Unprotected floor assemblies and tenability conditions in a test house under two basement fire scenarios

Su et al., 2011

Document ID
6842334899274686426
Author
Su J
Benichou N
Bwalya A
Lougheed G
Taber B
Leroux P
Publication year
Publication venue
Fire technology

External Links

Snippet

A full-scale experimental program was undertaken to study the impact of two basement fire scenarios on the structural integrity of unprotected floor assemblies above a basement and the tenability conditions in a test facility representing a typical two-storey detached single …
Continue reading at link.springer.com (other versions)

Classifications

    • EFIXED CONSTRUCTIONS
    • E04BUILDING
    • E04BGENERAL BUILDING CONSTRUCTIONS; WALLS, e.g. PARTITIONS; ROOFS; FLOORS; CEILINGS; INSULATION OR OTHER PROTECTION OF BUILDINGS
    • E04B1/00Constructions in general; Structures which are not restricted either to walls, e.g. partitions, or floors or ceilings or roofs
    • E04B1/62Insulation or other protection; Elements or use of specified material therefor
    • E04B1/92Protection against other undesired influences or dangers
    • E04B1/94Protection against other undesired influences or dangers against fire
    • EFIXED CONSTRUCTIONS
    • E06DOORS, WINDOWS, SHUTTERS, OR ROLLER BLINDS IN GENERAL; LADDERS
    • E06BFIXED OR MOVABLE CLOSURES FOR OPENINGS IN BUILDINGS, VEHICLES, FENCES OR LIKE ENCLOSURES IN GENERAL, e.g. DOORS, WINDOWS, BLINDS, GATES
    • E06B5/00Doors, windows, or like closures for special purposes; Border constructions therefor
    • E06B5/10Doors, windows, or like closures for special purposes; Border constructions therefor for protection against air-raid or other war-like action; for other protective purposes
    • E06B5/16Fireproof doors or similar closures; Adaptations of fixed constructions therefor
    • EFIXED CONSTRUCTIONS
    • E04BUILDING
    • E04BGENERAL BUILDING CONSTRUCTIONS; WALLS, e.g. PARTITIONS; ROOFS; FLOORS; CEILINGS; INSULATION OR OTHER PROTECTION OF BUILDINGS
    • E04B1/00Constructions in general; Structures which are not restricted either to walls, e.g. partitions, or floors or ceilings or roofs
    • E04B1/18Structures comprising elongated load-supporting parts, e.g. columns, girders, skeletons
    • E04B1/24Structures comprising elongated load-supporting parts, e.g. columns, girders, skeletons the supporting parts consisting of metal

Similar Documents

Publication Publication Date Title
Kodur et al. Fire hazard in buildings: review, assessment and strategies for improving fire safety
Kerber Analysis of changing residential fire dynamics and its implications on firefighter operational timeframes
Fleischmann Is prescription the future of performance-based design
Babrauskas FIRE ENDURANCE IN BUILDINGS.
Nyman Equivalent fire resistance ratings of construction elements exposed to realistic fires
Kerber et al. Effect of firefighting intervention on occupant tenability during a residential fire
Hostikka et al. Experimental investigation of human tenability and sprinkler protection in hospital room fires
Purser Assessment of pre-warning, pre-travel and travel behavior interactions with smoke and toxic gases during fire incidents
Su et al. Unprotected floor assemblies and tenability conditions in a test house under two basement fire scenarios
Barowy et al. Simulation of the Dynamics of a Wind-driven Fire in a Ranch-style House, Texas
Hasburgh et al. Full-scale fire tests of a two-story cross-laminated timber structure
Su et al. Fire Performance of Houses. Phase I. Study of Unprotected Floor Assemblies in Basement Fire Scenarios. Summary Report
Su et al. Tenability analysis for fire experiments conducted in a full-scale test
Bwalya et al. A Literature Review of the Fire Performance of Floor Assemblies Commonly Used in Houses
Eduful Correlation of fire load survey methodologies towards design fires for office buildings
Whitehead Comparative analysis of fire test standards applicable to building materials
Su et al. Fire Performance of Houses Phase I Study of Unprotected Floor Assemblies in Basement Fire Scenarios
Ko Inmate cell fire tenability analysis
Opert Assessment of natural vertical ventilation for smoke and hot gas layer control in a residential scale structure
Hare Preparing the foundation for risk-informed fire safety design
Bénichou et al. Fire Performance of Houses Phase I Study of Unprotected Floor Assemblies in Basement Fire Scenarios
Williams et al. Effectiveness of sprinkler in residential premises
Li Modeling of Barrier Failure and Fire Spread in CUrisk
Chaurasia et al. Analyzing Compliance of Façade Passive Fire Resistance as Per ASTM E2307
Björkman et al. Risk assessment of a timber frame building by using CRISP simulation