Tsui et al., 1990 - Google Patents
The geometric transfer function for cone and fan beam collimatorsTsui et al., 1990
- Document ID
- 8872694939580269385
- Author
- Tsui B
- Gullberg G
- Publication year
- Publication venue
- Physics in Medicine & Biology
External Links
Snippet
Geometric response functions are derived for both cone and fan beam collimators for the scintillation camera. The formulation is based on an effective response function which is determined by the geometric response of a single hole. The technique provides an accurate …
- 238000002603 single-photon emission computed tomography 0 abstract description 24
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/161—Application in the field of nuclear medicine, e.g. in vivo counting
- G01T1/164—Scintigraphy
- G01T1/1641—Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
- G01T1/1648—Ancillary equipment for scintillation cameras, e.g. reference markers, devices for removing motion artifacts, calibration devices
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/29—Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Tsui et al. | The geometric transfer function for cone and fan beam collimators | |
Gullberg et al. | Estimation of geometrical parameters and collimator evaluation for cone beam tomography | |
EP1760457B1 (en) | Method and a system for calibrating a measuring apparatus | |
DE19882431B4 (en) | Dual-mode camera system | |
DE69129008T2 (en) | X-RAY RAY THERAPY SIMULATOR | |
Hesterman et al. | The multi‐module, multi‐resolution system: A novel small‐animal SPECT system | |
EP0438555A1 (en) | Transmission/emission registered image (teri) computed tomography scanners | |
DE3521293C2 (en) | Method for correcting the spatial measured values of a rotatable Ï camera | |
Dey | Improvement of performance of cardiac SPECT camera using curved detectors with pinholes | |
Heller et al. | SPECT instrumentation: performance, lesion detection, and recent innovations | |
US7375338B1 (en) | Swappable collimators method and system | |
Massari et al. | Super Spatial Resolution (SSR) method for small animal SPECT imaging: A Monte Carlo study | |
Beekman et al. | Improvement of image resolution and quantitative accuracy in clinical single photon emission computed tomography | |
DE102016004624A1 (en) | The gamma eye: A device for imaging high-energy objects | |
Jaszczak et al. | Imaging characteristics of a high resolution cone beam collimator | |
Zeng et al. | Image reconstruction algorithm for a rotating slat collimator | |
Bae et al. | Simulation study of a novel target oriented SPECT design using a variable pinhole collimator | |
Tenney et al. | Uranium pinhole collimators for 511-keV photon SPECT imaging of small volumes | |
Rowe | A system for three-dimensional SPECT without motion | |
Wang | Development and applications of high-sensitivity and high-resolution fully three-dimensional SPECT imaging techniques using two different collimator designs | |
Saha et al. | Single photon emission computed tomography | |
Zeng et al. | Image reconstruction algorithm for a spinning strip CZT SPECT camera with a parallel slat collimator and small pixels: CZT SPECT camera using small pixels | |
Tsui et al. | Micro-SPECT | |
Chung et al. | Investigation of scatter radiation of non-circular X-ray scan trajectories | |
Keyes | Current Status of Single Photon Emission Computerised Tomography |