Abstract
The aim of the study was to examine the influence of the state of the pulp and apical periodontium on the results of electronic root canal length measurement (ERCLM) with a resistance measuring device in dogs. Pulpitis and apical periodontitis were induced by pulp exposure and contamination by the oral flora in the premolar teeth of six mongrel dogs, comprising four experimental groups (36 root canals). In a control group, measured lengths of teeth with uninfected pulps were performed on the first experimental day (44 root canals). In all animals the ERCLMs were performed on teeth with healthy pulps, and at the end of the experimental period (20, 35, 50 and 65 days) following pulp exposure. The point of measuring canal lengths was the anatomical obstacle above the apical delta. Electronically measured lengths (EML) were compared between each other and with the root canal length established by tactile-sense measurement verified radiographically. The EMLs were less accurate in teeth with healthy pulps and teeth with pulpitis in the third experimental group (dif = 2.27 × 2.65 mm2; t test, p < 0.05), while they were most precise after 65 days in teeth with completely necrotic pulp and established chronic apical periodontitis (dif = 0.54 × 1.36 mm2; t test, p > 0.05). These results suggest that the state of the pulp and periapical tissue may have an influence on the ERCLM.
Similar content being viewed by others
References
Abbott PV (1987) Clinical evaluation of an electronic root canal measuring device. Aust Dent J 32:17–21
Burns DH, Mc Donald SGG (1975) Ionska vodljivost. In: Burns DH, Mc Donald SGG (eds) Fizika za biologe i medicinare. Školska knjiga, Zagreb, pp 336–385
Dunlap CA, Remeikis NA, Begole EA, Rauschenberger CR (1998) An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals. J Endodon 24:48–50
Huang L (1987) An experimental study of the principle of electronic root canal measurement. J Endodon 13:60–64
Ingle JI, Himel Van T, Hawrish CE, Glickman GN, Serene T, Rosenberg PA, Buchanan LS, West JD, Ruddle CJ, Camp JH, Roane JB, Cecchini SCM (2002) Endodontic cavity preparation. In: Ingle JI, Bakland LK (eds) Endodontics. BC Decker Inc, London, pp 405–570
Kaufman AY, Keila S, Yoshpe M (2002) Accuracy of a new apex locator: an in vitro study. Int Endod J 35:186–192
Kovačević M, Tamarut T (1998) Influence of the concentration of ions and foramen diameter on the accuracy of the electronic root canal length measurement—an experimental study. J Endodon 24:346–351
Lee SJ, Nam KC, Kim YJ, Kim DW (2002) Clinical accuracy of a new apex locator with and automatic compensation circuit. J Endodon 28:706–709
Meredith N, Gulabivala K (1997) Electrical impedance measurements of root canal length. Endod Dent Traumatol 13:126–131
O’Neill LJ (1973) A clinical evaluation of electronic root canal measurement. Oral Surg 38:469–473
Pahncke D, Voss A (1991) Die Abhängigkeit endometrischer Messungen von den Bedinungen im Wurzelkanal. Dtsch Zahnärztl 46:35–36
Shabahang S,Goon WWY, Gluskin AH (1996) An in vivo evaluation of Root ZX electronic apex locator. J Endodon 22:616–618
Stein TJ,Corcoran JF, Zillich RM (1990) The influence of the major and minor foramen diameters on apical electronic probe measurements. J Endodon 16:520–522
Suchde RV, Talim ST (1977) Electronic ohmmeter. Oral Surg 43:141–150
Sunada I (1962) New method for measuring the length of the root canal. J Dent Res 41:375–387
Tamarut T,Cindrić N, Međugorac G (1988) Qualitative changes of the pulp and multiple electric measurement of the canal. Acta Stomatol Croat 22:45–53
Tamarut T,Cindrić N, Međugorac B, Bertović G (1989) Relationship between ions concentrations: Na+, K+, Ca++, Mg++ and the bioelectrical properties of human dental pulp. Medicina 25:91–97
Tamarut T, Cindrić N, Blašković V, Maričić B (1990) Relationship between alkali metal concentration and electrical properties of human dental pulp. Int Endod J 23:63
Tamarut T, Kovačević M, Uhač I (2000) Detection of a transitional ion concentration zone during electronic measurement of root canal length—a study in vitro. Int Endod J 33:374–380
Tamarut T, Kovačević M, Glavičić S (2006) Influence of the length of instrumentation and canal obturation on the success of endodontic therapy. A ten year clinical follow-up. Am J Dent (in press)
Thomas AS, Hartwell GR, Moon PC (2003) The accuracy of the Root ZX electronic apex locator using stainless-steel and nickel-titanium files. J Endod 29:662–663
Wu JN, Shi JN, Juang LZ, Xu YY (1992) Variables affecting electronic root canal measurement. Int Endod J 25:88–92
Acknowledgments
The authors are grateful to Mrs. Snježana Šimac and Mrs. Marija Mršić, Department of Anatomy, Medical Faculty, University of Rijeka, for their assistance during the laboratory procedures of the experiment. We also wish to thank Prof. Ratko Zelenika, PhD, Head of Department of General Economic theory, Faculty of Economics, University of Rijeka, for his assistance in the preparation of the manuscript.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kovacevic, M., Tamarut, T., Glavičić, S. et al. Electronic root canal length measurement before and after experimentally induced pulpitis and apical periodontitis in dogs. Med Bio Eng Comput 44, 695–701 (2006). https://doi.org/10.1007/s11517-006-0076-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11517-006-0076-7