[go: up one dir, main page]
More Web Proxy on the site http://driver.im/
Next Article in Journal
A Canopy Density Model for Planar Orchard Target Detection Based on Ultrasonic Sensors
Next Article in Special Issue
Enhancement of Fluorescence-Based Sandwich Immunoassay Using Multilayered Microplates Modified with Plasma-Polymerized Films
Previous Article in Journal
Organophosphorous Pesticide Detection in Olive Oil by Using a Miniaturized, Easy-to-Use, and Cost-Effective Biosensor Combined with QuEChERS for Sample Clean-Up
Previous Article in Special Issue
Visualization of Fluoride Ions In Vivo Using a Gadolinium(III)-Coumarin Complex-Based Fluorescence/MRI Dual-Modal Probe
You seem to have javascript disabled. Please note that many of the page functionalities won't work as expected without javascript enabled.
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

A Cu2+-Selective Probe Based on Phenanthro-Imidazole Derivative

1
Chemical Engineering College, Qinghai University, Xining 810016, China
2
Qinghai Heavy Industry Vocational School, Xining 810101, China
3
Department of Materials Science and Engineering, University of Utah, Salt Lake City, UT 84112, USA
*
Authors to whom correspondence should be addressed.
These two authors contributed equally.
Sensors 2017, 17(1), 35; https://doi.org/10.3390/s17010035
Submission received: 21 October 2016 / Revised: 20 December 2016 / Accepted: 21 December 2016 / Published: 24 December 2016
(This article belongs to the Special Issue Colorimetric and Fluorescent Sensor)

Abstract

:
A novel fluorescent Probe 1, based on phenanthro-imidazole has been developed as an efficient chemosensor for the trace detection of copper ions (Cu2+). Probe 1 demonstrated sensitive fluorescence quenching upon binding with Cu2+ through 1:1 stoichiometric chelation. The detection limit for Cu2+ ions was projected through linear quenching fitting to be as low as 2.77 × 10−8 M (or 1.77 ppb). The sensing response was highly selective towards Cu2+ with minimal influence from other common metal ions, facilitating the practical application of Probe 1 in trace detection.

1. Introduction

Copper (Cu2+), the third most abundant transition metal ion after Fe2+ and Zn2+ in the human body, plays a critical role in various fundamental physiological processes, such as those involving mitochondrial, cytosolic and vesicular oxygen-processing enzymes, which need copper as a redox cofactor [1,2]. Therefore, it is of great importance to develop simple, rapid and precise sensor methods to detect and monitor the concentration of Cu2+. Currently, there are many analytical methods for detecting Cu2+, such as atomic absorption spectroscopy (AAS) [3], inductive coupled plasma-mass spectroscopy (ICP-MS) [4], and fluorescence and surface plasmon resonance sensor methods [5,6,7]. Among these methods, fluorescence sensing remains one of the most promising approaches due to its high sensitivity, rapid response, and high selectivity through molecular binding design, as well as its simple solution assay processing [8,9,10,11,12]. Particularly, fluorescence sensors are suited for being embedded within tissues or cells for in situ imaging of Cu2+ ions and the associated physiological processes.
To date, numerous studies have been performed on the rational design of fluorescent chemosensors (probes) for the detection of ions and neutral analytes [13,14,15,16,17,18,19]. Many of these sensors have been proven effective for detecting Cu2+ ions [20,21,22,23,24,25,26,27,28], though in most of the cases the detection limit is not low enough to afford Cu2+ monitoring in blood and other biological systems. Moreover, the synthesis of fluorescence sensors often requires multiple step reactions, thus making the final product higher in cost, limiting the commercial use. To overcome these problems, we report herein on a novel fluorescent Probe 1, which responds to the presence of Cu2+ with sensitive fluorescence quenching. Probe 1 is composed of a 1H-phenanthro [9, 10-d] imidazole moiety connected to a N,N-bis(pyridin-2-ylmethyl) benzeneamine unit, and can be synthesized in just one step. The selection of 1H-phenanthro [9, 10-d] imidazole dye is based on the consideration that it can function both as a fluorophore and an electron donor in an electron charge transfer (CT) system [12]. The N,N-bis(pyridin-2-ylmethyl) benzenamine moiety was chosen as the binding group for Cu2+ ions [29], and it can then become an efficient electron acceptor, resulting in fluorescence quenching through the CT process. Our study showed that the fluorescence quenching of Probe 1 was fast and highly selective towards Cu2+ over other common metal ions, implying great potential for using this probe for quick, trace-level detection of Cu2+ ions.

