Vaz-Garcia et al., 2018 - Google Patents
Mechanical properties of anatomic finishing files: XP-Endo Finisher and XP-CleanVaz-Garcia et al., 2018
View HTML- Document ID
- 7152357816201110046
- Author
- Vaz-Garcia E
- Vieira V
- Petitet N
- Moreira E
- Lopes H
- Elias C
- Silva E
- Antunes H
- Publication year
- Publication venue
- Brazilian dental journal
External Links
Snippet
The aim of the present study was to evaluate the cyclic fatigue of two anatomic finishing files: XP-Endo Finisher and XP-Clean. Roughness pattern and the micro-hardness of the files were also assessed. Instruments were subjected to cyclic fatigue resistance measuring the …
- 238000004140 cleaning 0 title abstract description 42
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C13/00—Dental prostheses; Making same
- A61C13/0003—Making bridge-work, inlays, implants or the like
- A61C13/0004—Computer-assisted sizing or machining of dental prostheses
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B17/00—Surgical instruments, devices or methods, e.g. tourniquets
- A61B2017/00831—Material properties
- A61B2017/00867—Material properties shape memory effect
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C19/00—Dental auxiliary appliances
- A61C19/04—Measuring instruments specially adapted for dentistry
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C5/00—Filling or capping teeth
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C3/00—Dental tools or instruments
- A61C3/08—Tooth pluggers or hammers
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C2201/00—Material properties
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/0059—Detecting, measuring or recording for diagnostic purposes; Identification of persons using light, e.g. diagnosis by transillumination, diascopy, fluorescence
- A61B5/0082—Detecting, measuring or recording for diagnostic purposes; Identification of persons using light, e.g. diagnosis by transillumination, diascopy, fluorescence adapted for particular medical purposes
- A61B5/0088—Detecting, measuring or recording for diagnostic purposes; Identification of persons using light, e.g. diagnosis by transillumination, diascopy, fluorescence adapted for particular medical purposes for oral or dental tissue
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C1/00—Dental machines for boring or cutting; General features of dental machines or apparatus, e.g. hand-piece design
- A61C1/08—Machine parts specially adapted for dentistry
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/45—For evaluating or diagnosing the musculoskeletal system or teeth
- A61B5/4538—Evaluating a particular part of the muscoloskeletal system or a particular medical condition
- A61B5/4542—Evaluating the mouth, e.g. the jaw
- A61B5/4547—Evaluating teeth
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C7/00—Orthodontics, i.e. obtaining or maintaining the desired position of teeth, e.g. by straightening, evening, regulating, separating, or by correcting malocclusions
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/0059—Detecting, measuring or recording for diagnostic purposes; Identification of persons using light, e.g. diagnosis by transillumination, diascopy, fluorescence
- A61B5/0062—Arrangements for scanning
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61K—PREPARATIONS FOR MEDICAL, DENTAL, OR TOILET PURPOSES
- A61K6/00—Preparations for dentistry
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Vaz-Garcia et al. | Mechanical properties of anatomic finishing files: XP-Endo Finisher and XP-Clean | |
De-Deus et al. | Blue thermomechanical treatment optimizes fatigue resistance and flexibility of the Reciproc files | |
Kabil et al. | Micro–computed evaluation of canal transportation and centering ability of 5 rotary and reciprocating systems with different metallurgical properties and surface treatments in curved root canals | |
Schäfer et al. | Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments. Part 1. Shaping ability in simulated curved canals | |
Stringheta et al. | Micro‐computed tomographic evaluation of the shaping ability of four instrumentation systems in curved root canals | |
Nabavizadeh et al. | A comparison of apical transportation in severely curved canals induced by reciproc and BioRaCe systems | |
Gündoğar et al. | Comparison of the cyclic fatigue resistance of VDW. ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium rotary files at body temperature | |
Marchesan et al. | Impacts of contracted endodontic cavities on primary root canal curvature parameters in mandibular molars | |
Uslu et al. | Comparison of alterations in the surface topographies of HyFlex CM and HyFlex EDM nickel-titanium files after root canal preparation: a three-dimensional optical profilometry study | |
Pessoa et al. | Cyclic fatigue resistance of rotary NiTi instruments after simulated clinical use in curved root canals | |
Hanan et al. | Surface characteristics of reciprocating instruments before and after use-A SEM analysis | |
Antony et al. | Comparative evaluation of canal transportation, centering ability, and dentin removal between ProTaper Gold, one curve, and profit S3: an: in vitro: study | |
Yılmaz et al. | Cyclic fatigue life of Tango-Endo, WaveOne GOLD, and reciproc NiTi instruments | |
Al-Gharrawi et al. | A comparative study to evaluate canal transportation and centering ratio at different levels of simulated curved canals prepared by iRaCe, ProTaper NEXT and ProTaper universal files | |
Schäfer et al. | A critical analysis of research methods and experimental models to study the physical properties of NiTi instruments and their fracture characteristics | |
Bueno et al. | Fracture incidence of WaveOne Gold files: a prospective clinical study | |
Shaheen et al. | Shaping ability and buckling resistance of TruNatomy, WaveOne gold, and XP-Endo shaper single-file systems | |
Moreira et al. | Effects of clinical use of NiTi reciprocating instruments on cyclic and torsional resistance, and on roughness | |
Topçuoğlu et al. | Effect of glide path and apical preparation size on the incidence of apical crack during the canal preparation using Reciproc, WaveOne, and ProTaper Next systems in curved root canals: A stereomicroscope study | |
Ubaed et al. | Cyclic fatigue resistance of nickel–titanium rotary instruments after simulated clinical use | |
Kadhim et al. | Comparison of root canal transportation and centering after instrumentation through conservative and traditional access cavities using different file systems: An: In vitro: Study | |
Uslu et al. | Effect of glide path preparation with PathFile and ProGlider on the cyclic fatigue resistance of WaveOne nickel-titanium files | |
Das et al. | Comparison and evaluation of surface deformation of Hyflex controlled memory and Hyflex electric discharge machining nickel titanium rotary files and cyclic fatigue resistance after instrumentation and heat sterilization–An in vitro study | |
Majumdar et al. | Cone-beam computed tomography assessment of root canal transportation and evaluation of canal centering using Protaper Gold, XP Endoshaper, and Edgefile X7 | |
Srikumar et al. | An in vitro comparative evaluation of cyclic fatigue resistance of two rotary and two reciprocating file systems |