Authors: Takanori Ishikawa ; Yasuhide Hyodo ; Ken Miyashita ; Kazunari Yoshifuji ; Yota Komoriya and Yutaka Imai

Affiliation: Sony Corporation, Japan

Keyword(s): PPG Sensor, Motion Artifact Cancellation Framework, Heart Rate Variability, Daily Activity, Ambulatory.

Abstract: A wristband-type PPG heart rate sensor capable of overcoming motion artifacts in daily activity and detecting heart rate variability has been developed together with a motion artifact cancellation framework. In this work, a motion artifact model in daily life was derived and motion artifacts caused by activity of arm, finger, and wrist were cancelled significantly. Highly reliable instant heart rate detection with high noise-resistance was achieved from noise-reduced pulse signals based on peak-detection and autocorrelation methods. The wristband-type PPG heart rate sensor with our motion artifact cancellation framework was compared with ECG instant heart rate measurement in both laboratory and office environments. In a laboratory environment, mean reliability (percentage of time within 10% error relative to ECG instant heart rate) was 86.5% and the one-day pulse-accuracy achievement rate based on time use data of body motions in daily life was 88.1% or approximately 21 hours. Our de vice and motion artifact cancellation framework enable continuous heart rate variability monitoring in daily life and could be applied to heart rate variability analysis and emotion recognition. (More)

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 79.170.44.78

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Ishikawa, T. ; Hyodo, Y. ; Miyashita, K. ; Yoshifuji, K. ; Komoriya, Y. and Imai, Y. (2017). Wearable Motion Tolerant PPG Sensor for Instant Heart Rate in Daily Activity. In Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2017) - BIOSIGNALS; ISBN 978-989-758-212-7; ISSN 2184-4305, SciTePress, pages 126-133. DOI: 10.5220/0006109901260133

@conference{biosignals17,
author={Takanori Ishikawa and Yasuhide Hyodo and Ken Miyashita and Kazunari Yoshifuji and Yota Komoriya and Yutaka Imai},
title={Wearable Motion Tolerant PPG Sensor for Instant Heart Rate in Daily Activity},
booktitle={Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2017) - BIOSIGNALS},
year={2017},
pages={126-133},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0006109901260133},
isbn={978-989-758-212-7},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2017) - BIOSIGNALS
TI - Wearable Motion Tolerant PPG Sensor for Instant Heart Rate in Daily Activity
SN - 978-989-758-212-7
IS - 2184-4305
AU - Ishikawa, T.
AU - Hyodo, Y.
AU - Miyashita, K.
AU - Yoshifuji, K.
AU - Komoriya, Y.
AU - Imai, Y.
PY - 2017
SP - 126
EP - 133
DO - 10.5220/0006109901260133
PB - SciTePress