2. Experimental

2.1. Materials and Methods

All chemicals and reagents except for Probe 1 were used as purchased without further purification. For the synthesis of Probe 1 300–400 mesh silica gel was used for column chromatography for the compound purification. 1H NMR and 13C NMR spectra were recorded on an Agilent DD2 NMR spectrometer (Agilent Technologies, Santa Clara, CA, USA) at 600 MHz, using DMSO-d6 as the solvent. Mass spectra were recorded on an Agilent Technologies 622 spectrometer (Agilent Technologies, Santa Clara, CA, USA). UV/vis spectra were acquired on a Shimadzu UV-2550 spectrophotometer (Shimadzu, Beijing, China). Fluorescence measurements were performed on an Agilent Cary Eclipse fluorescence spectrophotometer (Agilent Technologies, Santa Clara, CA, USA).

2.2. Synthesis

The synthetic route to Probe 1 is shown in Scheme 1. 1.5 g (4.93 mmol) Compound 2, synthesized following the literature procedures [30], was mixed with phenanthrene-9, 10-dione (1.03 g, 4.93 mmol), and ammonium acetate (7.4 g, 98 mmol) in 63 mL acetic acid, and heated to reflux under nitrogen atmosphere for 16 h. The mixture was then cooled to room temperature and poured into H2O (100 mL), and the precipitate thus formed was filtered, washed with water and then dried under vacuum. The crude product obtained was purified via column chromatography (300–400 mesh silica gel), CH2Cl2/AcOEt, 4/1, v/v) to produce the desired product (1.263 g, 53% yield). 1H NMR (DMSO-d6, 600 MHz): δ = 8.77 (d, J = 8.4 Hz, 3H), 8.22 (d, J = 6 Hz, 2H), 7.91 (d, J = 7.2 Hz, 1H), 7.64 (t, J = 7.2 Hz, J = 7.2 Hz, 4H), 7.59–7.55 (m, 4H), 7.52 (t, J = 7.2 Hz, J = 7.8 Hz, 1H), 7.31–7.25 (m, 4H), 6.99 (d, J = 7.2 Hz, 1H), 4.08 (s, 1H), 2.49 (d, J = 1.8 Hz, J = 1.8 Hz, 4H). (Figure S1, Supplementary Information). 13C NMR (DMSO-d6, 150 MHz) δ 141.34, 130.39, 130.02, 129.50, 128.79, 128.44, 127.40, 127.28, 127.22, 126.99, 126.93, 125.01, 124.95, 123.73, 121.52, 48.49 (Figure S2, Supplementary Information). MALDI-TOF MS: m/z calculated for C33H25N5: 491.2110; found: 491.2141 (Figure S3, Supplementary Information).

2.3. Spectral Measurements

Distilled water was used for preparing solutions throughout the experiments. Solutions of all the metal ions used (Cu2+, Hg2+, Ca2+, Ba2+, Cd2+, Zn2+, Pb2+, Mg2+, Co2+, Fe2+ and Mn2+) were prepared from their nitrate salts. A stock solution (0.5 mM) of Probe 1 in ethanol was prepared, which was then diluted to 10 μM with ethanol. In the spectral titration experiments, 2 mL of Probe 1 solution (10 μM) was placed in a 1 cm quartz cuvette and Cu2+ solution was added gradually by micro-pipette; UV-vis and/or fluorescence spectra were measured before and after the addition of Cu2+. Since the volumes of Cu2+ solution added were minimal (in μL), the slight change in concentration of Probe 1 can be ignored. For fluorescence measurement, the excitation wavelength was set at 270 nm, and the slit widths for excitation and emission were 5 nm/5 nm.

