Pelizzari et al., 1991 - Google Patents
Interactive 3D patient—image registrationPelizzari et al., 1991
- Document ID
- 4974289448855658488
- Author
- Pelizzari C
- Tan K
- Levin D
- Chen G
- Balter J
- Publication year
- Publication venue
- Information Processing in Medical Imaging: 12th International Conference, IPMI'91 Wye, UK, July 7–12, 1991 Proceedings 12
External Links
Snippet
A method has been developed which allows accurate registration of 3D image data sets of the head, such as CT or MRI, with with the anatomy of the actual patient. Once registration is accomplished, the patient and image spaces may be interactively explored, and any point or …
- 230000002452 interceptive 0 title 1
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1048—Monitoring, verifying, controlling systems and methods
- A61N5/1064—Monitoring, verifying, controlling systems and methods for adjusting radiation treatment in response to monitoring
- A61N5/1065—Beam adjustment
- A61N5/1067—Beam adjustment in real time, i.e. during treatment
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1048—Monitoring, verifying, controlling systems and methods
- A61N5/1049—Monitoring, verifying, controlling systems and methods for verifying the position of the patient with respect to the radiation beam
- A61N2005/1061—Monitoring, verifying, controlling systems and methods for verifying the position of the patient with respect to the radiation beam using an x-ray imaging system having a separate imaging source
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1048—Monitoring, verifying, controlling systems and methods
- A61N5/1049—Monitoring, verifying, controlling systems and methods for verifying the position of the patient with respect to the radiation beam
- A61N2005/1058—Monitoring, verifying, controlling systems and methods for verifying the position of the patient with respect to the radiation beam using ultrasound imaging
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1077—Beam delivery systems
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/103—Treatment planning systems
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N2005/1092—Details
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/04—Positioning of patients; Tiltable beds or the like
- A61B6/0407—Tables or beds
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/05—Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves
- A61B5/055—Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves involving electronic or nuclear magnetic resonance, e.g. magnetic resonance imaging
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B17/00—Surgical instruments, devices or methods, e.g. tourniquets
- A61B17/34—Trocars; Puncturing needles
- A61B17/3403—Needle locating or guiding means
- A61B2017/3405—Needle locating or guiding means using mechanical guide means
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Pelizzari et al. | Interactive 3D patient—image registration | |
Adler Jr et al. | Image-guided robotic radiosurgery | |
Aubry et al. | Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers | |
Boda-Heggemann et al. | Repositioning accuracy of two different mask systems—3D revisited: comparison using true 3D/3D matching with cone-beam CT | |
Ho et al. | A study of the accuracy of cyberknife spinal radiosurgery using skeletal structure tracking | |
Gevaert et al. | Setup accuracy of the Novalis ExacTrac 6DOF system for frameless radiosurgery | |
Hawkins et al. | Assessment of residual error in liver position using kV cone-beam computed tomography for liver cancer high-precision radiation therapy | |
Chang et al. | An analysis of the accuracy of the CyberKnife: a robotic frameless stereotactic radiosurgical system | |
Meeks et al. | Optically guided patient positioning techniques | |
US7634304B2 (en) | Method and apparatus for lesion localization, definition and verification | |
EP2175931B1 (en) | Systems for compensating for changes in anatomy of radiotherapy patients | |
Masi et al. | Cone beam CT image guidance for intracranial stereotactic treatments: comparison with a frame guided set-up | |
Chang et al. | 6D image guidance for spinal non-invasive stereotactic body radiation therapy: Comparison between ExacTrac X-ray 6D with kilo-voltage cone-beam CT | |
Chang et al. | Accuracy and feasibility of cone‐beam computed tomography for stereotactic radiosurgery setup | |
US20080021300A1 (en) | Four-dimensional target modeling and radiation treatment | |
US20050080332A1 (en) | Near simultaneous computed tomography image-guided stereotactic radiotherapy | |
Solberg et al. | Quality assurance of immobilization and target localization systems for frameless stereotactic cranial and extracranial hypofractionated radiotherapy | |
Huntzinger et al. | Dynamic targeting image-guided radiotherapy | |
WO1998002091A1 (en) | High-speed inter-modality image registration via iterative feature matching | |
Salter et al. | The TALON removable head frame system for stereotactic radiosurgery/radiotherapy: measurement of the repositioning accuracy | |
Wagner et al. | Optical tracking technology in stereotactic radiation therapy | |
Galvin et al. | Quality assurance procedures for stereotactic body radiation therapy | |
Ali et al. | Evaluation of the setup accuracy of a stereotactic radiotherapy head immobilization mask system using kV on‐board imaging | |
Shirato et al. | Three-dimensional conformal setup (3D-CSU) of patients using the coordinate system provided by three internal fiducial markers and two orthogonal diagnostic X-ray systems in the treatment room | |
Peng et al. | Quality assessment of frameless fractionated stereotactic radiotherapy using cone beam computed tomography |