Abstract
Purpose
Electrophysiological mapping is effective in realizing a precise minimally invasive arrhythmia surgery. Recently, an epicardial electrophysiological mapping system for minimally invasive arrhythmia surgery was reported. The system requires a small electrode array, a tracking system and a global mapping algorithm. The optical tracking system employed in the research requires line of sight and complicated configuration. This paper proposes a new tracking method for locating an electrode array.
Methods
We developed a small electrode array and optical markers. Center points of respective optical markers and the electrode array are tracked via an endoscopic stream and calculated in image space. The orientation of the electrode array is calculated using the dot product between the vector joining two center points of two upper optical markers and the vector joining two end points of the longest edge of the electrode array.
Results
Mean tracking errors of position and orientation of the electrode array were 0.51 mm and 0.64°, respectively. And the processing time was constant at 46 ms per frame. Our method could successfully track the electrode array on the epicardium during in vivo experiment and a global epicardial electrophysiological map was reconstructed from separately measured epicardial electrograms by the small electrode array.
Conclusions
An image-based tracking method for locating an electrode array was proposed. Tracking accuracy, processing time and applicability to surgical environment of our method proved to be acceptable. Consequently, our method enables the electrode array tracking system to be simplified with no separate tracking system.
Similar content being viewed by others
References
Scheinman MM, Morady F, Hess DS, Gonzales R (1982) Catheter-induced ablation of the atrioventricular junction to control refractory supraventricular arrhythmias. JAMA 248: 851–855
Cox JL (2000) The minimally invasive Maze-III procedure. Oper Tech Thorac Cardiovasc Surg 5: 79–92
van Brakel TJ, Bolotin G, Nifong LW et al (2005) Robot-assisted epicardial ablation of the pulmonary veins: is a completed isolation necessary? Eur Heart J 26: 1321–1326
Schilling RJ, Peters NS, Davies DW (1999) Feasibility of a noncontact catheter for endocardial mapping of human ventricular tachycardia. Circulation 99: 2543–2552
Friedman PA (2002) Novel mapping techniques for cardiac electrophysiology. Heart 87: 575–582
Paul T, Windhagen-Mahnert B, Kriebel T, Bertram H, Kaulitz R, Korte T, Niehaus M, Tebbenjohanns J (2001) Atrial reentrant tachycardia after surgery of congenital heart disease: endocardial mapping and radiofrequency catheter ablation using a novel non-contact mapping system. Circulation 103: 2266–2271
Cox JL (2004) Surgical treatment of atrial fibrillation: a review. Europace 5: 20–29
Takata Y (2009) Global epicardial electrophysiological mapping with local multi-channel electrode array. JSCAS 11(1):25–38 (in Japanese)
Raab F, Blood E, Steiner T, Jones T (1979) Magnetic position and orientation tracking system. IEEE Trans Aerosp Electron Syst AES-15(5): 709–718
Nixon MA, McCallum BC, Fright WR, Price NB (1998) The effects of metals and interfering fields on electromagnetic trackers. Presence 7: 204–218
Lowe D (1992) Robust model-based motion tracking through the integration of search and estimation. Int J Comput Vis 8(2): 113–122
Harris C (1992) Tracking with rigid models. In: Blake A, Yuille A (eds) Active vision. MIT Press, Cambridge, pp 59–74
Gennery D (1992) Visual tracking of known three-dimensional objects. Int J Comput Vis 7(3): 243–270
Wang H, Li Z (1997) Tracking a rigid object in 3D from a single camera. Proc SPIE 3185: 78. doi:10.1117/12.284031
Burschka D, Corso JJ, Dewan M, Hager GD, Lau W, Li M, Lin H Marayong P, Ramey N (2004) Navigating inner space: 3-d assistance for minimally invasive surgery. In: Workshop advances in robot vision, IEEE/RSJ internationl conference on intelligent robots and systems, Sendai, Japan, pp 67–78
Casals A, Amat J, Laporte E (1996) Automatic guidance of an assistant robot in laparoscopic surgery. In: Proceedings 1996 IEEE international conference on robotics and automation, vol 1, pp 895–900
Wei GQ, Arbter K, Hirzinger G (1997) Real-time visual servoing for laparoscopic surgery. Controlling robot motion with color image segmentation. IEEE Eng Med Biol Mag 16(1): 40–45
Tonet O, Ramesh TU, Megali G, Dario P (2005) Image analysis-based approach for localization of endoscopic tools. In: Proceedings of the 2nd international conference on computer-aided medical interventions: tools and applications, pp 60–65
Voros S, Orvain E, Cinquin P (2006) Automatic detection of instruments in laparoscopic images: a first step towards high level command of robotized endoscopic holders. In: BIOROB 2006 1st IEEE/RAS-EMBS international conference on biomedical robotics and biomechatronics, Pisa
de Lange P (2009) Condensation algorithm based epicardium tracking. J JSCAS 11(3): 312–313
Zhang Z (2000) A flexible new technique for camera calibration. IEEE Trans Pattern Anal Mach Intell 22(11): 1330–1334
Isard M, Blake A (1998) Condensation—conditional density propagation for visual tracking. Int J Comput Vis 29: 5–28
Nummiaro K, Koller-Meier E, Gool LV (2002) An adaptive color-based particle filter. Image Vis Comput 21(1): 99–110
Pratt W (1991) Digital image processing, 2nd edn. Wiley, New York
Nakamura Y, Kishi K, Kawakami H (2001) Heartbeat synchronization for robotic cardiac surgery. In: Proceedings of the 2001 IEEE international conference on robotics & automation, pp 2014–2019
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kim, H., de Lange, P., Ando, T. et al. Image-based electrode array tracking for epicardial electrophysiological mapping in minimally invasive arrhythmia surgery. Int J CARS 6, 83–92 (2011). https://doi.org/10.1007/s11548-010-0484-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11548-010-0484-x