[go: up one dir, main page]
More Web Proxy on the site http://driver.im/ skip to main content
10.1145/2984511.2984574acmconferencesArticle/Chapter ViewAbstractPublication PagesuistConference Proceedingsconference-collections
research-article

Advancing Hand Gesture Recognition with High Resolution Electrical Impedance Tomography

Published: 16 October 2016 Publication History

Abstract

Electrical Impedance Tomography (EIT) was recently employed in the HCI domain to detect hand gestures using an instrumented smartwatch. This prior work demonstrated great promise for non-invasive, high accuracy recognition of gestures for interactive control. We introduce a new system that offers improved sampling speed and resolution. In turn, this enables superior interior reconstruction and gesture recognition. More importantly, we use our new system as a vehicle for experimentation ' we compare two EIT sensing methods and three different electrode resolutions. Results from in-depth empirical evaluations and a user study shed light on the future feasibility of EIT for sensing human input.

Supplementary Material

ZIP File (uist4326-file5.zip)
suppl.mov (uist4326-file3.mp4)
Supplemental video
MP4 File (p843-zhang.mp4)

References

[1]
Ackmann, J.J. 1993. Complex bioelectric impedance measurement system for the frequency range from 5 Hz to 1 MHz. Annals of biomedical engineering 21, 2: 135--146. http://doi.org/10.1007/BF02367609
[2]
Adler, A. and Guardo, R. 1996. Electrical impedance tomography: Regularized imaging and contrast detection. IEEE Transactions on Medical Imaging 15, 2: 170--179. http://doi.org/10.1109/42.491418
[3]
Amento, B., Hill, W. and Terveen, L. 2002. The sound of one hand. In Proc. CHI EA '02, 724. http://dx.doi.org/10.1145/506443.506566
[4]
Amma, C., Krings, T., Böer, J. and Schultz, T. 2015. Advancing Muscle-Computer Interfaces with HighDensity Electromyography. In Proc. CHI '15, 929--938. http://doi.org/10.1145/2702123.2702501
[5]
Analog Devices Inc. 2010. JFET Input Instrumentation Amplifier with Rail-to-Rail Output in MSOP Package. Retrieved July 10, 2016 from http://www.analog.com/media/en/technicaldocumentation/data-sheets/AD8220.pdf
[6]
Analog Devices. 2005. 32-Channel Analog Multiplexer. ADG732. Retrieved July 10, 2016 from http://www.analog.com/media/en/technicaldocumentation/data-sheets/ADG726_732.pdf
[7]
Analog Devices. 2005. Programmable Frequency Sweep and Output Burst Waveform Generator. AD8220. Retrieved July 10, 2016 from http://www.analog.com/media/en/technicaldocumentation/data-sheets/AD8220.pdf
[8]
Aristovich, K.Y., Packham, B.C., Koo, H., Santos, G. S., McEvoy, A. and Holder, D. S. 2016. Imaging fast electrical activity in the brain with electrical impedance tomography. NeuroImage 124: 204--213. http://doi.org/10.1016/j.neuroimage.2015.08.071
[9]
Barber, D.C., Brown, B.H. and Avis, N.J. 1992. Image Reconstruction in Electrical Impedance Tomography Using Filtered Back - Projection. In Proc. EMBS '92, 1691--1692. http://dx.doi.org/10.1109/IEMBS.1992.5761992
[10]
Borcea, L. 2002. Electrical Impedance Tomography. Inverse Problems 18, 6: R99--R136. http://doi.org/10.1088/0266--5611/18/6/201
[11]
Chen, J., Cao, Z. and Xu, L. 2011. Four-terminal scheme used in a two-terminal EIT system. In Proc. IMT '11, 1648'1652. http://doi.org/10.1109/IMTC.2011.5944264
