Closed
Description
Describe the bug
Since v0.203.0 I have the strange issue that the battery keeps charging even though there is no solar power left. So it is charging with 4-5kW from the grid for a few minutes. Before v0.203.0 this wasn't the case.
Goodwe Inverter is in General Mode. Without EVCC there is no such behavior.
In one hour the additional grid consumption is at 1,24kWh.
Steps to reproduce
- Update to current version
- Charge a car
- See how battery charges.
Configuration details
open evcc at http://evcc.local:7070
network:
schema: http
host: evcc.local # .local suffix announces the hostname on MDNS
port: 7070
log: debug
levels:
cache: error
# unique installation id
plant: XXX
interval: 10s # control cycle interval
# sponsors can set telemetry: true to enable anonymous data aggregation
# see https://github.com/evcc-io/evcc/discussions/4554
telemetry: false
eebus:
shipid: XXX
certificate:
public: |
-----BEGIN CERTIFICATE-----
XXX
-----END CERTIFICATE-----
private: |
-----BEGIN EC PRIVATE KEY-----
XXX
-----END EC PRIVATE KEY-----
mqtt:
broker: 192.168.169.XXX:1883
user: evcc
password: XXX
topic: evcc
tariffs:
grid:
type: template
template: smartenergy
charges: 0.08 # optional, additional charges per kWh
feedin:
type: fixed
price: 0.07
co2:
type: template
template: electricitymaps-free
token: XXX
zone: AT
solar:
- type: template
template: forecast-solar
lat: XXX
lon: XXX
dec: 30
kwp: 16.125
az: 10
interval: 1h
- type: template
template: forecast-solar
lat: XXX
lon: XXX
dec: 30
kwp: 4.3
az: -80
interval: 1h
- type: template
template: forecast-solar
lat: XXX
lon: XXX
dec: 30
kwp: 3.01
az: 100
interval: 1h
meters:
- name<
E5BA
/span>: grid
type: template
template: homewizard
usage: grid
host: 192.168.169.XXX
- name: huawei
type: custom
power:
source: mqtt
topic: ha/huawei/power
- name: goodwe
type: template
template: goodwe-hybrid
usage: pv
modbus: tcpip
id: 247
host: 192.168.169.XXX
port: 502
- name: goodwe_battery
type: template
template: goodwe-hybrid
usage: battery
modbus: tcpip
id: 247
host: 192.168.169.XXX
port: 502
- name: wallbox-garage-meter
type: custom
power:
source: mqtt
topic: wbec/lp/1/power
energy:
source: mqtt
topic: wbec/lp/1/energy
currents:
- source: mqtt
topic: wbec/lp/1/currL1
- source: mqtt
topic: wbec/lp/1/currL2
- source: mqtt
topic: wbec/lp/1/currL3
- name: wallbox-einfahrt-meter
type: template
template: eastron
usage: charge
modbus: rs485tcpip
id: 1
host: 192.168.169.XXX
port: 502
- name: wallbox-strasse-meter
type: template
template: eastron
usage: charge
modbus: rs485tcpip
id: 2
host: 192.168.169.XXX
port: 502
chargers:
- type: custom
name: wallbox-garage
status:
source: mqtt
topic: wbec/lp/1/status
enabled:
source: mqtt
topic: wbec/lp/1/enabled
enable:
source: mqtt
topic: wbec/lp/1/enable
maxcurrent:
source: mqtt
topic: wbec/lp/1/maxcurrent
- type: custom
name: wallbox-einfahrt
status:
source: mqtt
topic: wbec/lp/2/status
enabled:
source: mqtt
topic: wbec/lp/2/enabled
enable:
source: mqtt
topic: wbec/lp/2/enable
maxcurrent:
source: mqtt
topic: wbec/lp/2/maxcurrent
- type: custom
name: wallbox-strasse
status:
source: mqtt
topic: wbec/lp/3/status
enabled:
source: mqtt
topic: wbec/lp/3/enabled
enable:
source: mqtt
topic: wbec/lp/3/enable
maxcurrent:
source: mqtt
topic: wbec/lp/3/maxcurrent
vehicles:
- type: template
template: evnotify
title: Hailey
akey: XXX
token: XXX
capacity: 28.2
name: ev3
phases: 1
priority: 9
- type: custom
title: Nora
capacity: 13
name: ev2
phases: 1
onIdentify:
priority: 10
soc:
source: mqtt
topic: ha/leafspy/soc
status:
source: mqtt
topic: ha/leafspy/status
odometer:
source: mqtt
topic: ha/leafspy/odometer
features: ["coarsecurrent"]
- type: template
template: teslamate
title: Toni
name: ev1
capacity: 62
id: 1
priority: 8
- type: template
template: offline
name: ev4
title: Emilia
capacity: 38
phases: 1
priority: 9
loadpoints:
- title: Garage
charger: wallbox-garage
vehicle: ev1
mode: pv
phases: 3
mincurrent: 6
maxcurrent: 16
meter: wallbox-garage-meter
priority: 0
- title: Einfahrt
charger: wallbox-einfahrt
mode: pv
phases: 3
mincurrent: 6
maxcurrent: 16
meter: wallbox-einfahrt-meter
circuit: outdoor
priority: 0
- title: Strasse
charger: wallbox-strasse
mode: pv
phases: 3
mincurrent: 6
maxcurrent: 16
meter: wallbox-strasse-meter
circuit: outdoor
priority: 0
circuits:
- name: main
title: Hauptstromkreis
maxPower: 5000
meter: grid
- name: outdoor
title: Straße
maxPower: 22000
parent: main
site:
title: Amon's Haus
meters:
grid: grid
pv:
- huawei
- goodwe
battery:
- goodwe_battery
residualPower: 150
Log details
[site ] DEBUG 2025/06/17 11:30:08 ----
[lp-1 ] DEBUG 2025/06/17 11:30:08 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:30:08 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:30:08 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:30:08 charge power: 3400W
[lp-3 ] DEBUG 2025/06/17 11:30:08 charge currents: [0 0 0.0491]A
[lp-2 ] DEBUG 2025/06/17 11:30:08 charge currents: [0 15.2 0.0501]A
[circuit-outdoor] DEBUG 2025/06/17 11:30:08 power: 3405.6W
[circuit-outdoor] DEBUG 2025/06/17 11:30:08 current: 15.3A
[circuit-main] DEBUG 2025/06/17 11:30:08 power: 4974W
[circuit-main] DEBUG 2025/06/17 11:30:08 current: 17.8A
[site ] DEBUG 2025/06/17 11:30:08 grid power: 4974W
[site ] DEBUG 2025/06/17 11:30:08 grid currents: [17.8 2.3 4.3]A
[site ] DEBUG 2025/06/17 11:30:08 pv 1 power: 3514W
[site ] DEBUG 2025/06/17 11:30:09 battery 1 power: -5168W
[site ] DEBUG 2025/06/17 11:30:09 pv 2 power: 1523W
[site ] DEBUG 2025/06/17 11:30:09 battery 1 soc: 46%
[site ] DEBUG 2025/06/17 11:30:09 pv power: 5037W
[site ] DEBUG 2025/06/17 11:30:09 site power: -44W
[lp-3 ] DEBUG 2025/06/17 11:30:09 charge voltages: [237 227 238]V
[lp-3 ] DEBUG 2025/06/17 11:30:09 detected connected phases: 3p
[lp-3 ] DEBUG 2025/06/17 11:30:09 charge total import: 3018.109kWh
[lp-3 ] DEBUG 2025/06/17 11:30:09 charger status: B
[lp-3 ] DEBUG 2025/06/17 11:30:09 pv charge current: 0.0638A = 0A + 0.0638A (-44W @ 3p)
[site ] DEBUG 2025/06/17 11:30:09 solar forecast: accumulated 8.625kWh, produced 23.860kWh, scale 2.766
[site ] DEBUG 2025/06/17 11:30:18 ----
[lp-1 ] DEBUG 2025/06/17 11:30:18 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:30:18 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:30:18 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:30:18 charge power: 3406W
[lp-3 ] DEBUG 2025/06/17 11:30:18 charge currents: [0 0 0.0497]A
[lp-2 ] DEBUG 2025/06/17 11:30:18 charge currents: [0 15.2 0.0501]A
[circuit-outdoor] DEBUG 2025/06/17 11:30:18 power: 3411.6W
[circuit-outdoor] DEBUG 2025/06/17 11:30:18 current: 15.3A
[circuit-main] WARN 2025/06/17 11:30:18 over power detected: 5004W > 5000W
[circuit-main] DEBUG 2025/06/17 11:30:18 current: 17.7A
[site ] DEBUG 2025/06/17 11:30:18 grid power: 5004W