3. Results and Discussion

3.1. UV-Vis Spectral Response of the Binding between Probe 1 and Cu2+

Probe 1 binds effectively with Cu2+ ions through the chelation with N,N-bis(pyridin-2-ylmethyl) benzenamine (Scheme 2). The same chelation was previously reported in a crystalline study of the complex of Cu2+ [29]. The strong complexation affects the original conjugation between the lone pair of electrons on the aniline amine and the π-orbital of 1H-phenanthro [9, 10-d] imidazole. This can be seen from the significant change in the absorption spectrum of Probe 1 as shown in Figure 1a. Upon the addition of a Cu2+ ion, a significant absorption increase was observed for the wavelength region below 260 nm and in the region between 300 and 325 nm, whereas the absorption in the range of 270–300 nm and 325–345 nm was decreased. Clear isosbestic points can be identified at 269, 300, 328 and 343 nm between the increasing and decreasing bands, indicating the stoichiometric chelation equilibrium shown in Scheme 2.
Along with the absorption change, the fluorescence spectra recorded accordingly also demonstrated a significant change as shown in Figure 1b. The fluorescence quantum yield of Probe 1 in the absence of Cu2+ was determined to be 6.7%, which represents a medium-strength fluorophore suited for being used as a sensor. Upon the addition of a 1:1 molar ratio of Cu2+ ions, the fluorescence intensity was quenched by 74%. Interestingly, the fluorescence quenching was dominated by the emission in the shorter wavelength region, while the emission at longer wavelengths (above 437 nm) was actually increased slightly, implying the formation of a charge transfer (CT) transition between the 1H-phenanthro [9, 10-d] imidazole moiety and the Cu2+ complex. The fluorescence quenching observed was likely due to the photoinduced electron transfer from the lowest unoccupied molecular orbital (LUMO) of 1H-phenanthro [9, 10-d] imidazole to the Cu2+ ion.

3.2. Stoichiometric Ratio of Probe 1-Cu2+ Complex

The sensitive fluorescence quenching of Probe 1 by the Cu2+ ions provided a way to determine the chelation stoichiometry between the two species simply through a Job plot approach, as shown in Figure 2 [31]. A Job plot is commonly used to determine the stoichiometry of a binding event between two species in a solution. In this method, the total molar concentrations of the two binding species (here Probe 1 and Cu2+ ions) are held constant, while their molar fractions are varied. An observable variable (here the fluorescence quenching) that is proportional to the complex formation can be plotted against the molar fractions of the binding species. The maximum of the plot corresponds to the stoichiometry of the complex formed by the two binding species. In this study, by fixing the total concentration of Probe 1 and the Cu2+ ions at 10 μM, the molar ratio of the two species was changed from 1:9 to 9:1, and the fluorescence intensity of the mixture was measured at 387 nm under the same conditions. The molar ratio that gives the maximal fluorescence quenching should correspond to the stoichiometry between Probe 1 and Cu2+ ions, ca. 1:1 as indicated in Figure 2. The 1:1 ratio is consistent with the previous reports on the same chelation of N,N-bis(pyridin-2-ylmethyl) benzenamine with Cu2+ ions [29].

