Node bindings for the rcswitch RaspberryPi port.
It should be compatible with all versions of Node.js starting from 0.8.
- Like the C++ version of rcswitch, WiringPi must be installed in order to compile.
- Both the data and the power Pins of the 315/433Mhz emitter must be connected to the RPi. Note the number of the WiringPi data Pin. (see http://wiringpi.com/pins/)
- The node command must be run with root access
var rcswitch = require('rcswitch'); // Might throw an error if wiring pi init failed, or exit process if no root (must work on that)
rcswitch.enableTransmit(0); // Use data Pin 0
rcswitch.switchOn("10110", 1); // Switch on the first unit of 10110 (code 1x23x) group
rcswitch.switchOff("11000", 2); // Switch off the second unit of 11000 (code 12xxx) group
Enable reception on the given pin (make it an INPUT). Must be called before any other functions.
pin
- (Number) data Pin to use following the WiringPi schema
Return true if pin
is an integer, false otherwise.
Enable transmission on the given pin (make it an OUTPUT). Must be called before any other functions.
pin
- (Number) data Pin to use following the WiringPi schema
Return true if pin
is an integer, false otherwise.
Disable transmission (set the pin to -1 which disable any following function call).
Return true.
Switch a remote switch on (Type A with 10 pole DIP switches).
group
- (String) code of the switch group (refers to DIP switches 1, 2, 3, 4 and 5 where "1" = on and "0" = off - e.g. if all DIP switches are on it's "11111")switch
- (Number) switch number (can be 1 (if DIP switch A is on), 2 (if DIP switch B is on) and so on until 4)
Return true.
Switch a remote switch off (Type A with 10 pole DIP switches).
group
- (String) code of the switch group (refers to DIP switches 1, 2, 3, 4 and 5 where "1" = on and "0" = off - e.g. if all DIP switches are on it's "11111")switch
- (Number) switch number (can be 1 (if DIP switch A is on), 2 (if DIP switch B is on) and so on until 4)
Return true.
Switch a remote switch on (Type B with two rotary/sliding switches).
group
- (Number) group (can be 1, 2, 3, 4)switch
- (Number) switch (can be 1, 2, 3, 4)
Return true.
Switch a remote switch off (Type B with two rotary/sliding switches).
group
- (Number) group (can be 1, 2, 3, 4)switch
- (Number) switch (can be 1, 2, 3, 4)
Return true.
Switch a remote switch on (Type C Intertechno).
family
- (String) familycode (can be a, b, c, d, e, f)group
- (Number) group (can be 1, 2, 3, 4)switch
- (Number) switch (can be 1, 2, 3, 4)
Return true.
Switch a remote switch off (Type C Intertechno).
family
- (String) familycode (can be a, b, c, d, e, f)group
- (Number) group (can be 1, 2, 3, 4)switch
- (Number) switch (can be 1, 2, 3, 4)
Return true.
Block the execution until a code is received.
Return the received code.
Send raw code.
code
- (Number) codelength
- (Number) length
Return true if code and length are integers, false otherwise.
Send tri-state code.
code
- (String) tri-state code
Return true.
This function is useful for eg. micro-electric AS 73 which is also sold as REV Telecontrol in Germany (Version with house code with 6 DIP switches).
This socket has 10 DIP-Switches.
The house code uses the first 6 switches, the receiver code is set by the next 4 switches. For the house code, the switch position OFF is represented by F and switch position ON by 0.
Receiver codes:
Channel Switches 7-10
-
0FFF
Channel A -
F0FF
Channel B -
FFF0
Channel C -
FF0F
Channel D -
FF
orF0
Button on -
0F
Button off
The input string for the function is [homecode][channel][on/off value]
e.g. F000000FFFFF for homecode 100000, Channel A and button on.