[site ] DEBUG 2025/06/17 11:30:18 grid currents: [17.7 2.4 4.3]A
[site ] DEBUG 2025/06/17 11:30:18 pv 1 power: 3514W
[site ] DEBUG 2025/06/17 11:30:19 battery 1 power: -5109W
[site ] DEBUG 2025/06/17 11:30:19 pv 2 power: 1457W
[site ] DEBUG 2025/06/17 11:30:19 battery 1 soc: 46%
[site ] DEBUG 2025/06/17 11:30:19 pv power: 4971W
[site ] DEBUG 2025/06/17 11:30:19 site power: 45W
[lp-1 ] DEBUG 2025/06/17 11:30:19 charge total import: 0.000kWh
[lp-1 ] DEBUG 2025/06/17 11:30:19 charger status: A
[site ] DEBUG 2025/06/17 11:30:19 solar forecast: accumulated 8.641kWh, produced 23.969kWh, scale 2.774
[site ] DEBUG 2025/06/17 11:30:28 ----
[lp-1 ] DEBUG 2025/06/17 11:30:28 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:30:28 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:30:28 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:30:28 charge power: 3425W
[lp-2 ] DEBUG 2025/06/17 11:30:28 charge currents: [0 15.3 0.0504]A
[lp-3 ] DEBUG 2025/06/17 11:30:28 charge currents: [0 0 0.049]A
[circuit-outdoor] DEBUG 2025/06/17 11:30:28 power: 3430W
[circuit-outdoor] DEBUG 2025/06/17 11:30:28 current: 15.4A
[circuit-main] DEBUG 2025/06/17 11:30:28 power: 4977W
[circuit-main] DEBUG 2025/06/17 11:30:28 current: 17.7A
[site ] DEBUG 2025/06/17 11:30:28 grid power: 4977W
[site ] DEBUG 2025/06/17 11:30:28 grid currents: [17.7 2.3 4.3]A
[site ] DEBUG 2025/06/17 11:30:28 pv 1 power: 3308W
[site ] DEBUG 2025/06/17 11:30:29 battery 1 power: -5036W
[site ] DEBUG 2025/06/17 11:30:29 battery 1 soc: 46%
[site ] DEBUG 2025/06/17 11:30:29 pv 2 power: 1441W
[site ] DEBUG 2025/06/17 11:30:29 pv power: 4749W
[site ] DEBUG 2025/06/17 11:30:29 site power: 91W
[lp-2 ] DEBUG 2025/06/17 11:30:29 charge voltages: [237 227 238]V
[lp-2 ] DEBUG 2025/06/17 11:30:29 detected connected phases: 3p
[lp-2 ] DEBUG 2025/06/17 11:30:29 detected active phases: 1p
[lp-2 ] DEBUG 2025/06/17 11:30:29 charge total import: 4851.187kWh
[lp-2 ] DEBUG 2025/06/17 11:30:29 charger status: C
[lp-2 ] ERROR 2025/06/17 11:30:29 vehicle soc: outdated
[lp-2 ] DEBUG 2025/06/17 11:30:29 pv charge current: 14.6A = 15A + -0.396A (91W @ 1p)
[lp-2 ] DEBUG 2025/06/17 11:30:29 set charge current limit: 14A
[site ] DEBUG 2025/06/17 11:30:29 solar forecast: accumulated 8.658kWh, produced 23.978kWh, scale 2.770
[site ] DEBUG 2025/06/17 11:30:38 ----
[lp-1 ] DEBUG 2025/06/17 11:30:38 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:30:38 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:30:38 charge power: 5W
[lp-2 ] DEBUG 2025/06/17 11:30:38 charge power: 3170W
[lp-3 ] DEBUG 2025/06/17 11:30:38 charge currents: [0 0 0.0491]A
[lp-2 ] DEBUG 2025/06/17 11:30:38 charge currents: [0 14.1 0.0467]A
[circuit-outdoor] DEBUG 2025/06/17 11:30:38 power: 3175.8W
[circuit-outdoor] DEBUG 2025/06/17 11:30:38 current: 14.2A
[circuit-main] DEBUG 2025/06/17 11:30:38 power: 4768W
[circuit-main] DEBUG 2025/06/17 11:30:38 current: 16.7A
[site ] DEBUG 2025/06/17 11:30:38 grid power: 4768W
[site ] DEBUG 2025/06/17 11:30:38 grid currents: [16.7 2.3 4.3]A
[site ] DEBUG 2025/06/17 11:30:38 pv 1 power: 3308W
[site ] DEBUG 2025/06/17 11:30:39 battery 1 power: -4973W
[site ] DEBUG 2025/06/17 11:30:39 pv 2 power: 1430W
[site ] DEBUG 2025/06/17 11:30:39 battery 1 soc: 46%
[site ] DEBUG 2025/06/17 11:30:39 pv power: 4738W
[site ] DEBUG 2025/06/17 11:30:39 site power: -55W
[lp-3 ] DEBUG 2025/06/17 11:30:39 charge voltages: [237 228 237]V
[lp-3 ] DEBUG 2025/06/17 11:30:39 detected connected phases: 3p
[lp-3 ] DEBUG 2025/06/17 11:30:39 charge total import: 3018.109kWh
[lp-3 ] DEBUG 2025/06/17 11:30:39 charger status: B
[lp-3 ] DEBUG 2025/06/17 11:30:39 pv charge current: 0.0797A = 0A + 0.0797A (-55W @ 3p)
[site ] DEBUG 2025/06/17 11:30:39 solar forecast: accumulated 8.674kWh, produced 23.988kWh, scale 2.766
[site ] DEBUG 2025/06/17 11:30:48 ----
[lp-1 ] DEBUG 2025/06/17 11:30:48 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:30:48 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:30:48 charge power: 5W
[lp-2 ] DEBUG 2025/06/17 11:30:48 charge power: 3171W
[lp-3 ] DEBUG 2025/06/17 11:30:48 charge currents: [0 0 0.0489]A
[lp-2 ] DEBUG 2025/06/17 11:30:48 charge currents: [0 14.1 0.0466]A
[circuit-outdoor] DEBUG 2025/06/17 11:30:48 power: 3176W
[circuit-outdoor] DEBUG 2025/06/17 11:30:48 current: 14.2A
[circuit-main] DEBUG 2025/06/17 11:30:48 power: 4861W
[circuit-main] DEBUG 2025/06/17 11:30:48 current: 16.8A
[site ] DEBUG 2025/06/17 11:30:48 grid power: 4861W
[site ] DEBUG 2025/06/17 11:30:48 grid currents: [16.8 2.5 4.3]A
[site ]
F846
DEBUG 2025/06/17 11:30:48 pv 1 power: 3308W
[site ] DEBUG 2025/06/17 11:30:49 battery 1 power: -4893W
[site ] DEBUG 2025/06/17 11:30:49 battery 1 soc: 46%
[site ] DEBUG 2025/06/17 11:30:49 pv 2 power: 1410W
[site ] DEBUG 2025/06/17 11:30:49 pv power: 4718W
[site ] DEBUG 2025/06/17 11:30:49 site power: 118W
[lp-1 ] DEBUG 2025/06/17 11:30:49 charge total import: 0.000kWh
[lp-1 ] DEBUG 2025/06/17 11:30:49 charger status: A
[site ] DEBUG 2025/06/17 11:30:49 solar forecast: accumulated 8.689kWh, produced 23.997kWh, scale 2.762
[site ] DEBUG 2025/06/17 11:30:58 ----
[lp-1 ] DEBUG 2025/06/17 11:30:58 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:30:58 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:30:58 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:30:58 charge power: 3185W
[lp-2 ] DEBUG 2025/06/17 11:30:58 charge currents: [0 14.2 0.0462]A
[lp-3 ] DEBUG 2025/06/17 11:30:58 charge currents: [0 0 0.0494]A
[circuit-outdoor] DEBUG 2025/06/17 11:30:58 power: 3190.4W
[circuit-outdoor] DEBUG 2025/06/17 11:30:58 current: 14.3A
[circuit-main] DEBUG 2025/06/17 11:30:59 power: 4818W
[circuit-main] DEBUG 2025/06/17 11:30:59 current: 16.8A
[site ] DEBUG 2025/06/17 11:30:59 grid power: 4818W
[site ] DEBUG 2025/06/17 11:30:59 grid currents: [16.8 2.5 4.3]A
[site ] DEBUG 2025/06/17 11:30:59 pv 1 power: 3161W
[site ] DEBUG 2025/06/17 11:30:59 battery 1 power: -4840W
[site ] DEBUG 2025/06/17 11:30:59 battery 1 soc: 46%
[site ] DEBUG 2025/06/17 11:30:59 pv 2 power: 1384W
[site ] DEBUG 2025/06/17 11:30:59 pv power: 4545W
[site ] DEBUG 2025/06/17 11:30:59 site power: 128W
[lp-2 ] DEBUG 2025/06/17 11:30:59 charge voltages: [237 228 237]V
[lp-2 ] DEBUG 2025/06/17 11:30:59 detected connected phases: 3p
[lp-2 ] DEBUG 2025/06/17 11:30:59 detected active phases: 1p
[lp-2 ] DEBUG 2025/06/17 11:31:00 charge total import: 4851.214kWh
[lp-2 ] DEBUG 2025/06/17 11:31:00 charger status: C
[lp-2 ] ERROR 2025/06/17 11:31:00 vehicle soc: outdated
[lp-2 ] DEBUG 2025/06/17 11:31:00 pv charge current: 13.4A = 14A + -0.557A (128W @ 1p)
[lp-2 ] DEBUG 2025/06/17 11:31:00 set charge current limit: 13A
[site ] DEBUG 2025/06/17 11:31:00 solar forecast: accumulated 8.707kWh, produced 24.006kWh, scale 2.757
[site ] DEBUG 2025/06/17 11:31:08 ----
