Abstract
High tibial dome osteotomy is a well accepted but technically demanding surgical procedure. Common complications include postoperative malalignment of either under- or over-correction, pin penetration of the tibial plateau, and damage to the tibial dorsal neurovascular structures. In order to address all these problems, we developed a CT-free intraoperative planning and navigation system based on SurgiGATE system (Praxim-Medivision, La Tronche, France). Following acquisition of fluoroscopic images and registration of anatomic landmarks, a patient specific coordinate system is established. The deformity is measured intraoperatively and the surgical procedure is planned interactively. The osteotomy and deformity correction are performed under navigational guidance. The system holds the promise to improve the accuracy, reliability, and safety of this surgical procedure.
Chapter PDF
Similar content being viewed by others
Keywords
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
References
Phillips, M.J., Krackow, K.A.: High Tibial Osteotomy and Distal Femoral Osteotomy for Valgus or Varus Deformity Around the Knee. AAOS Instructional Course Lecture 47, 429–436
Jackson, J.P., Waugh, W.: The Techniques and Complications of Upper Tibial Osteotomy: a Review of 226 Operations. JBJS [Br] 56-B, 236–245 (1974)
Paley, D.: Principles of Deformity Correction. With editorial assistance from Herzenberg. Springer, Heidelberg (2002) ISBN 3-540-41665-X
Hankemeire, S., Paley, D., Pape, H.C., Zeichen, J., Gosling, T., Kretteck, C.: Die Kniegelenknahe Focal-dome-Osteotomie. Orthopäde 33, 170–177 (2004)
Korn, M.: A New Approach to Dome High Tibial Osteotomy. The American Journal of Knee Surgery 9, 13–21 (1996)
Edgar, G.H., Morawski, D.R., Santore, R.F.: Complications of High Tibial Osteotomy. In: FH, F., CD, H., KG, V. (eds.) Knee surgery (1996) ISBN 0-683-03389-1
Fujisawa, Y., Masuhara, R., Shiohi, S.: The Effect of High Tibial Osteotomy on Osteoarthritis of the Knee. Orthop. Clin. North Am. 10, 585–608 (1979)
Noyes, F.R., Barber-Westin, S.D., Hewett, T.E.: High Tibial Osteotomy and Ligament Reconstruction for Varus Angulated Anterior Cruciate Ligament-deficient Knees. The American J. of Sport Medicine 28(3), 282–293 (2000)
Aydogdu, S., Sur, H.: High Tibial Osteotomy for Varus Deformity of More Than 20 Degrees. Rev. Chir. Orthop. Reparatrice Mot. 84, 439–460 (1997)
Takahashi, T., Wada, Y., Tanaka, M., Iwagawa, M., Ikeuchi, M., Hirose, D., Yamamoto, H.: Dome-shaped Proximal Tibial Osteotomy Using Percutaneous Drilling for Osteoarthritis of the Knee. Arch. Orthop Trauma Surg. 120, 32–37 (2000)
Ranjith, M.S., Fiddian, N.J.: Intermediate Follow-up of High Tibial Osteotomy: a Comparison of Two Techniques. Bull. Hosp. Jt. Dis. 61, 11–60 (2002)
Ellis, R.E., Tso, C.Y., Rudan, J.F., Harrison, M.M.: A Surgical Planning and Guidance System for High Tibial Osteotomy. Computer Aided Surgery 4, 264–274 (1999)
Phillips, R., Hafez, M., Mohsen, A., Sheman, K., Hewitt, J., Browbank, I., Bouazza-Marouf, K.: Computer and Robotic Assisted Osteotomy Around the Knee. In: MMVR 2000 - 8th Annual Medicine Meets Virtual Reality Conference, Newport Beach, January 27-30, pp. 265–271 (2000)
Wang, G., Zheng, G., De Simoni, C., Staubli, A., Schmucki, D. Nolte LP.: A Hybrid CT-free Computer Assisted System for High Tibial Osteotomy. In: Langlotz, F., Davies, B.L., Bauer, A. (eds.) Computer Assisted Orthopaedic Surgery, CAOS 2003, Marbella, Spina, p. 394 (2003)
Zheng, G., Marx, A., Langlotz, U., Widmer, K., Buttaro, M.: Nolte LP: A Hybrid CT-free Navigation System for Total Hip Arthroplasty. Computer Assisted Surgery 7, 129–145 (2002)
Kunz, M., Strsuss, M., Langlotz, F., Deuretzbacher, G., Rüther, W., Nolte, LP.: A non-CT Based Total Knee Arthroplasty System Featuring Complete Soft-tissues Balancing. In: Medical Image Computing and Computer-Assisted Intervention, Utrecht, Netherlands, October 14-17 , pp. 409–415 (2001)
Hofstetter, R., Slomczykowski, M., Krettek, C., Koppen, G., Sati, M., Nolte, L.P.: Fluoroscopy as an Imaging Means for Computer Assisted Surgical Navigation. Comp. Aided Surg. 4, 65–76 (1999)
Wang, G., Zheng, G., Keppler, P., Gebhard, F., Staubli, A., Müller, U., Schmucki, D., Flütsch, S., Nolte, L.P.: Implementation, Accuracy Evaluation and Preliminary Clinical Trial of a CTfree Navigation System for High Tibial Opening Wedge Osteotomy. (Submitted to Computer Assisted Surgery)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2004 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Wang, G., Zheng, G., Grützner, P.A., von Recum, J., Nolte, LP. (2004). A CT-Free Intraoperative Planning and Navigation System for High Tibial Dome Osteotomy. In: Barillot, C., Haynor, D.R., Hellier, P. (eds) Medical Image Computing and Computer-Assisted Intervention – MICCAI 2004. MICCAI 2004. Lecture Notes in Computer Science, vol 3217. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-30136-3_75
Download citation
DOI: https://doi.org/10.1007/978-3-540-30136-3_75
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-22977-3
Online ISBN: 978-3-540-30136-3
eBook Packages: Springer Book Archive