Evaluation of MR cisternography of the cerebellopontine angle using a balanced fast-field-echo sequence: preliminary findings

  • Neuro
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract

We evaluated the feasibility of MR cisternography by the balanced fast-field-echo (bFFE) sequence, comparing with that by a turbo-spin-echo (TSE) sequence, for cerebellopontine angle lesions on a 1.5-T imager (Gyroscan Intera, Philips, Best, The Netherlands). The bFFE MR cisternograms depicted target cranial nerves with less cerebrospinal fluid pulsation artifacts than TSE cisternograms and visualized an acoustic schwannoma in 6 of 44 patients with suspicion and a causative vessel of hemifacial spasm in all of 3 patients in a short scanning time (1 min 53 s). The bFFE sequence can be promising for MR cisternography in the diagnosis of cerebellopontine angle lesions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
£29.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price includes VAT (United Kingdom)

Instant access to the full article PDF.

Fig. 1a, b
Fig. 2a, b
Fig. 3a–c

Similar content being viewed by others

References

  1. Van der Meulen P, Groen JP, Cuppen JJM (1985) Very fast MR imaging by field echoes and small angle excitation. Magn Reson Imaging 3:297–299

    Google Scholar 

  2. Van der Meulen P, Groen JP, Tinus AMC, Bruntink G (1988) Fast field-echo imaging: an overview and contrast calculations. Magn Reson Imaging 6:365–368

    Google Scholar 

  3. Tsuchiya K, Yamakami N, Hachiya J, Kassai Y (1998) MR cisternography using a three-dimensional half-Fourier single-shot fast spin-echo sequence. Eur Radiol 8:424–426

    Article  PubMed  Google Scholar 

  4. Naganawa S, Koshikawa T, Fukatsu H, Ishigaki T, Fukuta T (2001) MR cisternography of the cerebellopontine angle: comparison of three-dimensional fast asymmetrical spin-echo and three-dimensional constructive interference in the steady-state sequences. Am J Neuroradiol 22:1179–1185

    PubMed  Google Scholar 

  5. Casselman JW, Kuhweide R, Deimling M, Ampe W, Meeus L (1993) Constructive interference in steady-state 3DFT MR imaging of the inner ear and cerebellopontine angle. Am J Neuroradiol 14:47–57

    PubMed  Google Scholar 

  6. Stuckey SL, Harris AJ, Mannolini SM (1996) Detection of acoustic schwannoma: use of constructive interference in the steady-state three-dimensional MR. Am J Neuroradiol 17:1197–1225

    Google Scholar 

  7. Eberhardt KEW, Hollenbach HP, Deimling M, Tomandl BF, Huk WJ (1997) MR cisternography: a new method for the diagnosis of CSF fistulae. Eur Radiol 7:1485–1491

    CAS  PubMed  Google Scholar 

  8. Lee MS, Kim MS, Hong IS, Whang K, Han YP (2001) Clinical usefulness of magnetic resonance cisternography in patients having hemifacial spasm. Yonsei Med J 42:390–394

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kazuhiro Tsuchiya.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tsuchiya, K., Aoki, C. & Hachiya, J. Evaluation of MR cisternography of the cerebellopontine angle using a balanced fast-field-echo sequence: preliminary findings. Eur Radiol 14, 239–242 (2004). https://doi.org/10.1007/s00330-003-2074-6

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00330-003-2074-6

Keywords

Navigation