Multi-sample Unit Preprocessing Platform and Its Control System Design

Published: 06 June 2020 Publication History

Abstract

Many complex samples must be preprocessed to analyze and detect. And sample preprocessed accounts for more than 60% of the entire sample analysis process. In order to improve efficiency and accuracy, an automated multi-sample preprocessing platform was designed and its automation control system was discussed.
The functions of the platform mainly include: transferring 10 kinds of solvents, processing 96 samples, ultrasonic treatment, automatic cleaning. The control system of the platform is mainly composed of computer, PLC, syringe pump, distribution valve, sensor, stepping motor, ultrasonic pool, and the three-dimensional motion system. The platform adopts distributed control by LabVIEW and PLC, with friendly human-computer interaction interface and complete function.
The platform selects six syringe pumps equipped with a dispensing valve to achieve the fluid transfer accuracy and efficiency requirements of the platform. The six syringe pumps are independent of each other, and the syringe range is 50μL~50ml.Its working mode divided into normal mode and micro-step mode, which can achieve high throughput and ensure its volume accuracy.
Install some proximity switches on the 3D motion system to achieve zero and limit point positioning for each axis. The PLC compares the current position with the received position command to obtain the difference in orientation. Finally, the PLC sends the required pulses to the stepper motor driver, and the proximity switch can verify the sample position.

References

[1]
Dongsong Cai, Zengyong Dong. Application of Stepper Motor Based on PLC Control on Three-axis Engraving Machine[J]. Harbin Bearing, 2017(3):30--37.
[2]
H Hong. Selection of Operational Parameters of Stepper Motor Based on PLC [J]. Marine Electric & Electronic Engineering, 2016.
[3]
Jing Yang, Chao Yuan. Design and Implementation of Automated Test Software Based on LabVIEW[J]. China Modern Educational Equipment, 2016(7):9--12.
[4]
Juan Wan, Li Zhang, Bingyang Zhang. Design of automatic enzyme-linked immunosorbent pretreatment instrument based on TMCM-6110 and LabVIEW[J]. Manufacturing Automation, 2016(10):1--6.
[5]
Kailun Huang. Design and implementation of high precision automated solution preparation system [D]. Northeast Normal University, 2017.
[6]
Miaojun Shou, Peng Zhao, Jiankun Hu. Development and Prospect of Common Sample Pretreatment Equipment [J]. Analytical Instruments, 2017(5):1--10.
[7]
Y Zhao, LI Ke. Effects of Ultrasonic Treatment on Emulsification Stability of Sodium Caseinate-Soybean Oil Pre-emulsion [J]. Food Science, 2017.
[8]
Yaohua He, Yabin Ku. Realization of Serial Communication between LabVIEW and PLC in Parking Brake Automatic Adjustment System[J]. Automation & Instrumentation, 2018, v.33; No.242(5):89--92.
[9]
Yizheng Li. Design and implementation of micro-injection pump control system [D]. Hunan Normal University, 2011.
[10]
Zhimin Zhang, Dunmin Lu. Design of Motion Control System Based on LabVIEW and PLC Motor[J]. Measurement and Control Technology, 2016, 35(1): 56--60.

Index Terms

  1. Multi-sample Unit Preprocessing Platform and Its Control System Design

    Recommendations

    Comments

    Please enable JavaScript to view thecomments powered by Disqus.

    Information & Contributors

    Information

    Published In

    cover image ACM Other conferences
    ISCSIC 2019: Proceedings of the 2019 3rd International Symposium on Computer Science and Intelligent Control
    September 2019
    397 pages
    ISBN:9781450376617
    DOI:10.1145/3386164
    Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

    Publisher

    Association for Computing Machinery

    New York, NY, United States

    Publication History

    Published: 06 June 2020

    Permissions

    Request permissions for this article.

    Check for updates

    Author Tags

    1. Distributed control system
    2. Multi-sample unit
    3. Sample preparation

    Qualifiers

    • Research-article
    • Research
    • Refereed limited

    Conference

    ISCSIC 2019

    Acceptance Rates

    ISCSIC 2019 Paper Acceptance Rate 77 of 152 submissions, 51%;
    Overall Acceptance Rate 192 of 401 submissions, 48%

    Contributors

    Other Metrics

    Bibliometrics & Citations

    Bibliometrics

    Article Metrics

    • 0
      Total Citations
    • 25
      Total Downloads
    • Downloads (Last 12 months)3
    • Downloads (Last 6 weeks)1
    Reflects downloads up to 21 Dec 2024

    Other Metrics

    Citations

    View Options

    Login options

    View options

    PDF

    View or Download as a PDF file.

    PDF

    eReader

    View online with eReader.

    eReader

    Media

    Figures

    Other

    Tables

    Share

    Share

    Share this Publication link

    Share on social media