[12]
D'Antona, G., Ferrero, A., Lazzaroni, M., Ottoboni, R. and Samarani, E. 2002. Active monitoring apparatus for underground pollutant detection based on electrical impedance tomography. In Proc. IMTC '02, (IEEE Cat. No.00CH37276) 1, May: 577--579. http://doi.org/10.1109/IMTC.2002.1006906
[13]
Dementyev, A. and Paradiso, J.A. 2014. WristFlex: Low-Power Gesture Input with Wrist-Worn Pressure Sensors. In Proc. UIST '14, 161--166. http://doi.org/10.1145/2642918.2647396
[14]
Deyle, T., Palinko, S., Poole, E.S. and Starner, T. 2007. Hambone: A bio-acoustic gesture interface. In Proc. ISWC '07, 3--10. http://doi.org/10.1109/ISWC.2007.4373768
[15]
Dowrick, T., Blochet, C. and Holder, D. 2015. In vivo bioimpedance measurement of healthy and ischaemic rat brain: implications for stroke imaging using electrical impedance tomography. Physiological Measurement 36, 6: 1273--1282. http://doi.org/10.1088/09673334/36/6/1273
[16]
Dyakowski, T., Jeanmeure, L.F.C. and Jaworski, A.J. 2000. Applications of electrical tomography for gassolids and liquid-solids flows - A review. Powder Technology 112, 3: 174--192. http://doi.org/10.1016/S0032--5910(00)00292--8
[17]
Fukui, R., Watanabe, M., Gyota, T., Shimosaka, M. and Sato, T. 2011. Hand shape classification with a wrist contour sensor. In Proc. UbiComp '11, 311--314. http://doi.org/10.1145/2030112.2030154
[18]
Hall, M., Frank, E., Holmes, G., Pfahringer, B., Reutemann, P. and Witten, I.H. 2009. The WEKA data mining software. ACM SIGKDD Explorations 11, 1: 10--18. http://doi.org/10.1145/1656274.1656278
[19]
Halter, R.L., Hartov, A. and Paulsen, K.D. 2008. Imaging Forearm Blood Flow with Pulse-Ox Gated Electrical Impedance Tomography. In Proc. EMBS'08, 1192--1195. http://doi.org/10.1109/IEMBS.2008.4649376
[20]
Harikumar, R., Prabu, R. and Raghavan, S. 2013. Electrical Impedance Tomography (EIT) and Its Medical Applications'': A Review. International Journal of Soft Computing and Engineering (IJSCE) 3, 4: 193--198.
[21]
Harrison, C., Tan, D. and Morris, D. 2010. Skinput: Appropriating the Body as an Input Surface. In Proc. CHI '10, 453--462. http://doi.org/10.1145/1753326.1753394
[22]
Henderson, R. P. and Webster, J. G. 1978. An impedance camera for spatially specific measurements of the thorax. IEEE transactions on bio-medical engineering 25, 3: 250--254. http://doi.org/10.1109/TBME.1978.326329
[23]
Hilbich, C., Hauck, C., Hoelzle, M., Scherler, M., Schudel, L., Völksch, I., Vonder Mühll, D. and Mäusbacher, R. 2008. Monitoring mountain permafrost evolution using electrical resistivity tomography: A 7-year study of seasonal, annual, and long-term variations at Schilthorn, Swiss Alps. Journal of Geophysical Research: Earth Surface 113, 1: 1--12. http://doi.org/10.1029/2007JF000799
[24]
Holder, D. S. 2015. Electrical Impedance Tomography, Methods, History and Applications. Institute of Physics Publishing. CRC Press: 456. http://doi.org/10.1118/1.1995712
[25]
Holder, D.S. 1992. Electrical impedance tomography (EIT) of brain function. Brain Topography 5, 2: 87--93. http://doi.org/10.1007/BF01129035
[26]