3.3. Fluorescence Quenching Selectivity

To examine the fluorescence quenching selectivity of Probe 1 towards Cu2+, comparative experiments were conducted for the same quenching but in the presence of 10 other common metal ions, as shown in Figure 3 and Figures S5 and S6. Compared to the efficient quenching by Cu2+ (far left bar in the figure), all other metal ions gave a much lower degree of quenching under the same experimental conditions. Adding the same concentration of Cu2+ to each of the 10 solutions containing the different metal ions resulted in dramatic fluorescence quenching at the same level as that observed for the solution containing only Cu2+ as the quencher. These results indicate good selectivity for Probe 1 towards Cu2+ when used as a fluorescence sensor. The high selectivity is due to the strong chelation interaction between Probe 1 and Cu2+ as shown in Scheme 2, as well as the photoinduced electron transfer thus enabled between the two species. Although Probe 1 also binds to other metal ions such as Co2+, Zn2+, Cd2+, these ions do not possess a strong electron-accepting capability as Cu2+ does, and thus can hardly induce effective photoinduced electron transfer. The stronger electron acceptability of Cu2+ can be seen from its higher standard reduction potential, +0.34 V, much higher than those of Co2+, Zn2+, Cd2+, −0.29, −0.70, −0.40 V, respectively.

3.4. Detection Limit

Figure 4 shows the fluorescence intensity of Probe 1 (10 μM in ethanol) as a function of the concentration of Cu2+ (plotted here as the ratio of [Cu2+]/[1]). All the data points can be fitted well into a linear relationship, giving the equation as marked in the plot (with a slope of 368.49). Following the common practice in analytical chemistry, the detection limit can be calculated by defining the lowest detectable signal as three times the standard deviation of the intensity measurement. In this study, the standard deviation of the intensity measurement was 0.34, and three times that gives 1.02. This value represents the minimal detectable change in the fluorescence intensity, which corresponds to the lowest detectable value of [Cu2+]/[1] (calculated as 1.02/slope = 2.77 × 10−3). Since the concentration of Probe 1 was kept at 10 μM, the detection limit of Cu2+ was obtained as 2.77 × 10−8 M (or 1.77 ppb). Such a low detection limit is significantly improved, by one to three orders of magnitude, in comparison to the previously reported chemosensors (Figure S7). A low detection limit will be suitable for the trace detection of Cu2+ in blood [32].
In addition to the high sensitivity and selectivity, a fast sensing response was another feature of Probe 1 regarding the detection of Cu2+. Upon the addition of an equivalent amount Cu2+ ions, the fluorescence intensity of Probe 1 (10 μM) in ethanol was quenched rapidly (Figure S4), with a response time estimated to be ca. 10 s (inset of Figure S4). This fast sensing response makes Probe 1 highly suited for real-time monitoring, or portable detection [33], which is not feasible for the traditional analytical methods and many other chemosensors reported before. Moreover, Probe 1 was also proven to have high photostability as shown in Figure S8, wherein the fluorescence of Probe 1 was measured multiple times over 2 h, but no significant decrease in the fluorescence intensity was observed.

4. Conclusions

In conclusion, we have developed an efficient molecular fluorescence sensor, Probe 1, based on phenanthro-imidazole for quick trace-level detection of Cu2+ ions in aqueous solutions. Probe 1 demonstrated sensitive fluorescence quenching upon binding with Cu2+ ions through 1:1 stoichiometric chelation. The detection limit was projected through linear quenching fitting to be as low as 2.77 × 10−8 M (or 1.77 ppb), which is improved by one to three orders of magnitude in comparison to the previously reported chemosensors. The fluorescence sensing response was highly selective towards Cu2+ ions without significant interference from other common metal ions under the same conditions. The sensing response towards Cu2+ ions was also found quickly, on the time scale of seconds. Moreover, high photostability was also proven for Probe 1 by repeatedly measuring the florescence over 2 h. The combination of all these features makes Probe 1 an ideal sensor for the portable, real-time detection of copper ions.

