Abstract
Accurate quantification of small structures in magnetic resonance (MR) images is often limited by partial volume (PV) effects which arise when more than one tissue type is present in a voxel. PV may be critical when dealing with changes in brain anatomy as the considered structures such as gray matter (GM) are of similar size as the MR spatial resolution. To overcome the limitations imposed by PV effects and achieve subvoxel accuracy different methods have been proposed. Here, we describe a method to compute PV by modeling the MR signal with a biexponential linear combination representing the contribution of at most two tissues in each voxel. In a first step, we estimated the parameters (T1, T2 and proton density) per tissue. Then, based on the bi-exponential formulation one can retrieve fractional contents by solving a linear system of two equations with two unknowns, namely tissue magnetizations. Preliminary tests were conducted on images acquired on a specially designed physical phantom for the study of PV effects. Further, the model was tested on BrainWeb simulated brain images to estimate GM and white matter (WM) PV effects. Root mean squared error was computed between the BrainWeb ground truth and the obtained GM and WM PV maps. The proposed method outperformed traditionally used methods by 33% and 34% in GM and WM, respectively.
Chapter PDF
Similar content being viewed by others
References
Acosta, O., Bourgeat, P., Zuluaga, M.A., Fripp, J., Salvado, O., Ourselin, S.: Automated voxel-based 3D cortical thickness measurement in a combined Lagrangian-Eulerian PDE approach using partial volume maps. Medical Image Analysis 13(5), 730–743 (2009)
Yang, C.-A., Kaveh, M., Erickson, B.J.: Automated Detection of Focal Cortical Dysplasia Lesions on T1-Weighted MRI using Volume-Based Distributional Features. In: 2011 IEEE International Symposium on Biomedical Imaging: From Nano to Macro, pp. 865–870 (2011)
Ballester, A.M., Zisserman, A.P., Brady, M.: Estimation of the partial volume effect in MRI. Medical Image Analysis 6, 389–405 (2002)
Leemput, K.V., Maes, F., Vandermeulen, D., Suetens, P.: Automated Model-Based Tissue Classification of MR Images of the Brain. IEEE Transactions on Medical Imaging 18(10), 897–908 (1999)
Shattuck, D.W., Sandor-leahy, S.R., Schaper, K.A., Rottenberg, D.A., Leahy, R.M.: Magnetic Resonance Image Tissue Classification Using a Partial Volume Model. NeuroImage 13, 856–876 (2001)
Cuadra, M.B., Cammoun, L., Butz, T., Cuisenaire, O., Thiran, J.P.: Comparison and Validation of Tissue Modelization and Statistical Classification Methods in T1-Weighted MR Brain Images. IEEE Transactions on Medical Imaging 24(12), 1548–1565 (2005)
Santago, P., Gage, D.: Statistical models of partial volume effect. IEEE Transactions on Image Processing 4, 1531–1540 (1995)
Tohka, J., Zijdenbos, A., Evans, A.: Fast and robust parameter estimation for statistical partial volume models in brain MRI. NeuroImage 23, 84–97 (2004)
Bricq, S., Collet, C., Armspach, J.: Unifying framework for multimodal brain MRI segmentation based on Hidden Markov Chains. Medical Image Analysis 12, 639–652 (2008)
Thacker, N., Jackson, A., Zhu, X., Li, K.: Accuracy of tissue volume estimation in NMR images. In: Proceedings of MIUA, Leeds, UK (1998)
Rusinek, H., de Leon, M.J., George, A.E., Stylopoulos, L.A., Chandra, R., Smith, G., Rand, T., Mourino, M., Kowalski, H.: Alzheimer disease: Measuring loss of cerebral Gray Matter with MR imaging. Neuroradiology 178, 109–114 (1991)
Tanner, M., Gambarota, G., Kober, T., Krueger, G., Erritzoe, D., Marques, J.P., Newbould, R.: Fluid and white matter suppression with the MP2RAGE sequence. Journal of Magnetic Resonance Imaging 35, 1063–1070 (2011)
Marques, J.P., Kober, T., Krueger, G., van der Zwaag, W., de Moortele, P.F.V., Gruetter, R.: MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field. NeuroImage 49(2), 1271–1281 (2010)
Rooney, W.D., Johnson, G., Li, X., Cohen, E.R., Kim, S.G., Ugurbil, K., Springer, C.S.: Magnetic Field and Tissue Dependencies of Human Brain Longitudinal 1H2O Relaxation in Vivo. Magnetic Resonance in Medicine 57, 308–318 (2007)
Cocosco, C., Kollokian, V., Kwan, R.S., Evans, A.: BrainWeb: Online Interface to a 3D MRI Simulated Brain Database. In: NeuroImage, Proceedings of 3rd International Conference on Functional Mapping of the Human Brain, Copenhagen, vol. 5(4), p. S425 (May 1997)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Duché, Q., Acosta, O., Gambarota, G., Merlet, I., Salvado, O., Saint-Jalmes, H. (2012). Bi-exponential Magnetic Resonance Signal Model for Partial Volume Computation. In: Ayache, N., Delingette, H., Golland, P., Mori, K. (eds) Medical Image Computing and Computer-Assisted Intervention – MICCAI 2012. MICCAI 2012. Lecture Notes in Computer Science, vol 7510. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-33415-3_29
Download citation
DOI: https://doi.org/10.1007/978-3-642-33415-3_29
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-33414-6
Online ISBN: 978-3-642-33415-3
eBook Packages: Computer ScienceComputer Science (R0)