Abstract
Purpose: Freehand placement of external ventricular drainage is not sufficiently accurate and precise. In the absence of high quality pre-operative 3D images, we propose the use of an average model for guidance of ventricular catheters. Methods: The model was segmented to extract the ventricles and registered to five normal volunteers. The proposed method was validated by comparing the trajectory resulting from the use of the average model to the use of volunteer-specific images. Results: The distances between the target points in the model and the volunteer-specific images at the left and right foramen of Monroe were computed (Mean\(\pm \)std: 5.74\(\pm \)1.39 mm and 6.00\(\pm \)1.17 mm for the left and right side respectively). We also compared the angles between the trajectories resulting from the use of volunteer specific data and the average model and the engagement of the trajectories with the frontal horn of the ipsilateral ventricle. Conclusions: Although an average model for guidance of a surgical procedure has a number of limitations, our initial experiments show that the use of a model might provide sufficient guidance for determination of the angle of insertion. Future work will include further clinical testing and possible refinement of the model.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Toma, A.K., et al.: External ventricular drain insertion accuracy: is there a need for change in practice? Neurosurgery 65(6), 1197–1201 (2009)
Huyette, D.R., et al.: Accuracy of the freehand pass technique for ventriculostomy catheter placement: retrospective assessment using computer tomography scans. J. Neurosurg. 108, 88–91 (2008)
Hayhurst, C., et al.: Effect of electromagnetic-navigated shunt placement on failure rates: a prospective multicenter study. J. Neurosurg. 113, 1273–1278 (2010)
Levitt, M.R., et al.: Image-guided cerebrospinal fluid shunting in children: catheter accuracy and shunt survival. J. Neurosurg. Pediatr. 10, 112–117 (2012)
Kestle, R.W.: Editorial: shunt malfunction. J. Neurosurg. 113, 1270–1272 (2010)
Fonov, V.S., et al.: Unbiased average age-appropriate atlases for pediatric studies. NeuroImage 54(1), 313–327 (2011)
Sadikot, A.F., et al.: Creation of computerized 3D MRI-integrated atlases of the human basal ganglia and thalamus. Front. Syst. Neurosci. 5, 71 (2011)
Krauth, A., et al.: A mean three-dimensional atlas of the human thalamus: generation from multiple histological data. Front. Syst. Neurosci. 49(3), 2053–2062 (2010)
Fischl, B., et al.: Sequence-independent segmentation of magnetic resonance images. NeuroImage 23(Suppl. 1), S69–S84 (2004a)
Pieper, S., et al.: The NA-MIC kit: ITK, VTK, pipelines, grids and 3D slicer as an open platform for the medical image computing community. Proc. IEEE Int. Symp. Biomed. Imaging: From Nano to Macro 1, 698–701 (2006)
Otsu, N.: A threshold selection method from gray-level histograms. IEEE Trans. Syst. Man Cybern. 9(1), 62–66 (1979)
Klein, S., et al.: Elastix: a toolbox for intensity-based medical image registration. IEEE Trans. Med. Imaging. 29, 196–205 (2010)
Ibanez, L., et al.: The ITK Software Guide: The Insight Segmentation and Registration Toolkit. Kitware Inc., New York (2005)
Besl, P.J., et al.: A method for registration of 3D shapes. IEEE Trans. Pattern Anal. Mach. Intell. 14, 239–256 (1992)
Rousseeuw, P.J., et al.: Robust Regression and Outlier Detection. Wiley, New York (1987)
Reinertsen, I., Jakola, A., Solheim, O., Lindseth, F., Unsgård, G.: Model-guided placement of cerebral ventricular catheters. In: Barratt, D., Cotin, S., Fichtinger, G., Jannin, P., Navab, N. (eds.) IPCAI 2013. LNCS, vol. 7915, pp. 30–39. Springer, Heidelberg (2013)
Sarmento, S.A., et al.: Relationship between the coronal suture and the central lobe. Arq. Neuropsiquiatr. 66(4), 868–871 (2008)
Reinertsen, I., et al.: A new system for 3D ultrasound-guided placement of cerebral ventricle catheters. IJCARS 7(1), 151–157 (2012)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer International Publishing Switzerland
About this paper
Cite this paper
Reinertsen, I., Jakola, A.S., Solheim, O., Lindseth, F., Selbekk, T., Unsgaard, G. (2014). Placement of External Ventricular Drains Using an Average Model. In: Erdt, M., et al. Clinical Image-Based Procedures. Translational Research in Medical Imaging. CLIP 2013. Lecture Notes in Computer Science(), vol 8361. Springer, Cham. https://doi.org/10.1007/978-3-319-05666-1_10
Download citation
DOI: https://doi.org/10.1007/978-3-319-05666-1_10
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-05665-4
Online ISBN: 978-3-319-05666-1
eBook Packages: Computer ScienceComputer Science (R0)