[lp-1 ] DEBUG 2025/06/17 11:31:08 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:31:08 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:31:08 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:31:08 charge power: 2967W
[lp-3 ] DEBUG 2025/06/17 11:31:08 charge currents: [0 0 0.0492]A
[lp-2 ] DEBUG 2025/06/17 11:31:08 charge currents: [0 13.2 0]A
[circuit-outdoor] DEBUG 2025/06/17 11:31:08 power: 2972.9W
[circuit-outdoor] DEBUG 2025/06/17 11:31:08 current: 13.2A
[circuit-main] DEBUG 2025/06/17 11:31:08 power: 4581W
[circuit-main] DEBUG 2025/06/17 11:31:08 current: 15.7A
[site ] DEBUG 2025/06/17 11:31:08 grid power: 4581W
[site ] DEBUG 2025/06/17 11:31:08 grid currents: [15.7 2.5 4.4]A
[site ] DEBUG 2025/06/17 11:31:08 pv 1 power: 3161W
[site ] DEBUG 2025/06/17 11:31:09 battery 1 power: -4792W
[site ] DEBUG 2025/06/17 11:31:09 battery 1 soc: 46%
[site ] DEBUG 2025/06/17 11:31:09 pv 2 power: 1370W
[site ] DEBUG 2025/06/17 11:31:09 pv power: 4531W
[site ] DEBUG 2025/06/17 11:31:09 site power: -61W
[lp-3 ] DEBUG 2025/06/17 11:31:09 charge voltages: [236 229 237]V
[lp-3 ] DEBUG 2025/06/17 11:31:09 detected connected phases: 3p
[lp-3 ] DEBUG 2025/06/17 11:31:09 charge total import: 3018.109kWh
[lp-3 ] DEBUG 2025/06/17 11:31:09 charger status: B
[lp-3 ] DEBUG 2025/06/17 11:31:09 pv charge current: 0.0884A = 0A + 0.0884A (-61W @ 3p)
[site ] DEBUG 2025/06/17 11:31:09 solar forecast: accumulated 8.722kWh, produced 24.014kWh, scale 2.753
[site ] DEBUG 2025/06/17 11:31:18 ----
[lp-1 ] DEBUG 2025/06/17 11:31:18 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:31:18 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:31:18 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:31:18 charge power: 2965W
[lp-3 ] DEBUG 2025/06/17 11:31:18 charge currents: [0 0 0.0488]A
[lp-2 ] DEBUG 2025/06/17 11:31:18 charge currents: [0 13.2 0]A
[circuit-outdoor] DEBUG 2025/06/17 11:31:18 power: 2970.6W
[circuit-outdoor] DEBUG 2025/06/17 11:31:18 current: 13.2A
[circuit-main] DEBUG 2025/06/17 11:31:18 power: 4590W
[circuit-main] DEBUG 2025/06/17 11:31:18 current: 15.8A
[site ] DEBUG 2025/06/17 11:31:18 grid power: 4590W
[site ] DEBUG 2025/06/17 11:31:18 grid currents: [15.8 2.5 4.3]A
[site ] DEBUG 2025/06/17 11:31:18 pv 1 power: 3161W
[site ] DEBUG 2025/06/17 11:31:19 battery 1 power: -4792W
[site ] DEBUG 2025/06/17 11:31:19 pv 2 power: 1384W
[site ] DEBUG 2025/06/17 11:31:19 pv power: 4545W
[site ] DEBUG 2025/06/17 11:31:19 battery 1 soc: 46%
[site ] DEBUG 2025/06/17 11:31:19 site power: -52W
[lp-1 ] DEBUG 2025/06/17 11:31:19 charge total import: 0.000kWh
[lp-1 ] DEBUG 2025/06/17 11:31:19 charger status: A
[site ] DEBUG 2025/06/17 11:31:19 solar forecast: accumulated 8.738kWh, produced 24.023kWh, scale 2.749
[site ] DEBUG 2025/06/17 11:31:28 ----
[lp-1 ] DEBUG 2025/06/17 11:31:28 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:31:28 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:31:28 charge power: 5W
[lp-2 ] DEBUG 2025/06/17 11:31:28 charge power: 2962W
[lp-3 ] DEBUG 2025/06/17 11:31:28 charge currents: [0 0 0.0487]A
[lp-2 ] DEBUG 2025/06/17 11:31:28 charge currents: [0 13.2 0]A
[circuit-outdoor] DEBUG 2025/06/17 11:31:28 power: 2967.9W
[circuit-outdoor] DEBUG 2025/06/17 11:31:28 current: 13.2A
[circuit-main] DEBUG 2025/06/17 11:31:28 power: 4587W
[circuit-main] DEBUG 2025/06/17 11:31:28 current: 15.7A
[site ] DEBUG 2025/06/17 11:31:28 grid power: 4587W
[site ] DEBUG 2025/06/17 11:31:28 grid currents: [15.7 2.5 4.3]A
[site ] DEBUG 2025/06/17 11:31:28 pv 1 power: 3068W
[site ] DEBUG 2025/06/17 11:31:29 battery 1 power: -4764W
[site ] DEBUG 2025/06/17 11:31:29 battery 1 soc: 46%
[site ] DEBUG 2025/06/17 11:31:29 pv 2 power: 1363W
[site ] DEBUG 2025/06/17 11:31:29 pv power: 4431W
[site ] DEBUG 2025/06/17 11:31:29 site power: -27W
[lp-2 ] DEBUG 2025/06/17 11:31:29 charge voltages: [236 228 238]V
[lp-2 ] DEBUG 2025/06/17 11:31:29 detected connected phases: 3p
[lp-2 ] DEBUG 2025/06/17 11:31:29 detected active phases: 1p
[lp-2 ] DEBUG 2025/06/17 11:31:29 charge total import: 4851.239kWh
[lp-2 ] DEBUG 2025/06/17 11:31:29 charger status: C
[lp-2 ] ERROR 2025/06/17 11:31:29 vehicle soc: outdated
[lp-2 ] DEBUG 2025/06/17 11:31:29 pv charge current: 13.1A = 13A + 0.117A (-27W @ 1p)
[site ] DEBUG 2025/06/17 11:31:29 solar forecast: accumulated 8.755kWh, produced 24.032kWh, scale 2.745
[site ] DEBUG 2025/06/17 11:31:38 ----
[lp-1 ] DEBUG 2025/06/17 11:31:38 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:31:38 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:31:38 charge power: 5W
[lp-2 ] DEBUG 2025/06/17 11:31:38 charge power: 2967W
[lp-3 ] DEBUG 2025/06/17 11:31:38 charge currents: [0 0 0.0489]A
[lp-2 ] DEBUG 2025/06/17 11:31:38 charge currents: [0 13.2 0]A
[circuit-outdoor] DEBUG 2025/06/17 11:31:38 power: 2972.5W
[circuit-outdoor] DEBUG 2025/06/17 11:31:38 current: 13.2A
[circuit-main] DEBUG 2025/06/17 11:31:38 power: 4571W
[circuit-main] DEBUG 2025/06/17 11:31:38 current: 15.7A
[site ] DEBUG 2025/06/17 11:31:38 grid power: 4571W
[site ] DEBUG 2025/06/17 11:31:38 grid currents: [15.7 2.5 4.3]A
[site ] DEBUG 2025/06/17 11:31:38 pv 1 power: 3068W
[site ] DEBUG 2025/06/17 11:31:39 battery 1 power: -4752W
[site ] DEBUG 2025/06/17 11:31:39 pv 2 power: 1367W
[site ] DEBUG 2025/06/17 11:31:39 battery 1 soc: 46%
[site ] DEBUG 2025/06/17 11:31:39 pv power: 4435W
[site ] DEBUG 2025/06/17 11:31:39 site power: -31W
[lp-3 ] DEBUG 2025/06/17 11:31:39 charge voltages: [236 228 238]V
[lp-3 ] DEBUG 2025/06/17 11:31:39 detected connected phases: 3p
[lp-3 ] DEBUG 2025/06/17 11:31:39 charge total import: 3018.109kWh
[lp-3 ] DEBUG 2025/06/17 11:31:39 charger status: B
[lp-3 ] DEBUG 2025/06/17 11:31:39 pv charge current: 0.0449A = 0A + 0.0449A (-31W @ 3p)
[site ] DEBUG 2025/06/17 11:31:39 solar forecast: accumulated 8.771kWh, produced 24.040kWh, scale 2.741
[site ] DEBUG 2025/06/17 11:31:48 ----
[lp-1 ] DEBUG 2025/06/17 11:31:48 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:31:48 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:31:48 charge power: 5W
[lp-2 ] DEBUG 2025/06/17 11:31:48 charge power: 2961W
[lp-2 ] DEBUG 2025/06/17 11:31:48 charge currents: [0 13.2 0]A
[lp-3 ] DEBUG 2025/06/17 11:31:48 charge currents: [0 0 0.0497]A
[circuit-outdoor] DEBUG 2025/06/17 11:31:48 power: 2966W
[circuit-outdoor] DEBUG 2025/06/17 11:31:48 current: 13.2A
[circuit-main] DEBUG 2025/06/17 11:31:48 power: 4566W
[circuit-main] DEBUG 2025/06/17 11:31:48 current: 15.7A
[site ] DEBUG 2025/06/17 11:31:48 grid power: 4566W
[site ] DEBUG 2025/06/17 11:31:48 grid currents: [15.7 2.5 4.3]A
[site ] DEBUG 2025/06/17 11:31:48 pv 1 power: 3068W
[site ] DEBUG 2025/06/17 11:31:49 battery 1 power: -4791W
[site ] DEBUG 2025/06/17 11:31:49 battery 1 soc: 46%
[site ] DEBUG 2025/06/17 11:31:49 pv 2 power: 1363W