Supplementary Materials

The following are available online at https://www.mdpi.com/1424-8220/17/1/35/s1, Figure S1: 1H NMR (600 MHz) spectrum of compound 1 in d-DMSO; Figure S2: 13C NMR (150 MHz) spectrum of compound 1 in d-DMSO; Figure S3: MALDI/TOF MS spectrum of compound 1; Figure S4: Fluorescence intensity measured at 387 nm for probe 1 in ethanol (10 μM) as a function of time upon addition of Cu2+ (10 μM). Exponential fitting of the fluorescence intensity decrease gives a response time of ca. 10 s; Figure S5: Fluorescence spectra of probe 1 in ethanol (10 μM) in the absence and presence of various metal ions (10 μM); Figure S6: Fluorescence spectra of probe 1 in ethanol (10 μM) in the absence and presence of various metal ions (10 μM) plus 10 μM of Cu2+; Figure S7: Comparison of the detection limit of Probe 1 with the literature reported detection limits of other sensors. Reference # marked in the horizontal axis are the same as cited in the main context; Figure S8: Fluorescence intensity measured at the main peak of probe 1 in ethanol (10 μM) for nine consecutive times over 2 h.

Acknowledgments

This work was financially supported by the Qinghai Science & Technology Department of China (Grant No. 2016-HZ-806), the National Natural Science Foundation of China (Grant No. 21362027).