Jung, P.G., Lim, G., Kim, S. and Kong, K. 2015. A Wearable Gesture Recognition Device for Detecting Muscular Activities Based on Air-Pressure Sensors. IEEE Transactions on Industrial Informatics 11, 2: 485--494. http://doi.org/10.1109/TII.2015.2405413
[27]
Kalender, W. 2000. Computed Tomograpy: Fundamentals, System Technology, Image Quality, Applications. Publicis MCD Verlag.
[28]
Kim, D., Hilliges, O. and Izadi, S. 2012. Digits: Freehand 3D Interactions Anywhere Using a Wrist-Worn Gloveless Sensor. In Proc. UIST '12, 167--176. http://doi.org/10.1145/2380116.2380139
[29]
Laput, G., Xiao, R. and Harrison, C. 2016. ViBand: High-Fidelity Bio-Acoustic Sensing Using Commodity Smartwatch Accelerometers. To appear in Proc. UIST '16.
[30]
Lionheart, W.R.B. 2004. EIT Reconstruction Algorithms: Pitfalls, Challenges and Recent Developments. Physiological Measurement 25.1 http://doi.org/10.1088/0967--3334/25/1/021
[31]
Moeller, J. and Kerne, A. 2012. ZeroTouch: an optical multi-touch and free-air interaction architecture. In Proc. CHI '12, 2165--2174. DOI=http://dx.doi.org/10.1145/2207676.2208368
[32]
Rekimoto, J. 2001. GestureWrist and GesturePad: Unobtrusive Wearable Interaction Devices. In Proc. ISWC '01, 21--27. http://dx.doi.org/10.1109/ISWC.2001.962092
[33]
Saponas, T.S., Tan, D.S., Morris, D. and Balakrishnan, R. 2008. Demonstrating the feasibility of using forearm electromyography for muscle-computer interfaces. In Proc. CHI '08, 515--524. http://doi.org/10.1145/1357054.1357138
[34]
Saponas, T.S., Tan, D.S., Morris, D., Balakrishnan, R., Turner, J. and Landay, J.A. Enabling always-available input with muscle-computer interfaces. In Proc. UIST '09, 167--176. http://doi.org/10.1145/1622176.1622208
[35]
Teschner, E., Imhoff, M. and Leonhardt, S. Electrical Impedance Tomography: The realization of regional ventilation monitoring, 2nd Edition.
[36]
Treetronic. 2015. PiCUS: Treetronic, Electric Resistance Tomography. http://www.arguselectronic.de/en/content/download/431/4060/.../ TreeTronic+3+manual.pdf
[37]
Vauhkonen, M., Lionheart, W.R.B., Heikkinen, L.M., Vauhkonen, P.J. and Kaipio, J.P. A MATLAB package for the EIDORS project to reconstruct two-dimensional EIT images. Physiological Measurement 22.1 http://dx.doi.org/10.1088/0967--3334/22/1/314
[38]
Vauhkonen, P.J. 2004. Image Reconstruction in ThreeDimensional Electrical Impedance Tomography.
[39]
Withana, A., Peiris, R., Samarasekara, N. and Nanayakkara, S. zSense: Enabling Shallow Depth Gesture Recognition for Grater Input Expressivity on Smart Wearables. In Proc. CHI '15, 3661--3670. http://dx.doi.org/10.1145/2702123.2702371
[40]
Way, D. and Paradiso, J. A usability user study concerning free-hand microgesture and wrist-worn sensors. In Proc. BSN '14, 138--142. http://dx.doi.org/10.1109/BSN.2014.32
[41]
Wen, H., Rojas, J.R. and Dey, A.K. Serendipity: Finger Gesture Recognition using an Off-the-shelf Smartwatch. In Proc. CHI '16. http://dx.doi.org/10.1145/2858036.2858466
[42]
Wu, K., Yang, J. and Dong, X. 2012. Comparative study of reconstruction algorithms for electrical impedance tomography. IEEE Transactions on Biomedical Engineering, 51077127: 2296--2299.
[43]
Zhang, Y. and Harrison, C. 2015. Tomo: Wearable, Low-Cost Electrical Impedance Tomography for Hand Gesture Recognition. In Proc. UIST '15, 167--173. DOI=http://dx.doi.org/10.1145/2807442.2807480