[site ] DEBUG 2025/06/17 11:31:49 pv power: 4431W
[site ] DEBUG 2025/06/17 11:31:49 site power: -75W
[lp-1 ] DEBUG 2025/06/17 11:31:49 charge total import: 0.000kWh
[lp-1 ] DEBUG 2025/06/17 11:31:49 charger status: A
[site ] DEBUG 2025/06/17 11:31:49 solar forecast: accumulated 8.787kWh, produced 24.049kWh, scale 2.737
[site ] DEBUG 2025/06/17 11:31:58 ----
[lp-1 ] DEBUG 2025/06/17 11:31:58 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:31:58 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:31:58 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:31:58 charge power: 2979W
[lp-3 ] DEBUG 2025/06/17 11:31:58 charge currents: [0 0 0.0496]A
[lp-2 ] DEBUG 2025/06/17 11:31:58 charge currents: [0 13.2 0]A
[circuit-outdoor] DEBUG 2025/06/17 11:31:58 power: 2984.2W
[circuit-outdoor] DEBUG 2025/06/17 11:31:58 current: 13.2A
[circuit-main] DEBUG 2025/06/17 11:31:58 power: 4550W
[circuit-main] DEBUG 2025/06/17 11:31:58 current: 15.6A
[site ] DEBUG 2025/06/17 11:31:58 grid power: 4550W
[site ] DEBUG 2025/06/17 11:31:58 grid currents: [15.6 2.5 4.3]A
[site ] DEBUG 2025/06/17 11:31:58 pv 1 power: 3061W
[site ] DEBUG 2025/06/17 11:31:59 battery 1 power: -4908W
[site ] DEBUG 2025/06/17 11:31:59 battery 1 soc: 46%
[site ] DEBUG 2025/06/17 11:31:59 pv 2 power: 1433W
[site ] DEBUG 2025/06/17 11:31:59 pv power: 4494W
[site ] DEBUG 2025/06/17 11:31:59 site power: -208W
[lp-2 ] DEBUG 2025/06/17 11:31:59 charge voltages: [238 230 239]V
[lp-2 ] DEBUG 2025/06/17 11:31:59 detected connected phases: 3p
[lp-2 ] DEBUG 2025/06/17 11:31:59 detected active phases: 1p
[lp-2 ] DEBUG 2025/06/17 11:31:59 charge total import: 4851.263kWh
[lp-2 ] DEBUG 2025/06/17 11:31:59 charger status: C
[lp-2 ] ERROR 2025/06/17 11:31:59 vehicle soc: outdated
[lp-2 ] DEBUG 2025/06/17 11:31:59 pv charge current: 13.9A = 13A + 0.904A (-208W @ 1p)
[site ] DEBUG 2025/06/17 11:31:59 solar forecast: accumulated 8.804kWh, produced 24.057kWh, scale 2.733
[site ] DEBUG 2025/06/17 11:32:08 ----
[lp-1 ] DEBUG 2025/06/17 11:32:08 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:32:08 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:32:08 charge power: 5W
[lp-2 ] DEBUG 2025/06/17 11:32:08 charge power: 3027W
[lp-3 ] DEBUG 2025/06/17 11:32:08 charge currents: [0 0 0.0493]A
[lp-2 ] DEBUG 2025/06/17 11:32:08 charge currents: [0 13.2 0]A
[circuit-outdoor] DEBUG 2025/06/17 11:32:08 power: 3032.4W
[circuit-outdoor] DEBUG 2025/06/17 11:32:08 current: 13.2A
[circuit-main] DEBUG 2025/06/17 11:32:08 power: 3860W
[circuit-main] DEBUG 2025/06/17 11:32:08 current: 14.7A
[site ] DEBUG 2025/06/17 11:32:08 grid power: 3860W
[site ] DEBUG 2025/06/17 11:32:08 grid currents: [14.7 2.2 3.7]A
[site ] DEBUG 2025/06/17 11:32:08 pv 1 power: 3061W
[site ] DEBUG 2025/06/17 11:32:09 battery 1 power: -6321W
[site ] DEBUG 2025/06/17 11:32:09 battery 1 soc: 47%
[site ] DEBUG 2025/06/17 11:32:09 pv 2 power: 5831W
[site ] DEBUG 2025/06/17 11:32:09 pv power: 8892W
[site ] DEBUG 2025/06/17 11:32:09 site power: -2311W
[lp-3 ] DEBUG 2025/06/17 11:32:09 charge voltages: [242 234 243]V
[lp-3 ] DEBUG 2025/06/17 11:32:09 detected connected phases: 3p
[lp-3 ] DEBUG 2025/06/17 11:32:09 charge total import: 3018.109kWh
[lp-3 ] DEBUG 2025/06/17 11:32:09 charger status: B
[lp-3 ] DEBUG 2025/06/17 11:32:09 pv charge current: 3.35A = 0A + 3.35A (-2311W @ 3p)
[site ] DEBUG 2025/06/17 11:32:09 solar forecast: accumulated 8.820kWh, produced 24.066kWh, scale 2.729
[site ] DEBUG 2025/06/17 11:32:18 ----
[lp-1 ] DEBUG 2025/06/17 11:32:18 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:32:18 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:32:18 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:32:18 charge power: 3049W
[lp-2 ] DEBUG 2025/06/17 11:32:18 charge currents: [0 13.2 0]A
[lp-3 ] DEBUG 2025/06/17 11:32:18 charge currents: [0 0 0.0488]A
[circuit-outdoor] DEBUG 2025/06/17 11:32:18 power: 3054.2W
[circuit-outdoor] DEBUG 2025/06/17 11:32:18 current: 13.2A
[circuit-main] DEBUG 2025/06/17 11:32:18 power: -8412W
[circuit-main] DEBUG 2025/06/17 11:32:18 current: 16.9A
[site ] DEBUG 2025/06/17 11:32:18 grid power: -8412W
[site ] DEBUG 2025/06/17 11:32:18 grid currents: [5.1 16.9 15.5]A
[site ] DEBUG 2025/06/17 11:32:18 pv 1 power: 3061W
[site ] DEBUG 2025/06/17 11:32:19 battery 1 power: -6488W
[site ] DEBUG 2025/06/17 11:32:19 battery 1 soc: 47%
[site ] DEBUG 2025/06/17 11:32:19 pv 2 power: 5494W
[site ] DEBUG 2025/06/17 11:32:19 pv power: 8555W
[site ] DEBUG 2025/06/17 11:32:19 site power: -14750W
[lp-1 ] DEBUG 2025/06/17 11:32:19 charge total import: 0.000kWh
[lp-1 ] DEBUG 2025/06/17 11:32:19 charger status: A
[site ] DEBUG 2025/06/17 11:32:19 solar forecast: accumulated 8.836kWh, produced 24.074kWh, scale 2.725
[site ] DEBUG 2025/06/17 11:32:28 ----
[lp-1 ] DEBUG 2025/06/17 11:32:28 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:32:28 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:32:28 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:32:28 charge power: 3073W
[lp-3 ] DEBUG 2025/06/17 11:32:28 charge currents: [0 0 0.0493]A
[lp-2 ] DEBUG 2025/06/17 11:32:28 charge currents: [0 13.2 0]A
[circuit-outdoor] DEBUG 2025/06/17 11:32:28 power: 3078.6W
[circuit-outdoor] DEBUG 2025/06/17 11:32:28 current: 13.2A
[circuit-main] DEBUG 2025/06/17 11:32:28 power: -8733W
[circuit-main] DEBUG 2025/06/17 11:32:28 current: 17.2A
[site ] DEBUG 2025/06/17 11:32:28 grid power: -8733W
[site ] DEBUG 2025/06/17 11:32:28 grid currents: [5.4 17.2 15.8]A
[site ] DEBUG 2025/06/17 11:32:28 pv 1 power: 13192W
[site ] DEBUG 2025/06/17 11:32:29 battery 1 power: -6489W
[site ] DEBUG 2025/06/17 11:32:29 pv 2 power: 6196W
[site ] DEBUG 2025/06/17 11:32:29 battery 1 soc: 47%
[site ] DEBUG 2025/06/17 11:32:29 pv power: 19388W
[site ] DEBUG 2025/06/17 11:32:29 site power: -15072W
[lp-2 ] DEBUG 2025/06/17 11:32:29 charge voltages: [245 237 245]V
[lp-2 ] DEBUG 2025/06/17 11:32:29 detected connected phases: 3p
[lp-2 ] DEBUG 2025/06/17 11:32:29 detected active phases: 1p
[lp-2 ] DEBUG 2025/06/17 11:32:29 charge total import: 4851.289kWh
[lp-2 ] DEBUG 2025/06/17 11:32:29 charger status: C
[lp-2 ] ERROR 2025/06/17 11:32:29 vehicle soc: outdated
[lp-2 ] DEBUG 2025/06/17 11:32:29 pv charge current: 78.5A = 13A + 65.5A (-15072W @ 1p)
[lp-2 ] DEBUG 2025/06/17 11:32:29 set charge current limit: 16A
[site ] DEBUG 2025/06/17 11:32:29 solar forecast: accumulated 8.853kWh, produced 24.111kWh, scale 2.724
[site ] DEBUG 2025/06/17 11:32:38 ----
[lp-1 ] DEBUG 2025/06/17 11:32:38 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:32:38 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:32:38 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:32:38 charge power: 3745W
[lp-2 ] DEBUG 2025/06/17 11:32:38 charge currents: [0 16.2 0.0523]A
