[go: up one dir, main page]
More Web Proxy on the site http://driver.im/

Du et al., 2017 - Google Patents

Performance comparison of different readouts for position-sensitive solid-state photomultiplier arrays

Du et al., 2017

View HTML
Document ID
2179798582662670275
Author
Du J
Schmall J
Di K
Yang Y
Dokhale P
Shah K
Cherry S
Publication year
Publication venue
Biomedical physics & engineering express

External Links

Snippet

A thorough comparison of five different readouts for reading out a 2× 2 array of 5 mm× 5 mm position-sensitive solid-state photomultipliers (PS-SSPM) was undertaken. The five readouts include reading out the 20 signals (16 position and 4 timing) individually, two signal …
Continue reading at www.ncbi.nlm.nih.gov (HTML) (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/24Measuring radiation intensity with semiconductor detectors
    • G01T1/241Electrode arrangements, e.g. continuous or parallel strips or the like
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/20Measuring radiation intensity with scintillation detectors
    • G01T1/2006Measuring radiation intensity with scintillation detectors using a combination of a scintillator and photodetector which measures the means radiation intensity
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/20Measuring radiation intensity with scintillation detectors
    • G01T1/2018Scintillation-photodiode combination
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/20Measuring radiation intensity with scintillation detectors
    • G01T1/2008Measuring radiation intensity with scintillation detectors using a combination of different types of scintillation detectors, e.g. phoswich
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/24Measuring radiation intensity with semiconductor detectors
    • G01T1/243Modular detectors, e.g. arrays formed from self contained units
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/29Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
    • G01T1/2914Measurement of spatial distribution of radiation
    • G01T1/2985In depth localisation, e.g. using positron emitters; Tomographic imaging (longitudinal and transverse section imaging; apparatus for radiation diagnosis sequentially in different planes, steroscopic radiation diagnosis)
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/161Application in the field of nuclear medicine, e.g. in vivo counting
    • G01T1/164Scintigraphy
    • G01T1/1641Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras

Similar Documents

Publication Publication Date Title
Cates et al. Evaluation of a clinical TOF-PET detector design that achieves⩽ 100 ps coincidence time resolution
Cates et al. Electronics method to advance the coincidence time resolution with bismuth germanate
Du et al. Performance of a high-resolution depth-encoding PET detector module using linearly-graded SiPM arrays
Kuang et al. Dual-ended readout small animal PET detector by using 0.5 mm pixelated LYSO crystal arrays and SiPMs
Pourashraf et al. Scalable electronic readout design for a 100 ps coincidence time resolution TOF-PET system
Kwon et al. Dual-ended readout of bismuth germanate to improve timing resolution in time-of-flight PET
Downie et al. Investigation of analog charge multiplexing schemes for SiPM based PET block detectors
Chang et al. Time-over-threshold for pulse shape discrimination in a time-of-flight phoswich PET detector
Park et al. Silicon photomultiplier signal readout and multiplexing techniques for positron emission tomography: a review
Park et al. Hybrid charge division multiplexing method for silicon photomultiplier based PET detectors
Ariño-Estrada et al. First Cerenkov charge-induction (CCI) TlBr detector for TOF-PET and proton range verification
Du et al. A depth-of-interaction encoding PET detector module with dual-ended readout using large-area silicon photomultiplier arrays
Ullah et al. Wavelength discrimination (WLD) TOF-PET detector with DOI information
Du et al. Performance comparison of dual-ended readout depth-encoding PET detectors based on BGO and LYSO crystals
Kwon et al. Signal encoding method for a time-of-flight PET detector using a silicon photomultiplier array
Du et al. Performance comparison of depth-encoding detectors based on dual-ended readout and different SiPMs for high-resolution PET applications
Choe et al. Development of capacitive multiplexing circuit for SiPM-based time-of-flight (TOF) PET detector
Lee et al. High-resolution time-of-flight PET detector with 100 ps coincidence time resolution using a side-coupled phoswich configuration
Du et al. Design and evaluation of gapless curved scintillator arrays for simultaneous high-resolution and high-sensitivity brain PET
Ronzhin et al. A SiPM-based TOF-PET detector with high speed digital DRS4 readout
Schmall et al. Comparison of large-area position-sensitive solid-state photomultipliers for small animal PET
Lee et al. Depth-of-interaction measurement in a single-layer crystal array with a single-ended readout using digital silicon photomultiplier
Kang et al. A staggered 3-layer DOI PET detector using BaSO4 reflector for enhanced crystal identification and inter-crystal scattering event discrimination capability
Zhang et al. A thick semi-monolithic scintillator detector for clinical PET scanners
Ko et al. Single transmission-line readout method for silicon photomultiplier based time-of-flight and depth-of-interaction PET