[go: up one dir, main page]
More Web Proxy on the site http://driver.im/ skip to main content
10.5555/1983862.1983890guideproceedingsArticle/Chapter ViewAbstractPublication PagesConference Proceedingsacm-pubtype
Article

Establishing calibration models and error envelopes of a 3D whole body scanning system

Published: 16 April 2006 Publication History

Abstract

The accuracy is important for a 3D whole body scanning system. In order to analyze the measurement error, a set of dimension-certified measurement equipment whose true dimensions were certified was introduced. The calibration models of height, breadth and depth measurement between measured values and true dimensions were established respectively and relevant error envelopes were derived. A verification experiment was conducted to determine the validity of these models. The accuracy of this scanning system can be improved by using the calibration models to obtain more accurate 3D human models.

References

[1]
J. A. Roebuck, Anthropometric methods: Designing to Fit the Human Body, CA: Human Factors and Ergonomics Society, Santa Monica, 1995, 25-46, 53-61.
[2]
P. Meunier, S. Yin, Performance a 2D image-based anthropometric measurement and clothing sizing system, Applied Ergonomics, Vol. 31, 2000, 445-451.
[3]
Y. H. Wu, J. Y. Lin, Y. C. Lin, Evaluating the Use of the 3-D Whole Body Scanner to Collect Anthropometric Data for the Development of Automated Tailoring System, Journal of Industrial Engineering Design Vol. 4, 2002, 4-6.
[4]
L. Dekker, Custom-made clothing, Proceedings of 3D anthropometric technology and application, China Textile Institute, 2000, 6-8.
[5]
S. Paquette, D. Brantley, B. D. Corner, P. Li, T. Oliver, Automated Extraction of Anthropometric Data from 3D Images, Proceedings of the IEA 2000/ HFES 2000 Congress, 2000, 727-730.
[6]
M. A. Brunsman, H. M., Daanen, K. M. Robinette, Optimal postures and positioning for human body scanning, Proceedings of International Conference on 3D Digital Imaging and Modeling, 1997, 226-273.
[7]
J. J. Aguilar, F. Torres, M. A. Lope, Stereo vision for 3D measurement: accuracy analysis, calibration and industrial applications, Measurement, Vol. 18, 1996, 193-200.
[8]
H. A. Daanen, S. E. Taylor, M. A. Brunsman, J. H. Nuure, Absolute accuracy of the Cyberware WB4 whole-body scanner, Proceedings of the SPIE, 3023, 1997, 6-12.

Recommendations

Comments

Please enable JavaScript to view thecomments powered by Disqus.

Information & Contributors

Information

Published In

cover image Guide Proceedings
IMCAS'06: Proceedings of the 5th WSEAS international conference on Instrumentation, measurement, circuits and systems
April 2006
355 pages
ISBN:9608457432
  • Editors:
  • Jianwei Zhang,
  • W. L. Wang,
  • S. Y. Chen

Sponsors

  • WSEAST: WSEAS Transactions
  • WSEAS: WSEAS

Publisher

World Scientific and Engineering Academy and Society (WSEAS)

Stevens Point, Wisconsin, United States

Publication History

Published: 16 April 2006

Author Tags

  1. 3D whole body scanner
  2. anthropometry
  3. calibration model
  4. error envelope
  5. measurement error

Qualifiers

  • Article

Contributors

Other Metrics

Bibliometrics & Citations

Bibliometrics

Article Metrics

  • 0
    Total Citations
  • 0
    Total Downloads
  • Downloads (Last 12 months)0
  • Downloads (Last 6 weeks)0
Reflects downloads up to 15 Jan 2025

Other Metrics

Citations

View Options

View options

Media

Figures

Other

Tables

Share

Share

Share this Publication link

Share on social media