[lp-3 ] DEBUG 2025/06/17 11:32:38 charge currents: [0 0 0.0492]A
[circuit-outdoor] DEBUG 2025/06/17 11:32:38 power: 3750.9W
[circuit-outdoor] DEBUG 2025/06/17 11:32:38 current: 16.2A
[circuit-main] DEBUG 2025/06/17 11:32:38 power: -8014W
[circuit-main] DEBUG 2025/06/17 11:32:38 current: 17.2A
[site ] DEBUG 2025/06/17 11:32:38 grid power: -8014W
[site ] DEBUG 2025/06/17 11:32:38 grid currents: [4.4 17.2 15.8]A
[site ] DEBUG 2025/06/17 11:32:38 pv 1 power: 13192W
[site ] DEBUG 2025/06/17 11:32:39 battery 1 power: -6491W
[site ] DEBUG 2025/06/17 11:32:39 pv 2 power: 6147W
[site ] DEBUG 2025/06/17 11:32:39 battery 1 soc: 47%
[site ] DEBUG 2025/06/17 11:32:39 pv power: 19339W
[site ] DEBUG 2025/06/17 11:32:39 site power: -14355W
[lp-3 ] DEBUG 2025/06/17 11:32:39 charge voltages: [247 235 245]V
[lp-3 ] DEBUG 2025/06/17 11:32:39 detected connected phases: 3p
[lp-3 ] DEBUG 2025/06/17 11:32:39 charge total import: 3018.109kWh
[lp-3 ] DEBUG 2025/06/17 11:32:39 charger status: B
[lp-3 ] DEBUG 2025/06/17 11:32:39 pv charge current: 20.8A = 0A + 20.8A (-14355W @ 3p)
[lp-3 ] DEBUG 2025/06/17 11:32:39 site power -14355W <= 0W enable threshold
[lp-3 ] DEBUG 2025/06/17 11:32:39 pv enable timer start: 1m0s
[lp-3 ] DEBUG 2025/06/17 11:32:39 pv enable in 1m0s
[site ] DEBUG 2025/06/17 11:32:39 solar forecast: accumulated 8.869kWh, produced 24.148kWh, scale 2.723
[site ] DEBUG 2025/06/17 11:32:48 ----
[lp-1 ] DEBUG 2025/06/17 11:32:48 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:32:48 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:32:48 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:32:48 charge power: 3745W
[lp-2 ] DEBUG 2025/06/17 11:32:48 charge currents: [0 16.2 0.0531]A
[lp-3 ] DEBUG 2025/06/17 11:32:48 charge currents: [0 0 0.0495]A
[circuit-outdoor] DEBUG 2025/06/17 11:32:48 power: 3751.2W
[circuit-outdoor] DEBUG 2025/06/17 11:32:48 current: 16.3A
[circuit-main] DEBUG 2025/06/17 11:32:48 power: -7883W
[circuit-main] DEBUG 2025/06/17 11:32:48 current: 17.1A
[site ] DEBUG 2025/06/17 11:32:48 grid power: -7883W
[site ] DEBUG 2025/06/17 11:32:48 grid currents: [4.5 17.1 15.7]A
[site ] DEBUG 2025/06/17 11:32:48 pv 1 power: 13192W
[site ] DEBUG 2025/06/17 11:32:49 battery 1 power: -6493W
[site ] DEBUG 2025/06/17 11:32:49 pv 2 power: 6145W
[site ] DEBUG 2025/06/17 11:32:49 battery 1 soc: 47%
[site ] DEBUG 2025/06/17 11:32:49 pv power: 19337W
[site ] DEBUG 2025/06/17 11:32:49 site power: -14226W
[lp-1 ] DEBUG 2025/06/17 11:32:49 charge total import: 0.000kWh
[lp-1 ] DEBUG 2025/06/17 11:32:49 charger status: A
[site ] DEBUG 2025/06/17 11:32:49 solar forecast: accumulated 8.884kWh, produced 24.284kWh, scale 2.733
[site ] DEBUG 2025/06/17 11:32:58 ----
[lp-1 ] DEBUG 2025/06/17 11:32:58 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:32:58 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:32:58 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:32:58 charge power: 3739W
[lp-3 ] DEBUG 2025/06/17 11:32:58 charge currents: [0 0 0.0495]A
[lp-2 ] DEBUG 2025/06/17 11:32:58 charge currents: [0 16.2 0.0527]A
[circuit-outdoor] DEBUG 2025/06/17 11:32:58 power: 3744.6W
[circuit-outdoor] DEBUG 2025/06/17 11:32:58 current: 16.2A
[circuit-main] DEBUG 2025/06/17 11:32:59 power: -7723W
[circuit-main] DEBUG 2025/06/17 11:32:59 current: 17A
[site ] DEBUG 2025/06/17 11:32:59 grid power: -7723W
[site ] DEBUG 2025/06/17 11:32:59 grid currents: [4.4 17 15.3]A
[site ] DEBUG 2025/06/17 11:32:59 pv 1 power: 13432W
[site ] DEBUG 2025/06/17 11:32:59 battery 1 power: -6493W
[site ] DEBUG 2025/06/17 11:32:59 battery 1 soc: 47%
[site ] DEBUG 2025/06/17 11:32:59 pv 2 power: 6152W
[site ] DEBUG 2025/06/17 11:32:59 pv power: 19584W
[site ] DEBUG 2025/06/17 11:32:59 site power: -14066W
[lp-2 ] DEBUG 2025/06/17 11:32:59 charge voltages: [246 235 245]V
[lp-2 ] DEBUG 2025/06/17 11:32:59 detected connected phases: 3p
[lp-2 ] DEBUG 2025/06/17 11:32:59 detected active phases: 1p
[lp-2 ] DEBUG 2025/06/17 11:32:59 charge total import: 4851.320kWh
[lp-2 ] DEBUG 2025/06/17 11:32:59 charger status: C
[lp-2 ] ERROR 2025/06/17 11:32:59 vehicle soc: outdated
[lp-2 ] DEBUG 2025/06/17 11:32:59 pv charge current: 77.2A = 16A + 61.2A (-14066W @ 1p)
[site ] DEBUG 2025/06/17 11:32:59 solar forecast: accumulated 8.901kWh, produced 24.321kWh, scale 2.732
[site ] DEBUG 2025/06/17 11:33:08 ----
[lp-1 ] DEBUG 2025/06/17 11:33:08 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:33:08 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:33:08 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:33:08 charge power: 3743W
[lp-3 ] DEBUG 2025/06/17 11:33:08 charge currents: [0 0 0.0489]A
[lp-2 ] DEBUG 2025/06/17 11:33:08 charge currents: [0 16.2 0.0526]A
[circuit-outdoor] DEBUG 2025/06/17 11:33:08 power: 3748.8W
[circuit-outdoor] DEBUG 2025/06/17 11:33:08 current: 16.2A
[circuit-main] DEBUG 2025/06/17 11:33:08 power: -7793W
[circuit-main] DEBUG 2025/06/17 11:33:08 current: 17A
[site ] DEBUG 2025/06/17 11:33:08 grid power: -7793W
[site ] DEBUG 2025/06/17 11:33:08 grid currents: [4.5 17 15.4]A
[site ] DEBUG 2025/06/17 11:33:08 pv 1 power: 13432W
[site ] DEBUG 2025/06/17 11:33:09 battery 1 power: -6493W
[site ] DEBUG 2025/06/17 11:33:09 pv 2 power: 6162W
[site ] DEBUG 2025/06/17 11:33:09 battery 1 soc: 47%
[site ] DEBUG 2025/06/17 11:33:09 pv power: 19594W
[site ] DEBUG 2025/06/17 11:33:09 site power: -14136W
[lp-3 ] DEBUG 2025/06/17 11:33:09 charge voltages: [246 235 246]V
[lp-3 ] DEBUG 2025/06/17 11:33:09 detected connected phases: 3p
[lp-3 ] DEBUG 2025/06/17 11:33:09 charge total import: 3018.109kWh
[lp-3 ] DEBUG 2025/06/17 11:33:09 charger status: B
[lp-3 ] DEBUG 2025/06/17 11:33:09 pv charge current: 20.5A = 0A + 20.5A (-14136W @ 3p)
[lp-3 ] DEBUG 2025/06/17 11:33:09 site power -14136W <= 0W enable threshold
[lp-3 ] DEBUG 2025/06/17 11:33:09 pv enable in 30s
[lp-3 ] DEBUG 2025/06/17 11:33:09 pv enable timer remaining: 30s
[site ] DEBUG 2025/06/17 11:33:09 solar forecast: accumulated 8.917kWh, produced 24.359kWh, scale 2.732
[site ] DEBUG 2025/06/17 11:33:18 ----
[lp-1 ] DEBUG 2025/06/17 11:33:18 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:33:18 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:33:18 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:33:18 charge power: 3744W
[lp-2 ] DEBUG 2025/06/17 11:33:18 charge currents: [0 16.2 0.0525]A
[lp-3 ] DEBUG 2025/06/17 11:33:18 charge currents: [0 0 0.0496]A
[circuit-outdoor] DEBUG 2025/06/17 11:33:18 power: 3749.6W
[circuit-outdoor] DEBUG 2025/06/17 11:33:18 current: 16.2A
[circuit-main] DEBUG 2025/06/17 11:33:18 power: -7816W
[circuit-main] DEBUG 2025/06/17 11:33:18 current: 17.1A
[site ] DEBUG 2025/06/17 11:33:18 grid power: -7816W
[site ] DEBUG 2025/06/17 11:33:18 grid currents: [4.4 17.1 15.4]A
[site ] DEBUG 2025/06/17 11:33:18 pv 1 power: 13432W