Cited By

View all
  • (2024)Machine learning-enhanced gesture recognition through impedance signal analysisJournal of Electrical Bioimpedance10.2478/joeb-2024-000715:1(63-74)Online publication date: 11-Jun-2024
  • (2024)Can a Smartwatch Move Your Fingers? Compact and Practical Electrical Muscle Stimulation in a SmartwatchProceedings of the 37th Annual ACM Symposium on User Interface Software and Technology10.1145/3654777.3676373(1-15)Online publication date: 13-Oct-2024
  • (2024)picoRing: battery-free rings for subtle thumb-to-index inputProceedings of the 37th Annual ACM Symposium on User Interface Software and Technology10.1145/3654777.3676365(1-11)Online publication date: 13-Oct-2024
  • Show More Cited By

Index Terms

  1. Advancing Hand Gesture Recognition with High Resolution Electrical Impedance Tomography

    Recommendations

    Comments

    Please enable JavaScript to view thecomments powered by Disqus.

    Information & Contributors

    Information

    Published In

    cover image ACM Conferences
    UIST '16: Proceedings of the 29th Annual Symposium on User Interface Software and Technology
    October 2016
    908 pages
    ISBN:9781450341899
    DOI:10.1145/2984511
    Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

    Sponsors

    Publisher

    Association for Computing Machinery

    New York, NY, United States

    Publication History

    Published: 16 October 2016

    Permissions

    Request permissions for this article.

    Check for updates

    Author Tags

    1. bio-impedance
    2. biometrics
    3. eit
    4. electrical impedance tomography
    5. hand gestures
    6. input
    7. smartwatch

    Qualifiers

    • Research-article

    Conference

    UIST '16

    Acceptance Rates

    UIST '16 Paper Acceptance Rate 79 of 384 submissions, 21%;
    Overall Acceptance Rate 561 of 2,567 submissions, 22%

    Upcoming Conference

    UIST '25
    The 38th Annual ACM Symposium on User Interface Software and Technology
    September 28 - October 1, 2025
    Busan , Republic of Korea

    Contributors

    Other Metrics

    Bibliometrics & Citations

    Bibliometrics

    Article Metrics

    • Downloads (Last 12 months)222
    • Downloads (Last 6 weeks)41
    Reflects downloads up to 01 Mar 2025

    Other Metrics

    Citations

    Cited By

    View all
    • (2024)Machine learning-enhanced gesture recognition through impedance signal analysisJournal of Electrical Bioimpedance10.2478/joeb-2024-000715:1(63-74)Online publication date: 11-Jun-2024
    • (2024)Can a Smartwatch Move Your Fingers? Compact and Practical Electrical Muscle Stimulation in a SmartwatchProceedings of the 37th Annual ACM Symposium on User Interface Software and Technology10.1145/3654777.3676373(1-15)Online publication date: 13-Oct-2024
    • (2024)picoRing: battery-free rings for subtle thumb-to-index inputProceedings of the 37th Annual ACM Symposium on User Interface Software and Technology10.1145/3654777.3676365(1-11)Online publication date: 13-Oct-2024
    • (2024)EchoWrist: Continuous Hand Pose Tracking and Hand-Object Interaction Recognition Using Low-Power Active Acoustic Sensing On a WristbandProceedings of the 2024 CHI Conference on Human Factors in Computing Systems10.1145/3613904.3642910(1-21)Online publication date: 11-May-2024
    • (2024)EITPose: Wearable and Practical Electrical Impedance Tomography for Continuous Hand Pose EstimationProceedings of the 2024 CHI Conference on Human Factors in Computing Systems10.1145/3613904.3642663(1-10)Online publication date: 11-May-2024
    • (2024)Development of a Portable and Low-Cost Data Acquisition System With Edge Intelligence for Electrical Impedance Tomography-Based Spatial Damage DetectionIEEE Transactions on Instrumentation and Measurement10.1109/TIM.2024.347005473(1-11)Online publication date: 2024
    • (2024)Electrical Impedance Tomography for Thorax Image Using Connected Component Labeling and Sparse Group LassoIEEE Transactions on Instrumentation and Measurement10.1109/TIM.2024.342785973(1-12)Online publication date: 2024
    • (2024)A Portable EIT System for Gesture Recognition With Feature Selection and ANN ImplantationIEEE Transactions on Instrumentation and Measurement10.1109/TIM.2024.342037273(1-10)Online publication date: 2024
    • (2024)The Usage of Electroimpedance Tomography along with Artificial Intelligence in Application Development in the field of Medicine2024 32nd Telecommunications Forum (TELFOR)10.1109/TELFOR63250.2024.10819142(1-4)Online publication date: 26-Nov-2024
    • (2024)Multichannel Bioimpedance-Based Gesture Classification System for Enhanced Human-Machine InteractionIEEE Sensors Journal10.1109/JSEN.2024.348069224:23(39699-39709)Online publication date: 1-Dec-2024
    • Show More Cited By

    View Options

    Login options

    View options

    PDF

    View or Download as a PDF file.

    PDF

    eReader

    View online with eReader.

    eReader

    Figures

    Tables

    Media

    Share

    Share

    Share this Publication link

    Share on social media