Abstract
The aim of this work is to describe the ongoing development of a non-invasive continuous glucose monitoring system based on Impedance Spectroscopy (IS). Previous work has shown the importance of taking a multi-sensor approach to aid in the compensation of various potentially perturbing parameters, such as the impact of environmental/body temperature, changes in the blood perfusion of the measured skin, underlying tissue volume and changes in the sensor / skin contact due to movements. Here we describe how this multisensor concept has been implemented into an integrated functional model (FM). In our recent studies, this integrated FM has been tested in an experimental clinical study in subject groups with patients with Diabetes type I/II (D) and healthy subjects (ND). The relation between changes in the blood glucose concentration and the impedance of the skin / underlying tissue has been investigated under controlled clinical conditions. The clinical study protocol allowed the use of an intravenous glucose clamp technique to control the subject’s glucose concentration and enabled two hyperglycemic episodes to be achieved within a ten hour study day.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Khalil, OS (2004) Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium. Diabetes Technol Ther 6(5):660-697.
Caduff A, Dewarrat F, Talary MS et al. (2006) Non-invasive glucose monitoring in patients with diabetes: a novel system based on impedance spectroscopy. Biosens Bioelectron 22:598-604
Pfutzner A, Caduff A, Larbig M et al. (2004) Impact of posture and fixation technique on impedance spectroscopy used for continuous and noninvasive glucose monitoring. Diab TechnolTher 6:435-441.
Forst T, Caduff A, Talary M et al. (2006) Impact of Environmental Temperature on Skin Thickness and Microvascular Blood Flow in Subjects With and Without Diabetes. Diab Technol Ther 8:94-101.
Heinemann L and Ampudia-Blasco FJ (1994) Glucose clamps with the Biostator: a critical reappraisal. Horm Metab Res 26:579-583.
Huber D, Städler N, Jonasson L et al. (2007) Multisensor data fusion for non-invasive continuous glucose monitoring, submitted
Adrogue HJ, Madias NE (2000) Hyponatremia. N Engl J Med 342:1581-1589.
Talary MS, Dewarrat F, Huber D et al. (2007) In vivo life sign application of dielectric spectroscopy and non-invasive glucose monitoring. JNCS in press.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2007 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Talary, M., Dewarrat, F., Huber, D., Falco-Jonasson, L., Caduff, A. (2007). Non-Invasive Impedance based Continuous Glucose Monitoring System. In: Scharfetter, H., Merwa, R. (eds) 13th International Conference on Electrical Bioimpedance and the 8th Conference on Electrical Impedance Tomography. IFMBE Proceedings, vol 17. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-73841-1_164
Download citation
DOI: https://doi.org/10.1007/978-3-540-73841-1_164
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-73840-4
Online ISBN: 978-3-540-73841-1
eBook Packages: EngineeringEngineering (R0)