Author Contributions

Xingliang Liu designed and synthesized Probe 1; Dandan Cheng carried out the majority of the experiments and wrote the article; Hongzhi Yang helped with and advised on the experiments; Tian Zhang did part of the experiments with the help of Dandan Cheng; Aixia Han was responsible for the whole work; Ling Zang helped supervise the research design and manuscript editing.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Trapaidze, A.; Hureau, C.; Bal, W.; Winterhalter, M.; Faller, P. Thermodynamic study of Cu2+ binding to the DAHK and GHK peptides by isothermal titration calorimetry (ITC) with the weaker competitor glycine. J. Biol. Inorg. Chem. 2012, 17, 37–47. [Google Scholar] [CrossRef] [PubMed]
  2. Hötzer, B.; Ivanov, R.; Brumbarova, T.; Bauer, P.; Jung, G. Visualization of Cu2+ uptake and release in plant cells by fluorescence lifetime imaging microscopy. FEBS J. 2012, 279, 410–419. [Google Scholar] [CrossRef] [PubMed]
  3. Ghaedi, M.; Tavallali, H.; Keshavarz, M.; Niknam, K. Determination of Copper and Zinc Ions by Flame-AAS After Preconcentraction Using Sodium Dodecyl Sulfate Coated Alumina Modified with 3-((1H-Indol-3-yl)-3,4,5-trimethyl)-1H-indole. Chin. J. Chem. 2009, 27, 2066–2072. [Google Scholar] [CrossRef]
  4. Yang, X.; Wang, E. A Nanoparticle Autocatalytic Sensor for Ag+ and Cu2+ Ions inAqueous Solution with High Sensitivity and Selectivity andIts Application in Test Paper. Anal. Chem. 2011, 83, 5005–5011. [Google Scholar] [CrossRef] [PubMed]
  5. Jiang, X.C.; Yu, A.B. Silver Nanoplates: A Highly Sensitive Material toward InorganicAnions. Langmuir 2008, 24, 4300–4309. [Google Scholar] [CrossRef] [PubMed]
  6. Jiang, X.C.; Yu, A.B. Low Dimensional Silver Nanostructures: Synthesis, Growth Mechanism, Properties and Applications. J. Nanosci. Nanotechnol. 2010, 10, 7829–7875. [Google Scholar] [CrossRef] [PubMed]
  7. Carter, K.P.; Young, A.M.; Palmer, A.E. Fluorescent Sensors for Measuring Metal Ions in Living Systems. Chem. Rev. 2014, 114, 4564–4601. [Google Scholar] [CrossRef] [PubMed]
  8. Masilamany, K.; Ramaier, N. L-Cysteine-capped ZnS quantum dots based fluorescence sensor for Cu2+ ion. Sens. Actuators B Chem. 2009, 139, 104–109. [Google Scholar]
  9. Shyamaprosad, G.; Debabrata, S.; Nirmal, K.D. A New Highly Selective, Ratiometric and Colorimetric Fluorescence Sensor for Cu2+ with a Remarkable Red Shift in Absorption and Emission Spectra Based on Internal Charge Transfer. Org. Lett. 2010, 12, 856–859. [Google Scholar]
  10. Liu, X.J.; Zhang, N.; Bing, T.; Shangguan, D.H. Carbon Dots Based Dual-Emission Silica Nanoparticles as a Ratiometric Nanosensor for Cu2+. Anal. Chem. 2014, 86, 2289–2296. [Google Scholar] [CrossRef] [PubMed]
  11. Chen, W.B.; Tu, X.J.; Guo, X.Q. Fluorescent gold nanoparticles-based fluorescence sensor for Cu2+ ions. Chem. Commun. 2009. [Google Scholar] [CrossRef] [PubMed]
  12. Guo, Z.Q.; Zhu, W.H.; Tian, H. Hydrophilic Copolymer Bearing Dicyanomethylene-4H-pyran Moiety As Fluorescent Film Sensor for Cu2+ and Pyrophosphate Anion. Macromolecules 2010, 43, 739–744. [Google Scholar] [CrossRef]
  13. Hariharan, P.S.; Anthony, S.P. Substitutional group dependent colori/fluorimetric sensing of Mn2+, Fe3+ and Zn2+ ions by simple Schiff base chemosensor. Spectrochim. Acta A 2015, 136, 1658–1665. [Google Scholar] [CrossRef] [PubMed]
  14. Grynkiewicz, G.; Poenie, M.; Tsien, R.Y. A New Generation of Ca2+ Indicators with Greatly Improved Fluorescence Properties. J. Biol. Chem. 1985, 260, 3440–3450. [Google Scholar] [PubMed]
  15. He, G.J.; Guo, D.; He, C.; Zhang, X.L.; Zhao, X.W.; Duan, C.Y. A Color-Tunable Europium Complex Emitting Three Primary Colors and White Light. Angew. Chem. Int. Ed. 2009, 48, 6132–6135. [Google Scholar] [CrossRef] [PubMed]
