Abstract
Surgical probes used in nuclear medicine can be maneuvered close to a suspected tumor site, thereby achieving higher resolution and sensitivity than external gamma cameras. Tomography with handheld probes is not possible, however, so it is difficult to determine whether an increase in the photon count rate is caused by features near the probe or by variations in the distant background radiation. Our group has experimented with several probe designs that address this problem. This paper describes a probe that images nearby objects without a collimator and is insensitive to inhomogeneities in the distant background level. The probe, which is used with a radionuclide that emits multiple photons per decay, such as 111In, consists of a collimatorless array of gamma-ray detectors connected by coincidence circuitry. We used a Monte Carlo routine to simulate data collection from such a system and reconstructed the images using the pseudoinverse obtained by singular value decomposition (SVD). The images show a significant suppression of distant sources when compared to a probe equipped with a conventional parallel-hole collimator.
Preview
Unable to display preview. Download preview PDF.
References
Barrett HH, Aarsvold JN and Roney TJ (1991). Null functions and eigenfunctions: tools for the analysis of imaging systems. In: Information Processing in Medical Imaging. Ortendahl DA and Llacer J (eds), Wiley-Liss, New York, pp. 211–226.
Boetticher H, Helmers H, Schreiber P, Schmitz-Feuerhake I (1982). Advances in γ-γ-coincidence scintigraphy with the scintillation camera. Phys. Med. Biol. 27:1495–1506.
Chung V, Chak KC, Zacuto P and Hart HE (1980). Multiple photon coincidence tomography. Semin. Nucl. Med. 10:345–354.
Hartsough NE, Barber HB, Woolfenden JM, Barrett HH, Hickernell HS and Kwo DP (1989). Probes containing gamma radiation detectors for in vivo tumor detection and imaging. Proc. SPIE 1068:92–99.
Hickernell TS (1988). Statistical decision making with a dual-detector probe. Ph.D. Dissertation, University of Arizona.
Hickernell TS, Barber HB, Barrett HH and Woolfenden JM (1988). A dual-detector probe for surgical tumor staging. J. Nucl. Med. 29:1101–1106.
Liang Z and Jaszczak R (1990). Comparisons of multiple photon coincidence imaging techniques. IEEE Trans. Nucl. Sci. 37:1282–1292.
Monahan WG and Powell MD (1973). Three-dimensional imaging of radionuclide distribution by gamma-gamma coincidence detection. In: Tomographic Imaging in Nuclear Medicine. Freedman GS (ed), Society of Nuclear Medicine, New York, pp. 165–175.
Powell MD (1989). Multiphoton, time-of-flight three-dimensional radionuclide imaging. Med. Phys. 16:809–812.
Schmitz-Feuerhake I (1970). Studies on three-dimensional scintigraphy with γ-γ-coincidences. Phys. Med. Biol. 15:649–656.
Woolfenden JM and Barber HB (1989). Radiation detector probes for tumor localization using tumorseeking radioactive tracers. Am. J. Roentgenol. 153:35–39 (invited paper).
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 1991 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Saffer, J.R., Barrett, H.H., Barber, H.B., Woolfenden, J.M. (1991). Surgical probe design for a coincidence imaging system without a collimator. In: Colchester, A.C.F., Hawkes, D.J. (eds) Information Processing in Medical Imaging. IPMI 1991. Lecture Notes in Computer Science, vol 511. Springer, Berlin, Heidelberg. https://doi.org/10.1007/BFb0033738
Download citation
DOI: https://doi.org/10.1007/BFb0033738
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-54246-9
Online ISBN: 978-3-540-47521-7
eBook Packages: Springer Book Archive