[site ] DEBUG 2025/06/17 11:33:19 battery 1 power: -6490W
[site ] DEBUG 2025/06/17 11:33:19 pv 2 power: 6172W
[site ] DEBUG 2025/06/17 11:33:19 pv power: 19604W
[site ] DEBUG 2025/06/17 11:33:19 battery 1 soc: 47%
[site ] DEBUG 2025/06/17 11:33:19 site power: -14156W
[lp-1 ] DEBUG 2025/06/17 11:33:19 charge total import: 0.000kWh
[lp-1 ] DEBUG 2025/06/17 11:33:19 charger status: A
[site ] DEBUG 2025/06/17 11:33:19 solar forecast: accumulated 8.933kWh, produced 24.396kWh, scale 2.731
[site ] DEBUG 2025/06/17 11:33:28 ----
[lp-1 ] DEBUG 2025/06/17 11:33:28 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:33:28 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:33:28 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:33:28 charge power: 3741W
[lp-2 ] DEBUG 2025/06/17 11:33:28 charge currents: [0 16.2 0.0523]A
[lp-3 ] DEBUG 2025/06/17 11:33:28 charge currents: [0 0 0.0493]A
[circuit-outdoor] DEBUG 2025/06/17 11:33:28 power: 3746.9W
[circuit-outdoor] DEBUG 2025/06/17 11:33:28 current: 16.2A
[circuit-main] DEBUG 2025/06/17 11:33:28 power: -7856W
[circuit-main] DEBUG 2025/06/17 11:33:28 current: 17A
[site ] DEBUG 2025/06/17 11:33:28 grid power: -7856W
[site ] DEBUG 2025/06/17 11:33:28 grid currents: [4.4 17 15.6]A
[site ] DEBUG 2025/06/17 11:33:28 pv 1 power: 13448W
[site ] DEBUG 2025/06/17 11:33:29 battery 1 power: -6491W
[site ] DEBUG 2025/06/17 11:33:29 battery 1 soc: 47%
[site ] DEBUG 2025/06/17 11:33:29 pv 2 power: 6172W
[site ] DEBUG 2025/06/17 11:33:29 pv power: 19620W
[site ] DEBUG 2025/06/17 11:33:29 site power: -14197W
[lp-2 ] DEBUG 2025/06/17 11:33:29 charge voltages: [247 235 246]V
[lp-2 ] DEBUG 2025/06/17 11:33:29 detected connected phases: 3p
[lp-2 ] DEBUG 2025/06/17 11:33:29 detected active phases: 1p
[lp-2 ] DEBUG 2025/06/17 11:33:29 charge total import: 4851.351kWh
[lp-2 ] DEBUG 2025/06/17 11:33:29 charger status: C
[lp-2 ] ERROR 2025/06/17 11:33:29 vehicle soc: outdated
[lp-2 ] DEBUG 2025/06/17 11:33:29 pv charge current: 77.7A = 16A + 61.7A (-14197W @ 1p)
[site ] DEBUG 2025/06/17 11:33:29 solar forecast: accumulated 8.950kWh, produced 24.433kWh, scale 2.730
[site ] DEBUG 2025/06/17 11:33:38 ----
[lp-1 ] DEBUG 2025/06/17 11:33:38 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:33:38 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:33:38 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:33:38 charge power: 3744W
[lp-2 ] DEBUG 2025/06/17 11:33:38 charge currents: [0 16.2 0.0523]A
[lp-3 ] DEBUG 2025/06/17 11:33:38 charge currents: [0 0 0.0492]A
[circuit-outdoor] DEBUG 2025/06/17 11:33:38 power: 3749.9W
[circuit-outdoor] DEBUG 2025/06/17 11:33:38 current: 16.2A
[circuit-main] DEBUG 2025/06/17 11:33:38 power: -7859W
[circuit-main] DEBUG 2025/06/17 11:33:38 current: 17A
[site ] DEBUG 2025/06/17 11:33:38 grid power: -7859W
[site ] DEBUG 2025/06/17 11:33:38 grid currents: [4.4 17 15.6]A
[site ] DEBUG 2025/06/17 11:33:38 pv 1 power: 13448W
[site ] DEBUG 2025/06/17 11:33:39 battery 1 power: -6491W
[site ] DEBUG 2025/06/17 11:33:39 battery 1 soc: 47%
[site ] DEBUG 2025/06/17 11:33:39 pv 2 power: 6174W
[site ] DEBUG 2025/06/17 11:33:39 pv power: 19622W
[site ] DEBUG 2025/06/17 11:33:39 site power: -14200W
[lp-3 ] DEBUG 2025/06/17 11:33:39 charge voltages: [247 235 246]V
[lp-3 ] DEBUG 2025/06/17 11:33:39 detected connected phases: 3p
[lp-3 ] DEBUG 2025/06/17 11:33:39 charge total import: 3018.109kWh
[lp-3 ] DEBUG 2025/06/17 11:33:39 charger status: B
[lp-3 ] DEBUG 2025/06/17 11:33:39 pv charge current: 20.6A = 0A + 20.6A (-14200W @ 3p)
[lp-3 ] DEBUG 2025/06/17 11:33:39 site power -14200W <= 0W enable threshold
[lp-3 ] DEBUG 2025/06/17 11:33:39 pv enable in 0s
[lp-3 ] DEBUG 2025/06/17 11:33:39 pv enable timer remaining: 0s
[site ] DEBUG 2025/06/17 11:33:39 solar forecast: accumulated 8.966kWh, produced 24.571kWh, scale 2.740
[site ] DEBUG 2025/06/17 11:33:48 ----
[lp-1 ] DEBUG 2025/06/17 11:33:48 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:33:48 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:33:48 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:33:48 charge power: 3745W
[lp-3 ] DEBUG 2025/06/17 11:33:48 charge currents: [0 0 0.0491]A
[lp-2 ] DEBUG 2025/06/17 11:33:48 charge currents: [0 16.2 0.053]A
[circuit-outdoor] DEBUG 2025/06/17 11:33:48 power: 3750.8W
[circuit-outdoor] DEBUG 2025/06/17 11:33:48 current: 16.2A
[circuit-main] DEBUG 2025/06/17 11:33:48 power: -7845W
[circuit-main] DEBUG 2025/06/17 11:33:48 current: 17.1A
[site ] DEBUG 2025/06/17 11:33:48 grid power: -7845W
[site ] DEBUG 2025/06/17 11:33:48 grid currents: [4.5 17.1 15.5]A
[site ] DEBUG 2025/06/17 11:33:48 pv 1 power: 13448W
[site ] DEBUG 2025/06/17 11:33:49 battery 1 power: -6488W
[site ] DEBUG 2025/06/17 11:33:49 pv 2 power: 6178W
[site ] DEBUG 2025/06/17 11:33:49 battery 1 soc: 47%
[site ] DEBUG 2025/06/17 11:33:49 pv power: 19626W
[site ] DEBUG 2025/06/17 11:33:49 site power: -14183W
[lp-1 ] DEBUG 2025/06/17 11:33:49 charge total import: 0.000kWh
[lp-1 ] DEBUG 2025/06/17 11:33:49 charger status: A
[site ] DEBUG 2025/06/17 11:33:49 solar forecast: accumulated 8.982kWh, produced 24.608kWh, scale 2.740
[site ] DEBUG 2025/06/17 11:33:58 ----
[lp-1 ] DEBUG 2025/06/17 11:33:58 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:33:58 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:33:58 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:33:58 charge power: 3742W
[lp-3 ] DEBUG 2025/06/17 11:33:58 charge currents: [0 0 0.049]A
[lp-2 ] DEBUG 2025/06/17 11:33:58 charge currents: [0 16.2 0.0526]A
[circuit-outdoor] DEBUG 2025/06/17 11:33:58 power: 3748.1W
[circuit-outdoor] DEBUG 2025/06/17 11:33:58 current: 16.2A
[circuit-main] DEBUG 2025/06/17 11:33:58 power: -7800W
[circuit-main] DEBUG 2025/06/17 11:33:58 current: 17A
[site ] DEBUG 2025/06/17 11:33:58 grid power: -7800W
[site ] DEBUG 2025/06/17 11:33:58 grid currents: [4.4 17 15.5]A
[site ] DEBUG 2025/06/17 11:33:58 pv 1 power: 13407W
[site ] DEBUG 2025/06/17 11:33:59 battery 1 power: -6487W
[site ] DEBUG 2025/06/17 11:33:59 pv 2 power: 6167W
[site ] DEBUG 2025/06/17 11:33:59 battery 1 soc: 47%
[site ] DEBUG 2025/06/17 11:33:59 pv power: 19574W
[site ] DEBUG 2025/06/17 11:33:59 site power: -14137W
[lp-2 ] DEBUG 2025/06/17 11:33:59 charge voltages: [247 235 246]V
[lp-2 ] DEBUG 2025/06/17 11:33:59 detected connected phases: 3p
[lp-2 ] DEBUG 2025/06/17 11:33:59 detected active phases: 1p
[lp-2 ] DEBUG 2025/06/17 11:33:59 charge total import: 4851.382kWh
[lp-2 ] DEBUG 2025/06/17 11:33:59 charger status: C
[lp-2 ] ERROR 2025/06/17 11:33:59 vehicle soc: outdated
[lp-2 ] DEBUG 2025/06/17 11:33:59 pv charge current: 77.5A = 16A + 61.5A (-14137W @ 1p)
[site ] DEBUG 2025/06/17 11:33:59 solar forecast: accumulated 8.999kWh, produced 24.645kWh, scale 2.739
[site ] DEBUG 2025/06/17 11:34:08 ----
