[go: up one dir, main page]
More Web Proxy on the site http://driver.im/ skip to main content
10.1145/2413097.2413107acmotherconferencesArticle/Chapter ViewAbstractPublication PagespetraConference Proceedingsconference-collections
research-article

Plantar pressure sensing using loop antenna sensors

Published: 06 June 2012 Publication History

Abstract

Foot complications associated with diabetes might lead to foot ulcers. Foot ulcers if neglected can cause foot infection and subsequent amputation. Ulceration is believed to be contributed by stresses acting over the foot. Therefore, measurement of plantar pressures is important in diagnosis and foot ulcer evaluation. However, current plantar pressure measurement systems are either expensive or have a low resolution. This paper investigates the feasibility of employing a loop antenna sensor printed on a dielectric substrate (Rogers 4350B) to detect plantar pressure distribution. This flexible, low profile, inexpensive, high resolution sensor can be easily embedded in shoes to measure the plantar pressures in real-time. The most important advantages of the antenna sensor are they can be multiplexed and wirelessly interrogated. The principal of operation, sensor fabrication, experimental setup, experimental procedure and results are presented. Preliminary results show that the loop antenna sensors have a very low hysteresis loss and respond to pressure with good repeatability. Finally, a technique to wirelessly interrogate the loop antenna sensor is proposed.

References

[1]
Apleqvist, J. 2000. What is the most effective way to reduce incidence of amputation in the diabetic foot?. Diabetic/Metabolism Research and Reviews. 16, s51-s83. DOI = http://dx.doi.org/10.1002/1520-7560(200009/10)16:1+<::AID-DMRR139>3.0.CO;2-8.
[2]
Bernard, T., D'Elia, C., Kabadi, R. and Wong, N. 2009. An early detection system for foot ulceration in diabetic patients. Bioengineering Conference, IEEE 35th Annual Northeast. 1-2. DOI = http:\\dx.doi.org\10.1109/NEBC.2009.4967797.
[3]
Garrow, A. P, Vanschie, C. H. M. and Boulton, A. J. M. 2005. Efficacy of multilayered hosiery in reducing in-shoe plantar foot pressure in high-risk patients with diabetes. Diabetics care. 28. 2001-2006. DOI = http:\\dx.doi.org\10.2337/diacare.28.8.2001.
[4]
Hosein, R., Lord, M. 2000. A study of in-shoe plantar shear in normals. Clinical Biomechanics. 15. n1. 57-64. DOI = http://dx.doi.org/10.1016/S0268-0033(98)00059-X.
[5]
Lord, M. and Hosein, R. 2000. A study of in-shoe plantar shear in patients with diabetic neuropathy. Clinical Biomechanics. 15. n4. 278-283. DOI = http://dx.doi.org/10.1016/S0268-0033(99)00076-5.
[6]
Harris, R. I. and Beath, T. 1947. Army foot survey (National research council of Canada).
[7]
Schwartz, R. P. and Heath, A. L. 1947. The definition of human locomotion on the basis of measurement. J. Bone Joint Surg. 29. 203--214.
[8]
Silvino, N., Evanski, P. M. and Waugh, T. R. 1980. The Harris&Beath foot printing mat: diagnostic validity and clinical use. Clin. Orthop. 151. 453--457.
[9]
Babbs, C. F., Bourland, J. D., Graber, G. P., Jones, J. T. and Schoenlein, W. E. 1990. A pressure-sensitive mat for measuring contact pressure distributions of patients lying on hospital beds. Biomed. Instrum. Technol. 5. 363--370.
[10]
Abhinav, A. K. 2006. Development and characterization of a high-spatial-temporal-resolution-foot-sole-pressure measurement system. M. S. Thesis submitted to the Robotics Institute, Carnegie Mellon University, August 2006.
[11]
Woodburn, J. and Helliwell, P. S. 1996. Observations on the F-Scan in-shoe pressure measuring system. Clin. Biomech. 11. 301-4. DOI = http://dx.doi.org/10.1016/S0268-0033(97)88329-5.
[12]
Wang, W. C., Ledoux, W. R., Sangeorzan, B. J., Reinhall, P. G. 2005. A shear and plantar pressure sensor based on fiberoptic bend loss. Journal of Rehabilitation Research and Development. 42. 315-326. DOI = http://dx.doi.org\10.1109/TBME.2007.912627.
[13]
Deshmukh, S., Mohammad, I., Xu, X. and Huang, H. 2010. Unpowered antenna sensor for crack detection and measurement. Proc. SPIE. 7647. 764742. DOI = http://dx.doi.org/10.1117/12.847573.
[14]
Balanis, C. 2005. Antenna Theory: analysis and design, 3rd edition. Wiley Interscience.
[15]
Rojarayanont, B. and Sekiguchi, T. 1976. One-element loop antenna with finite reflector. Electronics and Communications in Japan. 59-B. 5. 68--75.
[16]
Urry, S. 1999. Plantar pressure-measurement sensors. Meas. Sci. Technol, 10. R16--R32. DOI = http://dx.doi.org\10.1088/0957-0233/10/1/017.
[17]
Katehi, P. and Alexopoulos, N. 1984. On the modeling of electromagnetically coupled microstrip antennas -- the printed strip dipole. IEEE transactions on antennas and propagation. 11. 1179--1186. DOI = http://dx.doi.org\0.1109/TAP.1984.1143235.
[18]
Smith, G. S. 1984. Antenna Engineering Handbook. McGraw Hill

Cited By

View all
  • (2015)An Inductive Sensor for Real-Time Measurement of Plantar Normal and Shear Forces DistributionIEEE Transactions on Biomedical Engineering10.1109/TBME.2014.238613662:5(1316-1323)Online publication date: May-2015

Index Terms

  1. Plantar pressure sensing using loop antenna sensors

    Recommendations

    Comments

    Please enable JavaScript to view thecomments powered by Disqus.

    Information & Contributors

    Information

    Published In

    cover image ACM Other conferences
    PETRA '12: Proceedings of the 5th International Conference on PErvasive Technologies Related to Assistive Environments
    June 2012
    307 pages
    ISBN:9781450313001
    DOI:10.1145/2413097
    Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

    Sponsors

    • U of Tex at Arlington: U of Tex at Arlington

    Publisher

    Association for Computing Machinery

    New York, NY, United States

    Publication History

    Published: 06 June 2012

    Permissions

    Request permissions for this article.

    Check for updates

    Author Tags

    1. foot ulcers
    2. hysteresis
    3. pressure detection
    4. printed loop antenna sensor
    5. quantitative in-shoe pressure detection

    Qualifiers

    • Research-article

    Conference

    PETRA2012
    Sponsor:
    • U of Tex at Arlington

    Contributors

    Other Metrics

    Bibliometrics & Citations

    Bibliometrics

    Article Metrics

    • Downloads (Last 12 months)4
    • Downloads (Last 6 weeks)3
    Reflects downloads up to 26 Dec 2024

    Other Metrics

    Citations

    Cited By

    View all
    • (2015)An Inductive Sensor for Real-Time Measurement of Plantar Normal and Shear Forces DistributionIEEE Transactions on Biomedical Engineering10.1109/TBME.2014.238613662:5(1316-1323)Online publication date: May-2015

    View Options

    Login options

    View options

    PDF

    View or Download as a PDF file.

    PDF

    eReader

    View online with eReader.

    eReader

    Media

    Figures

    Other

    Tables

    Share

    Share

    Share this Publication link

    Share on social media