Title:Evaluation of an Open-Source Pipeline to Create Patient-Specific Left Atrial Models: A Reproducibility Study
View PDFAbstract:We present an open-source software pipeline to create patient-specific left atrial (LA) models with fibre orientations and a fibrosis map, suitable for electrophysiology simulations. The semi-automatic pipeline takes as input a contrast enhanced magnetic resonance angiogram, and a late gadolinium enhanced (LGE) contrast magnetic resonance (CMR). Five operators were allocated 20 cases each from a set of 50 CMR datasets to create a total of 100 models to evaluate inter/intra-operator variability. Each output model consisted of (1) a labelled surface mesh open at the pulmonary veins (PV) and mitral valve (MV), (2) fibre orientations mapped from a diffusion tensor MRI human atlas, (3) fibrosis map from the LGE-CMR scan, and (4) simulation of local activation time (LAT) and phase singularity (PS) mapping. We evaluated reproducibility in our pipeline by comparing agreement in shape of the output meshes, fibrosis distribution in the LA body, and fibre orientations; simulations outputs were evaluated comparing total activation times of LAT maps, mean conduction velocity (CV), and structural similarity index measure (SSIM) of PS maps. Our workflow allows a single model to be created in 16.72 +/- 12.25 minutes. Results in this abstract are reported as inter/intra. Shape only differed noticeably with users' selection of the MV and the length of the PV from the ostia to the distal end; fibrosis agreement (0.91/0.99 ICC) and fibre orientation agreement (60.63/71.77 %) were high. LAT maps showed good agreement, the median of the absolute difference of the total activation times was 2.02ms/1.37ms. The average of the mean CV difference was -4.04mm/s / 2.1mm/s. PS maps showed a moderately good agreement with SSIM of 0.648/0.608. Although we found notable differences in the models due to user input, our tests show that operator variability was comparable to that of image resolution or fibre estimation.
Submission history
From: José Alonso Solís Lemus [view email][v1] Tue, 17 Jan 2023 16:40:34 UTC (13,216 KB)
[v2] Tue, 9 May 2023 15:51:04 UTC (13,958 KB)
Current browse context:
physics.med-ph
References & Citations
Bibliographic and Citation Tools
Bibliographic Explorer (What is the Explorer?)
Connected Papers (What is Connected Papers?)
Litmaps (What is Litmaps?)
scite Smart Citations (What are Smart Citations?)
Code, Data and Media Associated with this Article
alphaXiv (What is alphaXiv?)
CatalyzeX Code Finder for Papers (What is CatalyzeX?)
DagsHub (What is DagsHub?)
Gotit.pub (What is GotitPub?)
Hugging Face (What is Huggingface?)
Papers with Code (What is Papers with Code?)
ScienceCast (What is ScienceCast?)
Demos
Recommenders and Search Tools
Influence Flower (What are Influence Flowers?)
CORE Recommender (What is CORE?)
arXivLabs: experimental projects with community collaborators
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.