  16. Huang, J.H.; Xu, Y.F.; Qian, X.H. A red-shift colorimetric and fluorescent sensor for Cu2+ in aqueous solution: Unsymmetrical 4, 5-diaminonaphthalimide with N-H deprotonation induced by metal ions. Org. Biomol. Chem. 2009, 7, 1299–1303. [Google Scholar] [CrossRef] [PubMed]
  17. Madhu, S.; Ravikanth, M. Boron-Dipyrromethene Based Reversible and Reusable Selective Chemosensor for Fluoride Detection. Inorg. Chem. 2014, 53, 1646–1653. [Google Scholar] [CrossRef] [PubMed]
  18. Lin, K.K.; Wu, S.C.; Hsu, K.M.; Hung, C.H.; Liaw, W.F.; Wang, Y.M. A N-(2-Aminophenyl)-5-(dimethylamino)-1-naphthalenesulfonic Amide (Ds-DAB) Based Fluorescent Chemosensor forPeroxynitrite. Org. Lett. 2013, 16, 4242–4245. [Google Scholar] [CrossRef] [PubMed]
  19. Hu, B.; Hu, L.L.; Chen, M.L.; Wang, J.H. A FRET ratiometric fluorescence sensing system for mercury detection and intracellular colorimetric imaging in live Hela cells. Biosens. Bioelectron. 2013, 49, 499–505. [Google Scholar] [CrossRef] [PubMed]
  20. Goswami, S.; Maity, S.A.; Maity, A.; Maity, A.K.D.; Saha, P.A. A FRET-based rhodamine–benzimidazole conjugate as a Cu2+-selective colorimetric and ratiometric fluorescence probe that functions as a cytoplasm marker. RSC Adv. 2014, 4, 6300–6305. [Google Scholar] [CrossRef]
  21. Zhang, X.; Shirashi, Y.; Hirai, T. Cu(II)-Selective Green Fluorescence of a Rhodamine-Diacetic Acid Conjugate. Org. Lett. 2007, 9, 5039–5042. [Google Scholar] [CrossRef] [PubMed]
  22. Grasso, G.I.; Gentile, S.; Giuffrida, M.L.; Satriano, C.; Sgarlata, C.; Sgarzi, M.; Tomaselli, G.; Arena, G.; Prodi, L. Ratiometric fluorescence sensing and cellular imaging of Cu2+ by a new water soluble trehalose-naphthalimide based chemosensor. RSC Adv. 2013, 3, 24288–24297. [Google Scholar] [CrossRef]
  23. Boiocchi, M.; Fabbrizzi, L.; Licchelli, M.; Sacchi, D.; Vazquez, M.; Zampa, C. A two-channel molecular dosimeter for the optical detection of copper (II). Chem. Commun. 2003, 21, 1812–1813. [Google Scholar] [CrossRef]
  24. Royzen, M.; Dai, Z.; Canary, J.W. Ratiometric Displacement Approach to Cu (II) Sensing by Fluorescence. J. Am. Chem. Soc. 2005, 127, 1612–1613. [Google Scholar] [CrossRef] [PubMed]
  25. Martinez, R.; Espinosa, A.; Tarraga, A.; Molina, P. New Hg2+ and Cu2+ Selective Chromoand Fluoroionophore Based on a Bichromophoric Azine. Org. Lett. 2005, 7, 5869–5872. [Google Scholar] [CrossRef] [PubMed]
  26. An, R.B.; Zhang, D.T.; Chen, Y.; Cui, Y.Z. A “turn-on” fluorescent and colorimetric sensor for selective detection of Cu2+ in aqueous media and living cells. Sens. Actuators B Chem. 2016, 222, 48–54. [Google Scholar] [CrossRef]
  27. Wang, H.L.; Zhou, G.D.; Chen, X.Q. An iminofluorescein-Cu2+ ensemble probe for selective detection of thiols. Sens. Actuators B Chem. 2013, 176, 698–703. [Google Scholar] [CrossRef]
  28. Huang, J.G.; Liu, M.; Ma, X.Q.; Dong, Q.; Ye, B.; Wang, W.; Zeng, W.B. A highly selective turn-off fluorescent probe for Cu(II) based on a dansyl derivative and its application in living cell imaging. RSC Adv. 2014, 4, 22964–22970. [Google Scholar] [CrossRef]
  29. Almesåker, A.; Bourne, S.A.; Ramon, G.; Scotta, J.L.; Strauss, C.R. Coordination chemistry of N,N,4-tris(pyridin-2-ylmethyl)aniline: A novel flexible, multimodal ligand. CrystEngComm 2007, 9, 997–1010. [Google Scholar] [CrossRef]
  30. Peng, X.J.; Du, J.J.; Fan, J.L.; Wang, J.Y.; Wu, Y.K.; Zhao, J.Z. A Selective Fluorescent Sensor for Imaging Cd2+ in Living Cells. J. Am. Chem. Soc. 2007, 129, 1500–1501. [Google Scholar] [CrossRef] [PubMed]
