 (en) Method and a system for calibrating a measuring apparatus
DE19882431B4 (en) Dual-mode camera system
DE69129008T2 (en) X-RAY RAY THERAPY SIMULATOR
Hesterman et al. The multi‐module, multi‐resolution system: A novel small‐animal SPECT system
EP0438555A1 (en) Transmission/emission registered image (teri) computed tomography scanners
DE3521293C2 (en) Method for correcting the spatial measured values of a rotatable Ï camera
Dey Improvement of performance of cardiac SPECT camera using curved detectors with pinholes
Heller et al. SPECT instrumentation: performance, lesion detection, and recent innovations
US7375338B1 (en) Swappable collimators method and system
Massari et al. Super Spatial Resolution (SSR) method for small animal SPECT imaging: A Monte Carlo study
Beekman et al. Improvement of image resolution and quantitative accuracy in clinical single photon emission computed tomography
DE102016004624A1 (en) The gamma eye: A device for imaging high-energy objects
Jaszczak et al. Imaging characteristics of a high resolution cone beam collimator
Zeng et al. Image reconstruction algorithm for a rotating slat collimator
Bae et al. Simulation study of a novel target oriented SPECT design using a variable pinhole collimator
Tenney et al. Uranium pinhole collimators for 511-keV photon SPECT imaging of small volumes
Rowe A system for three-dimensional SPECT without motion
Wang Development and applications of high-sensitivity and high-resolution fully three-dimensional SPECT imaging techniques using two different collimator designs
Saha et al. Single photon emission computed tomography
Zeng et al. Image reconstruction algorithm for a spinning strip CZT SPECT camera with a parallel slat collimator and small pixels: CZT SPECT camera using small pixels
Tsui et al. Micro-SPECT
Chung et al. Investigation of scatter radiation of non-circular X-ray scan trajectories
Keyes Current Status of Single Photon Emission Computerised Tomography