DePuey, 1994 - Google Patents
How to detect and avoid myocardial perfusion SPECT artifactsDePuey, 1994
View PDF- Document ID
- 8790368153240206208
- Author
- DePuey E
- Publication year
- Publication venue
- Journal of Nuclear Medicine
External Links
Snippet
Incorrect axis selection may:(a) foreshorten normal yen tricularwalls, creating apparentbasal defects;(b) displace the apical †œdimple, ― creating an apparentperi-apicalper fusion defect;(c) or misplace true perfusion defects (Fig. 2), causing the interpreting physician to …
- 230000002107 myocardial 0 title description 9
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/032—Transmission computed tomography [CT]
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/037—Emission tomography
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/50—Clinical applications
- A61B6/507—Clinical applications involving determination of haemodynamic parameters, e.g. perfusion CT
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/50—Clinical applications
- A61B6/504—Clinical applications involving diagnosis of blood vessels, e.g. by angiography
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/30—Subject of image; Context of image processing
- G06T2207/30004—Biomedical image processing
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/48—Diagnostic techniques
- A61B6/481—Diagnostic techniques involving the use of contrast agents
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/02—Detecting, measuring or recording pulse, heart rate, blood pressure or blood flow; Combined pulse/heart-rate/blood pressure determination; Evaluating a cardiovascular condition not otherwise provided for, e.g. using combinations of techniques provided for in this group with electrocardiography or electroauscultation; Heart catheters for measuring blood pressure
- A61B5/026—Measuring blood flow
- A61B5/0275—Measuring blood flow using tracers, e.g. dye dilution
- A61B5/02755—Radioactive tracers
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/161—Application in the field of nuclear medicine, e.g. in vivo counting
- G01T1/164—Scintigraphy
- G01T1/1641—Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
- G01T1/1648—Ancillary equipment for scintillation cameras, e.g. reference markers, devices for removing motion artifacts, calibration devices
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/52—Devices using data or image processing specially adapted for radiation diagnosis
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/72—Signal processing specially adapted for physiological signals or for diagnostic purposes
- A61B5/7271—Specific aspects of physiological measurement analysis
- A61B5/7285—Specific aspects of physiological measurement analysis for synchronising or triggering a physiological measurement or image acquisition with a physiological event or waveform, e.g. an ECG signal
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/10—Image acquisition modality
- G06T2207/10072—Tomographic images
- G06T2207/10084—Hybrid tomography; Concurrent acquisition with multiple different tomographic modalities
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T7/00—Image analysis
- G06T7/0002—Inspection of images, e.g. flaw detection
- G06T7/0012—Biomedical image inspection
Similar Documents
Publication | Publication Date | Title |
---|---|---|
DePuey | How to detect and avoid myocardial perfusion SPECT artifacts | |
Maddahi et al. | Improved noninvasive assessment of coronary artery disease by quantitative analysis of regional stress myocardial distribution and washout of thallium-201. | |
Hansen et al. | Myocardial perfusion and function: single photon emission computed tomography | |
DePuey et al. | Updated imaging guidelines for nuclear cardiology procedures | |
Gibson et al. | Low event rate for stress-only perfusion imaging in patients evaluated for chest pain | |
Van Train et al. | Quantitative Analysis of Stress Thallium-201 Myocardial Scintrigrams: A Multicenter Trial | |
Case et al. | Taking the perfect nuclear image: quality control, acquisition, and processing techniques for cardiac SPECT, PET, and hybrid imaging | |
Vallejo et al. | Assessment of left ventricular ejection fraction with quantitative gated SPECT: accuracy and correlation with first-pass radionuclide angiography | |
Reiber et al. | Clinical validation of fully automated computation of ejection fraction from gated equilibrium blood-pool scintigrams | |
Nichols et al. | Reliability of enhanced gated SPECT in assessing wall motion of severely hypoperfused myocardium: echocardiographic validation | |
Underwood et al. | Gated blood-pool emission tomography: a new technique for the investigation of cardiac structure and function | |
Kaul et al. | Quantitative aspects of myocardial perfusion imaging | |
US7409240B1 (en) | System and method for imaging myocardial infarction | |
Kennedy et al. | Motion detection and amelioration in a dedicated cardiac solid-state CZT SPECT device | |
Ohtake et al. | Evaluation of regurgitant fraction of the left ventricle by gated cardiac blood-pool scanning using SPECT | |
Brady et al. | Segmental wall-motion analysis in the right anterior oblique projection: Comparison of exercise equilibrium radionuclide ventriculography and exercise contrast ventriculography | |
Perkins et al. | Reliability of the hepatic perfusion index for the detection of liver metastases | |
Adam et al. | Radionuclide ventriculography (equilibrium gated blood pool scanning)—its present clinical position and recent development | |
Mititelu et al. | Common artifacts in myocardial perfusion imaging | |
Davis et al. | Assessment of left ventricular ejection fraction from technetium-99m-methoxy isobutyl isonitrile multiple-gated radionuclide angiocardiography | |
Grüning et al. | X-ray-based attenuation correction of myocardial perfusion scans: practical feasibility and diagnostic impact | |
Le Jeune et al. | Emission computed tomography vs perfusion scanning in lung disease | |
Vos | Nuclear cardiology | |
Piez Jr et al. | Single photon emission computed tomography | |
Cross et al. | Assessment of left ventricular regional wall motion with blood pool tomography: comparison of: 11: CO PET with: 99: Tc: m: SPECT |