Shi et al., 2021 - Google Patents
Single‐pass metal artifact reduction using a dual‐layer flat panel detectorShi et al., 2021
View PDF- Document ID
- 5338127487976024456
- Author
- Shi L
- Bennett N
- Shiroma A
- Sun M
- Zhang J
- Colbeth R
- Star‐Lack J
- Lu M
- Wang A
- Publication year
- Publication venue
- Medical physics
External Links
Snippet
Purpose Metal artifact remains a challenge in cone‐beam CT images. Many image domain‐ based segmentation methods have been proposed for metal artifact reduction (MAR), which require two‐pass reconstruction. Such methods first segment metal from a first‐pass …
- 239000002184 metal 0 title abstract description 199
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/032—Transmission computed tomography [CT]
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/30—Subject of image; Context of image processing
- G06T2207/30004—Biomedical image processing
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T11/00—2D [Two Dimensional] image generation
- G06T11/003—Reconstruction from projections, e.g. tomography
- G06T11/005—Specific pre-processing for tomographic reconstruction, e.g. calibration, source positioning, rebinning, scatter correction, retrospective gating
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/10—Image acquisition modality
- G06T2207/10072—Tomographic images
- G06T2207/10084—Hybrid tomography; Concurrent acquisition with multiple different tomographic modalities
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/10—Image acquisition modality
- G06T2207/10116—X-ray image
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/48—Diagnostic techniques
- A61B6/481—Diagnostic techniques involving the use of contrast agents
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/48—Diagnostic techniques
- A61B6/482—Diagnostic techniques involving multiple energy imaging
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/58—Testing, adjusting or calibrating devices for radiation diagnosis
- A61B6/582—Calibration
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2211/00—Image generation
- G06T2211/40—Computed tomography
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/50—Clinical applications
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T7/00—Image analysis
- G06T7/0002—Inspection of images, e.g. flaw detection
- G06T7/0012—Biomedical image inspection
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/40—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for generating radiation specially adapted for radiation diagnosis
- A61B6/4007—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for generating radiation specially adapted for radiation diagnosis characterised by using a plurality of source units
- A61B6/4014—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for generating radiation specially adapted for radiation diagnosis characterised by using a plurality of source units arranged in multiple source-detector units
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T5/00—Image enhancement or restoration, e.g. from bit-mapped to bit-mapped creating a similar image
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Schofield et al. | Image reconstruction: Part 1–understanding filtered back projection, noise and image acquisition | |
Veldkamp et al. | Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT | |
Shieh et al. | SPARE: Sparse‐view reconstruction challenge for 4D cone‐beam CT from a 1‐min scan | |
Li et al. | Adaptive nonlocal means filtering based on local noise level for CT denoising | |
Zhao et al. | A model‐based scatter artifacts correction for cone beam CT | |
Bal et al. | Metal artifact reduction in CT using tissue‐class modeling and adaptive prefiltering | |
Abdoli et al. | Metal artifact reduction strategies for improved attenuation correction in hybrid PET/CT imaging | |
Richard et al. | Comparison of model and human observer performance for detection and discrimination tasks using dual‐energy x‐ray images | |
Abdoli et al. | Reduction of dental filling metallic artifacts in CT‐based attenuation correction of PET data using weighted virtual sinograms optimized by a genetic algorithm | |
Zeng et al. | Spectral CT image restoration via an average image-induced nonlocal means filter | |
Niu et al. | Shading correction for on‐board cone‐beam CT in radiation therapy using planning MDCT images | |
Zhu et al. | Scatter correction for cone‐beam CT in radiation therapy | |
Evans et al. | Noise‐resolution tradeoffs in x‐ray CT imaging: a comparison of penalized alternating minimization and filtered backprojection algorithms | |
Won Kim et al. | Realistic simulation of reduced‐dose CT with noise modeling and sinogram synthesis using DICOM CT images | |
Karimi et al. | Segmentation of artifacts and anatomy in CT metal artifact reduction | |
Gao et al. | Scatter correction method for x‐ray CT using primary modulation: phantom studies | |
Speidel et al. | Scanning‐beam digital x‐ray (SBDX) technology for interventional and diagnostic cardiac angiography | |
Jeong et al. | Usefulness of a metal artifact reduction algorithm for orthopedic implants in abdominal CT: phantom and clinical study results | |
Altunbas et al. | A post‐reconstruction method to correct cupping artifacts in cone beam breast computed tomography | |
Sechopoulos | X‐ray scatter correction method for dedicated breast computed tomography | |
Petersilka et al. | Strategies for scatter correction in dual source CT | |
Wu et al. | Metal artifact correction for x‐ray computed tomography using kV and selective MV imaging | |
Gang et al. | Image quality and dose for a multisource cone‐beam CT extremity scanner | |
Lin et al. | An efficient polyenergetic SART (pSART) reconstruction algorithm for quantitative myocardial CT perfusion | |
Söderman et al. | Image quality dependency on system configuration and tube voltage in chest tomosynthesis—a visual grading study using an anthropomorphic chest phantom |