[lp-1 ] DEBUG 2025/06/17 11:34:08 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:34:08 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:34:08 charge power: 6W
[lp-2 ] DEBUG 2025/06/17 11:34:08 charge power: 3744W
[lp-3 ] DEBUG 2025/06/17 11:34:08 charge currents: [0 0 0.0494]A
[lp-2 ] DEBUG 2025/06/17 11:34:08 charge currents: [0 16.2 0.0529]A
[circuit-outdoor] DEBUG 2025/06/17 11:34:08 power: 3750W
[circuit-outdoor] DEBUG 2025/06/17 11:34:08 current: 16.2A
[circuit-main] DEBUG 2025/06/17 11:34:08 power: -7539W
[circuit-main] DEBUG 2025/06/17 11:34:08 current: 16.3A
[site ] DEBUG 2025/06/17 11:34:08 grid power: -7539W
[site ] DEBUG 2025/06/17 11:34:08 grid currents: [4.4 16.3 15]A
[site ] DEBUG 2025/06/17 11:34:08 pv 1 power: 13407W
[site ] DEBUG 2025/06/17 11:34:09 battery 1 power: -6489W
[site ] DEBUG 2025/06/17 11:34:09 pv 2 power: 6164W
[site ] DEBUG 2025/06/17 11:34:09 battery 1 soc: 47%
[site ] DEBUG 2025/06/17 11:34:09 pv power: 19571W
[site ] DEBUG 2025/06/17 11:34:09 site power: -13878W
[lp-3 ] DEBUG 2025/06/17 11:34:09 charge voltages: [247 236 246]V
[lp-3 ] DEBUG 2025/06/17 11:34:09 detected connected phases: 3p
[lp-3 ] DEBUG 2025/06/17 11:34:09 charge total import: 3018.109kWh
[lp-3 ] DEBUG 2025/06/17 11:34:09 charger status: B
[lp-3 ] DEBUG 2025/06/17 11:34:09 pv charge current: 20.1A = 0A + 20.1A (-13878W @ 3p)
[lp-3 ] DEBUG 2025/06/17 11:34:09 site power -13878W <= 0W enable threshold
[lp-3 ] DEBUG 2025/06/17 11:34:09 pv enable in 0s
[lp-3 ] DEBUG 2025/06/17 11:34:09 pv enable timer elapsed
[lp-3 ] DEBUG 2025/06/17 11:34:09 pv timer reset
[lp-3 ] DEBUG 2025/06/17 11:34:09 pv timer inactive
[lp-3 ] DEBUG 2025/06/17 11:34:09 set charge current limit: 6A
[lp-3 ] DEBUG 2025/06/17 11:34:09 charger enable
[lp-3 ] DEBUG 2025/06/17 11:34:09 wake-up timer: start
[site ] DEBUG 2025/06/17 11:34:09 solar forecast: accumulated 9.015kWh, produced 24.682kWh, scale 2.738
[site ] DEBUG 2025/06/17 11:34:18 ----
[lp-1 ] DEBUG 2025/06/17 11:34:18 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:34:18 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:34:18 charge power: 9W
[lp-2 ] DEBUG 2025/06/17 11:34:18 charge power: 3743W
[lp-2 ] DEBUG 2025/06/17 11:34:18 charge currents: [0 16.1 0.0527]A
[lp-3 ] DEBUG 2025/06/17 11:34:18 charge currents: [0 0 0.415]A
[circuit-outdoor] DEBUG 2025/06/17 11:34:18 power: 3752.3W
[circuit-outdoor] DEBUG 2025/06/17 11:34:18 current: 16.6A
[circuit-main] DEBUG 2025/06/17 11:34:18 power: -7589W
[circuit-main] DEBUG 2025/06/17 11:34:18 current: 16.4A
[site ] DEBUG 2025/06/17 11:34:18 grid power: -7589W
[site ] DEBUG 2025/06/17 11:34:18 pv 1 power: 13407W
[site ] DEBUG 2025/06/17 11:34:18 grid currents: [4.6 16.4 15.3]A
[site ] DEBUG 2025/06/17 11:34:19 battery 1 power: -6486W
[site ] DEBUG 2025/06/17 11:34:19 battery 1 soc: 48%
[site ] DEBUG 2025/06/17 11:34:19 pv 2 power: 6187W
[site ] DEBUG 2025/06/17 11:34:19 pv power: 19594W
[site ] DEBUG 2025/06/17 11:34:19 site power: -13925W
[lp-1 ] DEBUG 2025/06/17 11:34:19 charge total import: 0.000kWh
[lp-1 ] DEBUG 2025/06/17 11:34:19 charger status: A
[site ] DEBUG 2025/06/17 11:34:19 solar forecast: accumulated 9.031kWh, produced 24.720kWh, scale 2.737
[site ] DEBUG 2025/06/17 11:34:28 ----
[lp-1 ] DEBUG 2025/06/17 11:34:28 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:34:28 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:34:28 charge power: 775W
[lp-2 ] DEBUG 2025/06/17 11:34:28 charge power: 3743W
[lp-3 ] DEBUG 2025/06/17 11:34:28 charge currents: [0.649 0 3.27]A
[lp-2 ] DEBUG 2025/06/17 11:34:28 charge currents: [0 16.1 0.0526]A
[circuit-outdoor] DEBUG 2025/06/17 11:34:28 power: 4518.2W
[circuit-outdoor] DEBUG 2025/06/17 11:34:28 current: 19.4A
[circuit-main] DEBUG 2025/06/17 11:34:28 power: -6981W
[circuit-main] DEBUG 2025/06/17 11:34:28 current: 15.3A
[site ] DEBUG 2025/06/17 11:34:28 grid power: -6981W
[site ] DEBUG 2025/06/17 11:34:28 grid currents: [4.7 13.9 15.3]A
[site ] DEBUG 2025/06/17 11:34:28 pv 1 power: 13407W
[site ] DEBUG 2025/06/17 11:34:29 battery 1 power: -6487W
[site ] DEBUG 2025/06/17 11:34:29 battery 1 soc: 48%
[site ] DEBUG 2025/06/17 11:34:29 pv 2 power: 6166W
[site ] DEBUG 2025/06/17 11:34:29 pv power: 19573W
[site ] DEBUG 2025/06/17 11:34:29 site power: -13318W
[lp-2 ] DEBUG 2025/06/17 11:34:29 charge voltages: [247 236 245]V
[lp-2 ] DEBUG 2025/06/17 11:34:29 detected connected phases: 3p
[lp-2 ] DEBUG 2025/06/17 11:34:29 detected active phases: 1p
[lp-2 ] DEBUG 2025/06/17 11:34:29 charge total import: 4851.414kWh
[lp-2 ] DEBUG 2025/06/17 11:34:29 charger status: C
[lp-2 ] ERROR 2025/06/17 11:34:29 vehicle soc: outdated
[lp-2 ] DEBUG 2025/06/17 11:34:29 pv charge current: 73.9A = 16A + 57.9A (-13318W @ 1p)
[site ] DEBUG 2025/06/17 11:34:29 solar forecast: accumulated 9.048kWh, produced 24.757kWh, scale 2.736
[site ] DEBUG 2025/06/17 11:34:38 ----
[lp-1 ] DEBUG 2025/06/17 11:34:38 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:34:38 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:34:38 charge power: 4407W
[lp-2 ] DEBUG 2025/06/17 11:34:38 charge power: 3744W
[lp-2 ] DEBUG 2025/06/17 11:34:38 charge currents: [0 16.3 0.0535]A
[lp-3 ] DEBUG 2025/06/17 11:34:38 charge currents: [6.12 6.1 6.17]A
[circuit-outdoor] DEBUG 2025/06/17 11:34:38 power: 8151.2W
[circuit-outdoor] DEBUG 2025/06/17 11:34:38 current: 22.5A
[circuit-main] DEBUG 2025/06/17 11:34:38 power: -4816W
[circuit-main] DEBUG 2025/06/17 11:34:38 current: 10.8A
[site ] DEBUG 2025/06/17 11:34:38 grid power: -4816W
[site ] DEBUG 2025/06/17 11:34:38 grid currents: [4.5 10.8 9.8]A
[site ] DEBUG 2025/06/17 11:34:38 pv 1 power: 13438W
[site ] DEBUG 2025/06/17 11:34:39 battery 1 power: -6488W
[site ] DEBUG 2025/06/17 11:34:39 pv 2 power: 6168W
[site ] DEBUG 2025/06/17 11:34:39 battery 1 soc: 48%
[site ] DEBUG 2025/06/17 11:34:39 pv power: 19606W
[site ] DEBUG 2025/06/17 11:34:39 site power: -11154W
[lp-3 ] DEBUG 2025/06/17 11:34:39 charge voltages: [245 233 244]V
[lp-3 ] DEBUG 2025/06/17 11:34:39 detected connected phases: 3p
[lp-3 ] DEBUG 2025/06/17 11:34:39 charge total import: 3018.120kWh
[lp-3 ] DEBUG 2025/06/17 11:34:39 charger status: C
[lp-3 ] DEBUG 2025/06/17 11:34:39 charge start energy: 3018.120kWh
[lp-3 ] INFO 2025/06/17 11:34:39 start charging ->
[lp-3 ] DEBUG 2025/06/17 11:34:39 wake-up timer: stop
[lp-3 ] DEBUG 2025/06/17 11:34:39 soc estimated: 38.23% (vehicle: 38.00%)
[lp-3 ] DEBUG 2025/06/17 11:34:39 vehicle soc: 38%
[lp-3 ] DEBUG 2025/06/17 11:34:39 vehicle soc limit: 100%
[lp-3 ] DEBUG 2025/06/17 11:34:39 vehicle range: 152km
[lp-3 ] DEBUG 2025/06/17 11:34:39 pv charge current: 22.2A = 6A + 16.2A (-11154W @ 3p)
[lp-3 ] DEBUG 2025/06/17 11:34:39 set charge current limit: 16A
[site ] DEBUG 2025/06/17 11:34:39 solar forecast: accumulated 9.065kWh, produced 24.894kWh, scale 2.746
[site ] DEBUG 2025/06/17 11:34:48 ----
[lp-1 ] DEBUG 2025/06/17 11:34:48 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:34:48 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:34:48 charge power: 8378W
[lp-2 ] DEBUG 2025/06/17 11:34:48 charge power: 3714W
[lp-3 ] DEBUG 2025/06/17 11:34:48 charge currents: [12.3 13.3 13.3]A
[lp-2 ] DEBUG 2025/06/17 11:34:48 charge currents: [0 16.3 0.0538]A
[circuit-outdoor] DEBUG 2025/06/17 11:34:48 power: 12092W
[circuit-outdoor] DEBUG 2025/06/17 11:34:48 current: 29.6A
[circuit-main] DEBUG 2025/06/17 11:34:49 power: -868W
[circuit-main] DEBUG 2025/06/17 11:34:49 current: 10.2A
[site ] DEBUG 2025/06/17 11:34:49 grid power: -868W
[site ] DEBUG 2025/06/17 11:34:49 grid currents: [10.2 7.4 6.7]A
[site ] DEBUG 2025/06/17 11:34:49 pv 1 power: 13438W
[site ] DEBUG 2025/06/17 11:34:49 battery 1 power: -6492W
[site ] DEBUG 2025/06/17 11:34:49 pv 2 power: 6184W
[site ] DEBUG 2025/06/17 11:34:49 pv power: 19622W
[site ] DEBUG 2025/06/17 11:34:49 battery 1 soc: 48%
[site ] DEBUG 2025/06/17 11:34:49 site power: -7210W
[lp-1 ] DEBUG 2025/06/17 11:34:49 charge total import: 0.000kWh
[lp-1 ] DEBUG 2025/06/17 11:34:49 charger status: A
[site ] DEBUG 2025/06/17 11:34:49 solar forecast: accumulated 9.081kWh, produced 24.932kWh, scale 2.746
[site ] DEBUG 2025/06/17 11:34:58 ----
[lp-1 ] DEBUG 2025/06/17 11:34:58 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:34:58 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:34:58 charge power: 11349W
[lp-2 ] DEBUG 2025/06/17 11:34:58 charge power: 3716W
[lp-3 ] DEBUG 2025/06/17 11:34:58 charge currents: [15.9 15.9 15.9]A
[lp-2 ] DEBUG 2025/06/17 11:34:58 charge currents: [0 16.4 0.0533]A
[circuit-outdoor] DEBUG 2025/06/17 11:34:58 power: 15065W
[circuit-outdoor] DEBUG 2025/06/17 11:34:58 current: 32.3A
[circuit-main] DEBUG 2025/06/17 11:34:58 power: 3784W
[circuit-main] DEBUG 2025/06/17 11:34:58 current: 16.2A
[main ] DEBUG 2025/06/17 11:34:58 lp Einfahrt at prio 10 gets additional 11349W from Strasse at prio 8, total 11349W
[site ] DEBUG 2025/06/17 11:34:58 grid power: 3784W
[site ] DEBUG 2025/06/17 11:34:58 grid currents: [16.2 2.7 3.5]A
[site ] DEBUG 2025/06/17 11:34:58 pv 1 power: 13438W
[site ] DEBUG 2025/06/17 11:34:59 battery 1 power: -6491W
[site ] DEBUG 2025/06/17 11:34:59 pv 2 power: 6225W
[site ] DEBUG 2025/06/17 11:34:59 pv power: 19663W
[site ] DEBUG 2025/06/17 11:34:59 battery 1 soc: 48%
[site ] DEBUG 2025/06/17 11:34:59 site power: -13906W (including 11349W prioritized power)
[lp-2 ] DEBUG 2025/06/17 11:34:59 charge voltages: [242 231 242]V
[lp-2 ] DEBUG 2025/06/17 11:34:59 detected connected phases: 3p
[lp-2 ] DEBUG 2025/06/17 11:34:59 detected active phases: 1p
[lp-2 ] DEBUG 2025/06/17 11:34:59 charge total import: 4851.445kWh
[lp-2 ] DEBUG 2025/06/17 11:34:59 charger status: C
[lp-2 ] ERROR 2025/06/17 11:34:59 vehicle soc: outdated
[lp-2 ] DEBUG 2025/06/17 11:34:59 pv charge current: 76.5A = 16A + 60.5A (-13906W @ 1p)
[site ] DEBUG 2025/06/17 11:34:59 solar forecast: accumulated 9.097kWh, produced 24.969kWh, scale 2.745
[site ] DEBUG 2025/06/17 11:35:08 ----
[lp-1 ] DEBUG 2025/06/17 11:35:08 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:35:08 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:35:08 charge power: 11380W
[lp-2 ] DEBUG 2025/06/17 11:35:08 charge power: 3706W
[lp-3 ] DEBUG 2025/06/17 11:35:08 charge currents: [15.9 16 16]A
[lp-2 ] DEBUG 2025/06/17 11:35:08 charge currents: [0 16.3 0.0538]A
[circuit-outdoor] DEBUG 2025/06/17 11:35:08 power: 15086W
[circuit-outdoor] DEBUG 2025/06/17 11:35:08 current: 32.2A
[circuit-main] DEBUG 2025/06/17 11:35:08 power: 3735W
[circuit-main] DEBUG 2025/06/17 11:35:08 current: 16.2A
[site ] DEBUG 2025/06/17 11:35:08 grid power: 3735W
[site ] DEBUG 2025/06/17 11:35:08 grid currents: [16.2 2.8 3.4]A
[site ] DEBUG 2025/06/17 11:35:08 pv 1 power: 13464W
[site ] DEBUG 2025/06/17 11:35:09 battery 1 power: -6489W
[site ] DEBUG 2025/06/17 11:35:09 battery 1 soc: 48%
[site ] DEBUG 2025/06/17 11:35:09 pv 2 power: 6222W
[site ] DEBUG 2025/06/17 11:35:09 pv power: 19686W
[site ] DEBUG 2025/06/17 11:35:09 site power: -2604W
[lp-3 ] DEBUG 2025/06/17 11:35:09 charge voltages: [241 231 242]V
[lp-3 ] DEBUG 2025/06/17 11:35:09 detected connected phases: 3p
[lp-3 ] DEBUG 2025/06/17 11:35:09 detected active phases: 3p
[lp-3 ] DEBUG 2025/06/17 11:35:09 charge total import: 3018.202kWh
[lp-3 ] DEBUG 2025/06/17 11:35:09 charger status: C
[lp-3 ] DEBUG 2025/06/17 11:35:09 soc estimated: 38.37% (vehicle: 38.00%)
[lp-3 ] DEBUG 2025/06/17 11:35:09 vehicle soc: 38%
[lp-3 ] DEBUG 2025/06/17 11:35:09 vehicle soc limit: 100%
[lp-3 ] DEBUG 2025/06/17 11:35:09 vehicle range: 152km
[lp-3 ] DEBUG 2025/06/17 11:35:09 pv charge current: 19.8A = 16A + 3.77A (-2604W @ 3p)
[site ] DEBUG 2025/06/17 11:35:09 solar forecast: accumulated 9.114kWh, produced 25.006kWh, scale 2.744
[site ] DEBUG 2025/06/17 11:35:18 ----
[lp-1 ] DEBUG 2025/06/17 11:35:18 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:35:18 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:35:18 charge power: 11380W
[lp-2 ] DEBUG 2025/06/17 11:35:18 charge power: 3706W
[lp-3 ] DEBUG 2025/06/17 11:35:18 charge currents: [15.9 16 16]A
[lp-2 ] DEBUG 2025/06/17 11:35:18 charge currents: [0 16.3 0.0539]A
[circuit-outdoor] DEBUG 2025/06/17 11:35:18 power: 15086W
[circuit-outdoor] DEBUG 2025/06/17 11:35:18 current: 32.3A
[circuit-main] DEBUG 2025/06/17 11:35:18 power: 3726W
[circuit-main] DEBUG 2025/06/17 11:35:18 current: 16.1A
[site ] DEBUG 2025/06/17 11:35:18 grid power: 3726W
[site ] DEBUG 2025/06/17 11:35:18 grid currents: [16.1 2.9 3.3]A
[site ] DEBUG 2025/06/17 11:35:18 pv 1 power: 13464W
[site ] DEBUG 2025/06/17 11:35:19 battery 1 power: -6494W
[site ] DEBUG 2025/06/17 11:35:19 battery 1 soc: 48%
[site ] DEBUG 2025/06/17 11:35:19 pv 2 power: 6236W
[site ] DEBUG 2025/06/17 11:35:19 pv power: 19700W
[site ] DEBUG 2025/06/17 11:35:19 site power: -2618W
[lp-1 ] DEBUG 2025/06/17 11:35:19 charge total import: 0.000kWh
[lp-1 ] DEBUG 2025/06/17 11:35:19 charger status: A
[site ] DEBUG 2025/06/17 11:35:19 solar forecast: accumulated 9.130kWh, produced 25.044kWh, scale 2.743
[site ] DEBUG 2025/06/17 11:35:28 ----
[lp-1 ] DEBUG 2025/06/17 11:35:28 charge power: 0W
[lp-1 ] DEBUG 2025/06/17 11:35:28 charge currents: [0 0 0]A
[lp-3 ] DEBUG 2025/06/17 11:35:28 charge power: 11404W
What type of operating system or environment does evcc run on?
Docker container
External automation
- I have made sure that no external automation like HomeAssistant or Node-RED is active or accessing any of the mentioned devices when this issue occurs.
Nightly build
- I have verified that the issue is reproducible with the latest nightly build
Version
0.204.2