Abstract
This paper investigates the hypothesis that a nonlinear relationship exists between photoplethysmography (PPG) and blood pressure (BP) values. Trueness of this hypothesis would imply that, instead of measuring a patient’s BP in an invasive way, this could be indirectly measured by applying a wearable PPG sensor and by using the results of a regression analysis linking PPG and BP. Genetic Programming (GP) is well suited to find the relationship between PPG and BP, because it automatically evolves the structure of the most suitable explicit mathematical model for a regression task. In this paper, for the first time, some preliminary experiments on the use of GP to explicitly relate PPG and BP values have been performed. For both systolic and diastolic BP values, explicit nonlinear mathematical models have been achieved, involving an approximation error of less than 3 mmHg in both cases.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Koza, J.: Genetic Programming: On the Programming of Computers by Means of Natural Selection. MIT Press, Cambridge (1992)
Meigas, K., Lass, J., Karai, D., Kattai, R., Kaik, J.: Pulse wave velocity in continuous blood pressure measurements. In: Magjarevic, R., Nagel, J.H. (eds.) IFMBE Proceedings, vol. 14, pp. 626–629. Springer, New York (2007)
Najjar, S., Scuteri, A., Shetty, V., Wright, J., Muller, D., Fleg, J., Spurgeon, H., Ferrucci, L., Lakatta, E.: Pulse wave velocity is an independent predictor of the longitudinal increase in systolic blood pressure and of incident hypertension in the baltimore longitudinal study of aging. J. Am. Coll. Cardiol. 51(14), 1377–1383 (2008)
Sannino, G., Melillo, P., Stranges, S., De Pietro, G., Pecchia, L.: Blood pressure drop prediction by using HRV measurements in orthostatic hypotension. J. Medical Systems. 39(11), 1–7 (2015)
Inajima, T., Imai, Y., Shuzo, M., Lopez, G., Yanagimoto, S., Iijima, K., Morita, H., Nagai, R., Yahagi, N., Yamada, I.: Relation between blood pressure estimated by pulse wave velocity and directly measured arterial pressure. J. Robot. Mechatron. 24(5), 811–821 (2012)
Gesche, H., Grosskurth, D., Kuechler, G., Patzak, A.: Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method. Eur. J. Appl. Physiol. 112, 309–315 (2012)
Sannino, G., De Falco, I., De Pietro, G.: Non-invasive estimation of blood pressure through genetic programming: preliminary results. In: 8th International Conference on Biomedical Electronics and Devices, pp. 241–249. Scitepress (2015)
Searson, D.: GPTIPS: Genetic Programming and Symbolic Regression for MATLAB (2009). http://gptips.sourceforge.net
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 ICST Institute for Computer Sciences, Social Informatics and Telecommunications Engineering
About this paper
Cite this paper
Sannino, G., De Falco, I., De Pietro, G. (2016). On Evaluating Blood Pressure Through Photoplethysmography. In: Mandler, B., et al. Internet of Things. IoT Infrastructures. IoT360 2015. Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering, vol 169. Springer, Cham. https://doi.org/10.1007/978-3-319-47063-4_57
Download citation
DOI: https://doi.org/10.1007/978-3-319-47063-4_57
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-47062-7
Online ISBN: 978-3-319-47063-4