  31. Zhao, W.Q.; Liu, X.L.; Lv, H.T.; Fu, H.; Yan, Y.; Huang, Z.P.; Han, A.X. A phenothiazine–rhodamine ratiometric fluorescent probe for Hg2+ based on FRET and ICT. Tetrahedron Lett. 2015, 56, 4293–4298. [Google Scholar] [CrossRef]
  32. Huang, L.; Cheng, J.; Xie, K.; Xi, P.; Hou, F.; Li, Z.; Xie, G.; Shi, Y.; Liu, H.; Bai, D.; et al. Cu2+-selective fluorescent chemosensor based on coumarin and its application in bioimagin. Dalton Trans. 2011, 40, 10815–10817. [Google Scholar] [CrossRef] [PubMed]
  33. Han, A.X.; Liu, X.H.; Prestwich, G.D.; Zang, L. Fluorescent sensor for Hg2+ detection in aqueous solution. Sens. Actuators B Chem. 2014, 198, 274–277. [Google Scholar] [CrossRef]
Scheme 1. Synthetic route for fluorescent Probe 1.
Scheme 1. Synthetic route for fluorescent Probe 1.
Sensors 17 00035 sch001
Scheme 2. Chelation with Cu2+ quenches the fluorescence of Probe 1 via intramolecular CT.
Scheme 2. Chelation with Cu2+ quenches the fluorescence of Probe 1 via intramolecular CT.
Sensors 17 00035 sch002
Figure 1. UV/vis absorption (a) and fluorescence (b) spectra of Probe 1 in ethanol (10 μM) upon addition of varying concentrations of Cu2+ ions (0–1 equiv).
Figure 1. UV/vis absorption (a) and fluorescence (b) spectra of Probe 1 in ethanol (10 μM) upon addition of varying concentrations of Cu2+ ions (0–1 equiv).
Sensors 17 00035 g001
Figure 2. Job plot of the binding between Probe 1 and Cu2+ in ethanol, with the total concentration of the two kept constant at 10 μM. F0 and F are fluorescence intensities measured at 387 nm in the absence and presence of Cu2+, respectively.
Figure 2. Job plot of the binding between Probe 1 and Cu2+ in ethanol, with the total concentration of the two kept constant at 10 μM. F0 and F are fluorescence intensities measured at 387 nm in the absence and presence of Cu2+, respectively.
Sensors 17 00035 g002
Figure 3. Fluorescence intensity measured at 387 nm for Probe 1 in ethanol (10 μM) in the absence of metal ions (Green), and in the presence of 10 μM various metal ions (Blue); 10 μM Cu2+ was added to each of the 11 solutions and the fluorescence intensity was measured again for comparison (Red).
Figure 3. Fluorescence intensity measured at 387 nm for Probe 1 in ethanol (10 μM) in the absence of metal ions (Green), and in the presence of 10 μM various metal ions (Blue); 10 μM Cu2+ was added to each of the 11 solutions and the fluorescence intensity was measured again for comparison (Red).
Sensors 17 00035 g003
Figure 4. Fluorescence intensity measured at 387 nm for Probe 1 in ethanol (10 μM) as a function of the concentration of Cu2+ (0–1 equiv.). Inset shows the linear fitting result of the data points.
Figure 4. Fluorescence intensity measured at 387 nm for Probe 1 in ethanol (10 μM) as a function of the concentration of Cu2+ (0–1 equiv.). Inset shows the linear fitting result of the data points.
Sensors 17 00035 g004

Share and Cite

MDPI and ACS Style

Cheng, D.; Liu, X.; Yang, H.; Zhang, T.; Han, A.; Zang, L. A Cu2+-Selective Probe Based on Phenanthro-Imidazole Derivative. Sensors 2017, 17, 35. https://doi.org/10.3390/s17010035

AMA Style

Cheng D, Liu X, Yang H, Zhang T, Han A, Zang L. A Cu2+-Selective Probe Based on Phenanthro-Imidazole Derivative. Sensors. 2017; 17(1):35. https://doi.org/10.3390/s17010035

Chicago/Turabian Style

Cheng, Dandan, Xingliang Liu, Hongzhi Yang, Tian Zhang, Aixia Han, and Ling Zang. 2017. "A Cu2+-Selective Probe Based on Phenanthro-Imidazole Derivative" Sensors 17, no. 1: 35. https://doi.org/10.3390/s17010035

APA Style

Cheng, D., Liu, X., Yang, H., Zhang, T., Han, A., & Zang, L. (2017). A Cu2+-Selective Probe Based on Phenanthro-Imidazole Derivative. Sensors, 17(1), 35. https://doi.org/10.3390/s17010035

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop