Firmware 4.0 Disconnect Stream Using S63=2 for DTR Function #143
Replies: 1 comment
-
So, version 3.7.1 of the firmware is still available in its own branch, and is recommended for the ESP8266. If you intend to remain with 4.0, then yes, the S63 register is the one to go. It does save with your configuration with AT&W though, so you only have to set it once. |
Beta Was this translation helpful? Give feedback.
0 replies
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Uh oh!
There was an error while loading. Please reload this page.
Uh oh!
There was an error while loading. Please reload this page.
-
@bozimmerman Since 1986 my BBS used drop of DTR line to disconnect a caller. This worked fine on firmware versions PRIOR to 4.0
I did a lot of checking on 4.0 to find there is a new S63 register which defaults to 0 but ensures the DTR disconnect when set to 2. I'm wondering if this is now the only way to do so, and whether it will negatively affect anything else.