Conclusions
The results of these tests confirm that a prosthesis is easier to control with sensory feedback and that the proposed technique is acceptable to patients as well as to professionals working in this field. Work in this Institute is now directed toward development of the feedback system to a form suitable for inclusion in a prosthesis. This requires miniaturisation, minimisation of power drain, and, hopefully, provision for use of common electrodes for stimulation and control.
Similar content being viewed by others
References
Von Bekesy G. (1957) Sensations on the skin similar to directional hearing, beats and harmonics of the ear.J. Acoustical Soc. Am. 29, 489–501.
Gibson, R. H. (1963) Requirements for the use of electrical stimulationn of the skin,in Clark, L. L.(Ed.): Proceedings of the International Congress on Technology & Blindness, American Foundation for the Blind, New York,2, 183–207.
Gibson, R. H. (1965) Perception of apparent movement from cutaneous electrical stimulation. Research Bull., American Foundation for the Blind, (9), 13–21.
Kato, I. et al. (1969) Human cognitional ability for electrical stimulation signals. Proceedings of the 3rd International Symposium on External Control of Human Extremities, Belgrade, 69–84.
Mann, R. W. andReimers, S. D. (1970) Kinesthetic Sensing for the e.m.g. controlled ‘Boston Arm’.IEEE Trans. MMS-11, 110–115.