Air-Conditioning Design for Data Centers Accommodating Current Loads and Planning for the Future.Kurkjian et al., 2005
- Document ID
- 407858605838335845
- Author
- Kurkjian C
- Glass J
- Publication year
- Publication venue
- ASHRAE transactions
External Links
Snippet
Today's modern enterprise data center must be capable of efficiently operating at current average power densities of 30 to 50 W/ft² (∼ 320 to 540 W/m²) and, based upon industry trends, support growth in the foreseeable future toward 150 W/ft² (∼ 1,610 W/m²) and also …
- 238000004378 air conditioning 0 title description 22
Classifications
-
- H—ELECTRICITY
- H05—ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
- H05K—PRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
- H05K7/00—Constructional details common to different types of electric apparatus
- H05K7/20—Modifications to facilitate cooling, ventilating, or heating
- H05K7/20709—Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
- H05K7/20718—Forced ventilation of a gaseous coolant
- H05K7/20745—Forced ventilation of a gaseous coolant within rooms for removing heat from cabinets, e.g. by air conditioning device
-
- F—MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
- F24—HEATING; RANGES; VENTILATING
- F24F—AIR-CONDITIONING, AIR-HUMIDIFICATION, VENTILATION, USE OF AIR CURRENTS FOR SCREENING
- F24F11/00—Control or safety systems or apparatus
- F24F11/0009—Electrical control or safety systems or apparatus
-
- F—MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
- F24—HEATING; RANGES; VENTILATING
- F24F—AIR-CONDITIONING, AIR-HUMIDIFICATION, VENTILATION, USE OF AIR CURRENTS FOR SCREENING
- F24F3/00—Air-conditioning systems in which conditioned primary air is supplied from one or more central stations to distributing units in the rooms or spaces where it may receive secondary treatment; Apparatus specially designed for such systems
-
- H—ELECTRICITY
- H05—ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
- H05K—PRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
- H05K7/00—Constructional details common to different types of electric apparatus
- H05K7/20—Modifications to facilitate cooling, ventilating, or heating
- H05K7/20536—Modifications to facilitate cooling, ventilating, or heating for racks or cabinets of standardized dimensions, e.g. 19-inch electronic racks
- H05K7/20554—Forced ventilation of a gaseous coolant
- H05K7/2059—Forced ventilation of a gaseous coolant within rooms for removing heat from cabinets, e.g. by air conditioning device
-
- F—MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
- F24—HEATING; RANGES; VENTILATING
- F24F—AIR-CONDITIONING, AIR-HUMIDIFICATION, VENTILATION, USE OF AIR CURRENTS FOR SCREENING
- F24F11/00—Control or safety systems or apparatus
- F24F11/0001—Control or safety systems or apparatus for ventilation
Similar Documents
Publication | Publication Date | Title |
---|---|---|
US7534167B2 (en) | Data center cooling | |
US8984906B2 (en) | Cool design data center | |
US20210092866A1 (en) | Fluid-cooled data centres without air coinditioning, and methods for operating same | |
JP2024527284A (en) | System and method for cooling in an electrical distribution center - Patents.com | |
Kurkjian et al. | Air-Conditioning Design for Data Centers Accommodating Current Loads and Planning for the Future. | |
Bhatia | HVAC Cooling systems for data centers | |
Mathew | Self-benchmarking guide for data centers: Metrics, benchmarks, actions | |
RU126357U1 (en) | DATA PROCESSING CENTER | |
VanGeet et al. | FEMP best practices guide for energy-efficient data center design | |
Kurkjian et al. | Meeting the needs of 24/7 data centers. | |
Musilli et al. | Facilities Design for High‑density Data Centers | |
KR102690214B1 (en) | Rack-based Cooling System for Stable IT Environment of High-density and Hyper-scale Data Centers | |
Sullivan | The Impact of Moore's Law on the Total Cost of Computing and How Inefficiencies in the Data Center Increase These Costs. | |
Rumsey et al. | Chilled Beams | |
Roncoli Venegas | Data Center Design and Airflow Management (Insight into Increasing Performance and Efficiency) | |
NREL | Best practices guide for energy-efficient data center design | |
Moody | Hot Aisle Versus Cold Aisle Containment | |
Fjerdingen et al. | Ventilation and Cooling Requirements for ICT rooms | |
Allen | The development of high reliability modular cooling system in British Telecom | |
Krapivnitckaia | Thermal climate in a data center | |
Xu et al. | Data center energy benchmarking: Part 4-case study on a computer-testing center (no. 21) | |
West | The pros and cons of HVAC cold-air distribution | |
Hahn et al. | Fast-track HVAC conversion | |
Salim et al. | Energy and Cost Analysis of Rittal Corporation Liquid Cooled Package | |
Jennings et al. | AD-A208 810 |